3.3 Precautions / safety instructions during
installation
Carefully observe the following precautions/safety
regulations:
you should only install and maintain the appliance if you
are a competent installer in the fi eld of atmospheric gas-
red heating;
do not make any changes to the appliance;
use non combustible and heat-resistant materials for the
chimney breast, including the top of the chimney breast,
the material in the chimney breast and the back wall
against which the appliance will be placed;
take suffi cient measures to prevent temperatures of a wall
behind the chimney breast becoming too high, including
the materials and/or objects behind the wall;
comply with the minimum required internal measure-
ments of the chimney breast;
ventilate the chimney breast by means of the ventilation
holes, which will form a combined passage of at least
200 cm
2
;
only use the fl ue gas discharge / combustion air supply
system supplied by DRU;
do not place the appliance too tightly against the back
wall;
make sure the space between the adjustable feet is kept
free;
do not cover the appliance and/or do not wrap it in an
insulation blanket or any other material;
make sure that combustible objects and/or materials have
a distance from the appliance of at least 500 mm
only ever use the supplied wood set;
place the wood set exactly as described;
make sure the pilot burner and the space around it is kept
free;
make sure thermocouple 2 and the space around it are
kept free;
make sure there is no dirt in gas pipes and connections;
mount a gas tap directly next to the appliance;
check the connections for gastightness before using the
appliance;
use heat resistant electrical wiring;
place the electrical wiring in such a way that they are free
from the appliance;
replace torn or broken panes;
avoid blocking of the pressure equalization hatch(es) on
top of the appliance;
check whether the pressure equalization hatch(es) fi t well
onto the sealing surface, prior to building in the appliance;
do not ignite the appliance until it is fully installed.
4. Instructions
Observe the following items during installation in order to
guarantee a proper and safe operation of the appliance:
mount the control box as low as possible. The control
box is not part of the appliance's standard equipment and
is available at your dealer;
avoid that the ignition cable runs over the receiver;
avoid that the ignition cable touches or crosses the
antenna;
make sure the ignition cable cannot come into contact
with other wires;
avoid that the ignition cable runs alongside metal parts, in
order to prevent weakening of the spark;
properly fi nish the edges in case of a tight construction;
do not apply plaster on or over the fl anges;
avoid damages when removing/placing the pane;
clean the pane before you use the appliance, in order to
prevent dirt from burning in the glass;
make sure that the wires of thermocouple 2 cannot come
into contact with hot parts.
5. Removing the packaging
Note the following items when removing the packaging:
Check the appliance for damages during transport.
If necessary, contact DRU Service.
After removing the packaging, you should have the following
components:
- Socket spanner; you will fi nd it in the space between the
assembly frame and the combustion chamber;
- Decorative strips; you will fi nd them in the abovementi-
oned space as well;
After removing the pane, you can take the wood set and
the box with parts out of the combustion chamber.
!Caution Avoid damages when removing/placing the
pane.
Remove the pane as described in section 6.10.1.
Remove the wood set from the combustion chamber.
Remove the box containing parts from the combustion
chamber.
In appendix 1/ table 5 you can see which parts you should
have after removing the packaging.
Contact DRU Service if you do not have all the parts after
you fi nished removing the packaging.
Dispose packaging in accordance with local regulations.
6. Installation
!Caution Install the appliance in the order described
in this chapter.
6.1 Regulations
Observe the applicable (installation) regulations.
Observe the regulations/instructions in this manual.
6.2 Type of gas
The data plate indicates for which type of gas, gas pressure
and for which country this appliance is intended. The data
plate is connected to a chain. It should remain connected to
the chain.
Check whether the appliance is suitable for
the type of gas and the gas pressure used at
the location.
Caution
29

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw DRU GLOBAL 70 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van DRU GLOBAL 70 in de taal/talen: Nederlands, Engels als bijlage per email.

De handleiding is 7,1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van DRU GLOBAL 70

DRU GLOBAL 70 Gebruiksaanwijzing - Deutsch - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info