DIVE-SET MODE: Diving parameters setting.
Once the MODE SET (MODE-S) menu is set in AIR or NITROX mode you can modify the parameters by
accessing the next menu DIVE SET (DIVE-S).
IMPORTANT: If the screen displays the battery icon with a single segment on, the computer MUST NOT
be used. The battery can be replaced by the user, as we shall see in the corresponding chapter
IMPORTANT: Once changing from NITROX SET MODE to AIR SET MODE, the parameters of both Mix1
and Mix2 return to the values 21% (FO2) and 1.4 bar (PO2).
PARTIAL OXYGEN PRESSURE (PO2)
Newton is factory set with a Partial Oxygen Pressure (PO2) value of 1.4 bar both for the air dives and Nitrox
dives with one or two mixtures (Mix1 and Mix2) in order to ensure the maximum safety during any type of dive.
However, the PO2 can only be modified if the computer is set in NITROX SET MODE in values between 1.2 bar
(included) and 1.6 bar (included) with variations of 0.1 bar. In case you need to increase the safety margin of
the dive, it will be possible to set PO2 to lower values, up to a minimum of 1.2 bar.
Mix1 Partial Oxygen Pressure (PO2) setting.
Press the UP button to move up to dive set mode (DIVE-S). Enter in this mode by pressing the Mode button and
the partial oxygen pressure (PO2) indication and the Mix1 indicator will flash. Now press the Mode button
again. The display will show just the highlighted item, flashing together with the corresponding maximum
operating depth. Set the desired values (between 1.2 and 1.6 bar, with variations of 0.1 bar) by pressing the UP
or DOWN button. Confirm the value set by keeping the Mode button pressed for a few seconds until hearing an
acoustic signal to confirm exit from the menu. Keep pressing and holding the Mode button to return to the main
menu (after another acoustic signal). Alternatively, the computer will modify the automatic setting by issuing an
acoustic signal to return then to the main screen.
Mix2 Partial Oxygen Pressure (PO2) setting.
Press the UP button to move up to dive set mode (DIVE-S), enter in this mode by pressing the Mode button.
The indication of the partial oxygen pressure (PO2) and the Mix1 indication will flash. Press the UP button
twice. The word Mix2 will appear together with the PO2 value. Now press the Mode button again. The display
will show just the highlighted item, flashing together with the corresponding maximum operating depth. Set the
desired values (between 1.2 and 1.6 bar, with variations of 0.1 bar) by pressing the UP or DOWN button.
Confirm the value set by keeping the Mode button pressed for a few seconds until hearing an acoustic signal to
confirm exit from the menu. Keep pressing and holding the Mode button to return to the main menu (after
another acoustic signal). Alternatively, the computer will modify the automatic setting by issuing an acoustic
signal to return then to the main screen.
IMPORTANT: the computer maintains the PO2 setting until it is manually reset by the diver on different values
or until the MODE-S menu is set in AIR.
REMARK: By varying the maximum PO2 set and the percentage of oxygen in the FO2 mixture, the computer
indicates the maximum depth which may be reached.
IMPORTANT: The PO2 is set by the manufacturer on the default value of 1.4 bar, for both air dives and Nitrox
dives. This way, the safety of the diver is ensured by following the most conservative values recommended for
sport dives. However, you can select another PO2 value, as indicated in the chapter on Nitrox dives. The value
set will be saved in the computer until the diver resets it or until the MODE-S menu is set in AIR.
NITROX PERCENTAGE OF OXYGEN (FO2)
The percentage of oxygen FO2 can be changed only when the computer is set in SET NITROX MODE. With
this setting you can decide the type of dive: with air (Dive Air Program), with fraction of oxygen at 21%, or using
one or two Nitrox hyper-oxygenated mixtures (Dive Nitrox Program).
Mix1 percentage of oxygen (FO2) setting
To set the correct percentage of Oxygen contained in the Nitrox mixture, press the UP button to move up to the
DIVE-S mode. Enter in this mode by pressing the Mode button. The indication of the partial oxygen pressure
(PO2) and the Mix1 indicator will flash. Press the UP button. The indicator of the percentage/fraction of oxygen
(FO2) will flash. Press the Mode button. The display will show just the highlighted item (FO2), flashing together
with the corresponding maximum operating depth that can vary by pressing the UP or DOWN button of the
device. Once the desired setting is reached (values between 21% and 50% with variations of 1% of O2),
confirm the value set by keeping the Mode button pressed for a few seconds until hearing an acoustic signal to
confirm exit from the menu. Keep pressing and holding the Mode button to return to the main menu (after
another acoustic signal). Alternatively, the computer will modify the automatic setting by issuing an acoustic
Po2 MIX1 - PARTIAL OXYGEN PRESSURE SETTING MIXTURE 1
PO2 MIX2 - PARTIAL OXYGEN PRESSURE SETTING MIXTURE 2
INDEX
9
LONG
BEEP
LONG LONG LONG
BEEP BEEP BEEP
LONG
BEEP
LONG
BEEP
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Cressi NEWTON bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Cressi NEWTON in de taal/talen: Engels als bijlage per email.

De handleiding is 8,29 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info