511355
32
Verklein
Vergroot
Pagina terug
1/56
Pagina verder
32
q Before using your appliance for the first
time, please read these Instructions for
Use carefully. They contain important
information concerning your personal
safety as well as on use and care of the
appliance.
q Please retain the operating and installati-
on instructions for a subsequent owner.
Overheated fat or oil can easily catch
fire. If you are cooking with fat or oil, e.g.
chips, etc., never leave the cooker
unattended.
Do not flambé food directly under the
extractor hood.
Risk of grease filter catching fire due to
flames.
The hotplates must always be covered
with a utensil.
Restrictions apply to the use of the
extractor hood over a solid-fuel burner
(coal, wood, etc.). (See Installation instruc-
tions).
Gas hobs / Gas cookers
Do not use all the gas hotplates simulta-
neously for a prolonged period (max. 15
minutes) at maximum thermal load, otherwi-
se there is a risk of burns if the housing sur-
faces are touched or a risk of damage to
the extractor hood.
If the extractor hood is situated over a gas
hob, operate the hood at maximum setting
if three or more gas hotplates are operated
simultaneously.
Important notes:
q The Instructions for Use apply to several
versions of this appliance. Accordingly,
you may find descriptions of individual
features that do not apply to your
specific appliance.
q This extractor hood complies with all
relevant safety regulations.
q Repairs should be carried out by quali-
fied technicians only.
Improper repairs may put the user at
considerable risk.
Do not use the appliance if damaged.
The appliance is not intended for use by
young children or infirmed persons without
supervision.
Young children should be supervised to
ensure they do not play with the appliance.
If the connecting cable for this applian-
ce is damaged, the cable must be replaced
by the manufacturer or his customer service
or a similarly qualified person in order to
prevent serious injury to the user.
The appliance may be connected to the
mains by a qualified technician only.
Dispose of packaging materials properly
(see Installation instructions).
This extractor hood is designed for
domestic use only.
Light bulbs must always be fitted when
the extractor hood is in use.
Defective bulbs should be replaced
immediately to prevent the remaining bulbs
from overloading.
Never operate the extractor hood with-
out a grease filter.
Before using for the first time
Before using for the first time
Circulating-air mode:
q This requires installation of an activated
carbon filter (see section on filter and
maintenance).
q The activated carbon filter is obtainable
as a special accessory from your
aut-
horized dealer
.
q The corresponding accessory numbers
can be found at the end of these opera-
ting instructions.
q The extractor-hood fan extracts the kit-
chen vapours, which are purified in the
grease filter and activated carbon filter
and then conveyed back into the kit-
chen.
q The grease filter absorbs the grease par-
ticles in the kitchen vapours.
q The activated carbon filter binds the
odorous substances.
If no activated carbon filter is installed,
it is not possible to bind the odorous
substances in the cooking vapours.
Operating modes
Exhaust-air mode:
q The extractor-hood fan extracts the kit-
chen vapours and conveys them through
the grease filter into the atmosphere.
q The grease filter absorbs the solid par-
ticles in the kitchen vapours.
q The kitchen is kept almost free of grease
and odours.
If the extractor hood is operated in
exhaust-air mode at the same time as a
flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
ensure that there is an adequate air
supply
, which the heater requires for com-
bustion.
Safe operation is possible provided that the
partial vacuum in the room in which the
heater is installed does not exceed 4 Pa
(0.04 mbar).
This can be achieved if the combustion air
is able to flow through non-lockable open-
ings, e.g. in doors, windows and in con-
junction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.
If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.
Note: When assessing the overall require-
ment, the combined ventilation system for
the entire household must be taken into
consideration. This rule does not apply to
the use of cooking appliances, such as
hobs and ovens.
Unrestricted operation is possible if the
extractor hood is used in recirculating mode
– with activated carbon filter.
door
filter screen
alighting
lighting/fan switches
Appliance description
Operating modes
Instructions for Use
32

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Constructa CD22130 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Constructa CD22130 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Zweeds als bijlage per email.

De handleiding is 9,07 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info