4. Technical dataCheck the technical data based on the table below.Installation manualGastype:Indirect heating functionalityDirect heat outputIndirect heat outputSpace heating emissions NOxHeat outputNominal heat outputMinimum heat output (indicative)Technical dataNominal heat input (Hs)Nominal heat input (Hi)Consumption maxConsumption minBurner pressure maxBurner pressure minMain burner injectorLow setting injectorEfficiency class (EN613)Useful efficiency (NCV)**Useful efficiency at nominal heat outputUseful efficiency at minimum heat output (indicative)Auxiliary electricity consumptionAt nominal heat outputAt nominal heat outputIn standby modePermanent pilot flame power requirementPilot flame power requirement (if applicable)Energy efficiencyEnergy efficiency indexEnergy efficiency classSymbolPnomPminηth,nomηth,minelmaxelminelSBPpilotEEIG25/G25.3*No9,3-100,69,31,913,211,9139632319,24,92x Ø1,622x Ø1,40A****191,884,50,02360,01250,0026-91AG31No9,8-75,39,82,413,412,349412725,66,01x Ø1,002x Ø1,051x Ø1,10A****187,785,30,02360,01250,0026-87BG20No10,0-121,810,02,314,012,6130833915,34,92x Ø1,622x Ø1,40A****192,184,40,02360,01250,0026-92AUnitkWkWmg/kWhinput(GCV)kWkWkWkWL/hL/hmbarmbarmmmm%%kWkWkWkWG30No11,4-91,811,42,515,314,143110625,45,81x Ø1,002x Ø1,051x Ø1,10A****188,182,90,02360,01250,0026-88AType of heat output / room temperature controlSingle stage heat output, no room temperature control Two or more manual stages, no room temperature controlWith mechanic thermostat room temperature controlWith electronic room temperature controlWith electronic room temperature control plus day timerWith electronic room temperature control plus week timerOther control optionsRoom temperature control, with presence detectionRoom temperature control, with open window detectionWith distance controle optionNoNoNoYesYesYesYes***Yes***YesMaestro 100 RCHBuilt-inClosed combustionC11, C31, C91, C12, C32*****I2E, I2E+, I2EK, I2ELL, I2H, II2H3+, II2E+3+, II2H3B/P, II2E3B/P, II2EK3B/P200/130DRU LAS ES-I 200/130, DRU LAS ES-E 200/150/100,DRU LAS ES-I 150/100, DRU PV-I 100/60Separated ignition / ionization plugsYes150°C700 mm / 500 mmV-in: 80 cm2 (Eco Glow; 2x 80 cm2) /V-out: 200 cm2* This appliance is suitable for G25.3 with the composition according NTA 8837. ** System efficiency. *** To be used by means of home automation. **** Adjusting screw. *****Categories C12 and C32 only in combination with DRU PV-1 100/60 (PowerVent®).Model identifier(s)Type of applianceCombustionTypeCategorieConcentric appliance connectionApplicable concentric systemsFlame protection versionPressure equalisationMax. temp. outer tube concentric system