Start
2.01 Can pilot be lit?
2.03 Only one spark?
2.02 Sparking?
2.09 Ignitionprocedure
- Oval knob on gas control is on
"MAN". Set to "ON" and restart.
Retardedignitionofmain
burner(s)
Gas to main burner opens ca. 3-5
seconds after servo motor,
operating the gas valve, starts
running (sound of motor!). After
this the main burner is to ignite (at
least partially) within 10 seconds
and not with a firm noise WHOOF.
If not: no or delayed cross lighting
of main burner.
Hazardoussituation.
Stop ignition procedure straight
away and first check for:
- Position of logs or pebbles.
- Burner holes (locally) blocked.
Remove vermiculite dust.
- Vermiculite missing.
- Chips on burner.
- Vermiculite not distributed
evenly across burner(s).
PowerVent®(ifpresent)
Burner does not light. Consult
PowerVent® installation manual
how to carry out the checks below.
Check:
- 230 V to fan controller unit and
fan.
- Silicon pressure measurement
hoses:
- swapped;
- leaking or barred.
- Pressure difference set too high.
- Resistance of flue system too
high:
- adjustment (of appliance
damper and air inlet guides);
- flue length or number of bends
too large;
- dirty (e.g. cobwebs).
- Operation of the fan.
- Operation of solenoid gas valve.
- Operation of fan controller unit.
- Operation of pressure
measurement gauge.
2.11 Nopropercrosslighting
ofmainburner(s).
Go to box 2.09 and take
actions act as described for
'retarded ignition of main
burner'.
2.06 Pilot can be lit.
Does it stay alight?
2.10 Do(es) main burner(s)
ignite smoothly and across
its/their full length after first
ignition by pilot burner?
2.08 Does main burner
ignite immediately?
2.04 Check:
Receiver
- Replace missing, weak or
rechargeable batteries (not enough
power to open thermoelectric
valve).
Presenceofgasonpilotburner
Check pilot on presence of gas at
normal ignition cycle or in Manual
Mode (turn oval knob on gas control
to MAN and keep safety shut off
valve opened with a screwdriver) and
ignite pilot with a lighter.
- Pilot flame not on: Step 1.
- Pilot flame on: Step 2.
Step1:Pilothasnogas
Check:
- Gas tap open?
- Gas at gas control (line pressure at
measuring point on gas control).
- Gas flowing out of gas control? (by
loosening pilot tube at gas control).
If not: check adjustment screw pilot
flame (under black cover): sealing
not to be broken.
Sealing broken: screw should be
fully open.
- Blocking of pilot tube (kink or dirt).
- If this does not help: replace gas
control.
Step2:Pilothasgas,butno
ignition
- Electrode with 90°bended tip:
bend tip 1 mm higher.
- Spark too weak (thin and reddish).
Act as if 'no spark' in box 2.05 and
perform actions described for
ignition cable and ignition
electrode.
- Pilot flame too weak (dirty).
Remove injector (remove gland nut
and the pilot tube). See that it does
not fall away. Clean with
compressed air.
Rectify. Retry.
2.05 Check:
Ignitioncable
- Present and connected.
- Being free from metal parts or
concrete.
- Too long: cut away all excessive
length at receiver end, and
reconnect.
- Shorting out to earth: replace
ignition cable.
- Spark in wrong position:
- slide rubber sleeve on ignition
cable over ceramic of electrode.
- Replace electrode if neccessary.
Ignitionelectrode
- Straight electrode:
- oxidation (roughen electrode
with file or sand paper);
- position (4 mm from pilot burner).
- Cracks in ceramic (not always
visible): replace electrode.
Startingprocedure
After switching off/going out the
remote is locked for 120 sec. (older
versions 60 sec).
Wait 2 minutes before reigniting.
2.07
Pilotoutwhenservomotorstarts
torun?Checkthethermocouple
system.
- Measure thermocouple voltage in
mV just after servomotor starts to
run and the voltage goes down.
- Measure between red dot on
receiver and earth point on gas
control (fig. 42).
- 0 mV
- 2-3 mV
- 3-5 mV
- 6 mV and higher
- Requirement: after rectification
actions thermocouple voltage
should be 6 mV at least, just after
motor starts running!
Voltage0mV
- Thermocouple defective. Check by
replacing or measuring voltage at
end whilst heating (tip: with a
lighter).
- Short circuiting or interruptions in
circuit:
Check:
- thermocouple tight in
interruptor;
- interruptor tight in gas control;
- black wires (yellow/red end)
connected to interruptor +
receiver;
- interruptor (mount
thermocouple directly in gas
control and ignite in Manual Mode
(see 2.04).
If pilot stays on: interruptor
defective.
Voltage2-3mV
- Check pilot flame.
Too small:
- pilot dirty.
Clean up (see 2.04).
- check for pilot gas tube
tightness;
- pilot tube kinks or dirt inside;
- line pressure too low.
- Tip: thermo couple not in (correct!)
pilot flame.
Bend into flame.
Voltage3-5mV
- Appliance may work, but is too
critical.
Perform actions as described for
2-3 mV.
Voltage6mVandhigher
Voltage OK, so different cause.
- Receiver defective. Check by
dismounting black-red and yellow
control cables from receiver and
link together. Ignite fire in Manual
Mode (see 2.04). Pilot stays on:
receiver defective.
- Gas control defective if receiver is
not defective. Replace gas control.
yes
no
yes yes
no
no
no
no no
Fires with electronic ignition, fault finding: Ignition and burning
Appendix1diagnosisofmalfunctions
GB20
2.03a
- Loosen and retighten
earthing screw on gas
control.
- If this does not work:
replace receiver.
yes
yes
20

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

DRU-Diablo-Next

Zoeken resetten

  • Wij hebben een dru diablo uit 2000 heeft het erg goed gedaan alleen nu vonkt hij niet meer,hebben een nieuwe bougie gekregen en die doet het ook niet.wat zou de oorzaak kunnen zijn,zoms vonkt hij wel en dan doet hij het goed. Gesteld op 6-9-2023 om 12:32

    Reageer op deze vraag Misbruik melden
  • wanneer ik met het gasregelblok te haard wil activeren gebeurt er niets Gesteld op 29-10-2020 om 14:46

    Reageer op deze vraag Misbruik melden
  • Hoe kan ik de ruiten aan de binnenkant schoonmaken, hoe kom ik daarbij? Gesteld op 25-6-2016 om 12:40

    Reageer op deze vraag Misbruik melden
  • de aftandbediening heeft nieuwe baterijen. Nu wil hij wel dimmen maar niet feller branden
    Ook de batterijen in de ontvanger zijn vervangen
    Gesteld op 16-3-2016 om 14:07

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw DRU Diablo Next bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van DRU Diablo Next in de taal/talen: Engels als bijlage per email.

De handleiding is 4.59 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van DRU Diablo Next

DRU Diablo Next Installatiehandleiding - Nederlands - 36 pagina's

DRU Diablo Next Gebruiksaanwijzing - Nederlands - 20 pagina's

DRU Diablo Next Gebruiksaanwijzing - Nederlands - 16 pagina's

DRU Diablo Next Installatiehandleiding - Deutsch - 36 pagina's

DRU Diablo Next Gebruiksaanwijzing - Deutsch - 20 pagina's

DRU Diablo Next Gebruiksaanwijzing - English - 20 pagina's

DRU Diablo Next Gebruiksaanwijzing - Français - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info