810299
12
Verklein
Vergroot
Pagina terug
1/56
Pagina verder
Foreword
Dear Customer,
We would like to thank you for buying this DRU prod-
uct. Our products have been designed and produced to
meet the highest possible quality, performance and safety
requirements, allowing you to enjoy years of problem-free
use.
In this booklet you will find instructions for the installation
and use of your new appliance. Please read these instruc-
tions and the manual carefully to familiarize yourself with
the appliance. If you require any further support, please do
not hesitate to contact your supplier.
Unpacking
Once the heater has been unpacked, all packaging should
be disposed of in the regular manner.
Connection
This appliance should be connected by a registered installer.
INSTRUCTIONS FOR INSTALLATION
Type of gas
This appliance can only be used and is only suitable for the
country and the type of gas mentioned on the type iden-
tification tag. Please check that the local gas and pressure
correspond with the specifications on the type identifica-
tion tag. All regulations regarding gas installation, includ-
ing any local regulations, must be observed at all times.
Installation and maintenance of the appliance should be
performed by a professional certified expert with proven
knowledge and demonstrable competence in this field. A
professional expert takes all technical aspects such as heat
output and gas connection into account, as well as the flue
gas discharge requirements. The installation manual will
give you the information you need to install the appliance
in such a way that it will operate properly and safely. If the
installation instruction is not clear, national/local regula-
tions must be observed.
To operate the heater suitable for natural gas on propane,
it should be converted by a competend person. A conver-
sion set can be ordered through your
supplier.
Important
• Keep curtains and any other flammable materials at least
50cm away form the appliance.
• Caution! Touching the heater when hot can cause burns
and blisters!
• The appliance should be installed and maintained by a
registered installer.
• Do not install any so-called dust filter on or under the
casing.
• Do not hang wet clothes and towels etc. on the heater
to dry.
• The appliance was designed for atmospheric and heating
purposes. This means that all visible surfaces, including the
glass pane, can become hotter than 100C°. It is recom-
mended to always place a protective grating in front of
the appliance when there are children, elderly people or
handicapped persons in the same room as the appliance.
If it is possible that vulnerable people are regularly present
in the room with no supervision, a fixed guard should be
mounted around the appliance.
• When installing the appliance, check the air circulation
(by convection) around the thermostat sensor. If there is
a lack of air circulation, the sensor must be moved to a
position with sufficient air circulation for correct opera-
tion of the appliance.
General
The appliance can be mounted either on a wall of incombu-
stible material (e.g. stone or concrete) or on a wall of com-
bustible material (e.g. wood).
Art 2-01,3-01 and 4-01 on propane (G31) can be placed
in vehicles pulling mobile units, provided the following is
observed:
When the appliance is working, the mobile unit must be
standing still;
When the vehicle pulling the mobile unit is being filled
with fuel, the appliance must be switched off;
If glass is broken, switch off the appliance and contact an
installer;
In case of a gas leak, switch off the appliance as well as the
gas supply tap and contact an installer;
Flue gas discharge must remain unobstructed at all times.
Installation to a wall of non-flammable material
(fig. 7, 9, 11, pg. 50-52)
ART Models 2-01, 3-01 and 4-01 can are suitable for
hanging installation only, ART Models 5-01, 6-01, 8-02
and 10-02 are suitable for either hanging or freestanding
installation. Allow at least 1 metre’s clearance above the
heater to enable sufficient heat circulation. When installed
hanging, at least 1 m free space should be kept above the
appliance to allow sufficient heat dissipation.
When intalled standing, the bottom of the mounting sheet
(2) should stand on the floor, this is the minimum height
between the floor and centre of wall duct
(size F. fig 7, 9, 11, pg. 50-52).
The mounting plate (2) serves as a template to mark the
position of the duct. To be able to hang the casing over the
interior, a minimal clearance of 25 mm must be allowed
between the appliance and a windowsill or suchlike. The
minimum clear installation height (Y) required for each of
the various models is listed in the table on page 53.
The standard wall duct
Drill a horizontal hole in the wall, ø E to take the air-supply
pipe. The wall duct should slope at an angle of approx. 2º.
10
INSTRUCTIONS FOR INSTALLATION
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw DRU ART 4-01 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van DRU ART 4-01 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 2.01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info