NAMES AND FUNCTIONS OF PARTS
Interface Box (Equipment) Front Panel
Calibration Indicator [CAL]
* The indicator will light up in green (for about 5 sec-
onds) during image capture.
UART terminal [DATA]
* Connect the serial cable.
RCA terminal [VIDEO]
* Connect the RCA cable.
Interface Box (Equipment) Rear Panel
Power indicator [POWER]
* The indicator will light up in red when power is ON.
USB terminal [USB]
* Connect the USB cable.
Reset switch [RESET]
* This is used when resetting the equipment.
Use a thin rod to press the switch for two or
more seconds.
CAUTION
Do not use this equipment close to a mobile phone or wireless device.
The radio waves from the mobile phone or wireless device may result in noise
and malfunction.
OPERATING METHOD
Start up the equipment.
5.
Start up a notebook PC and install the software on the enclosed application
CD.
6.
Connect the notebook PC and camera ECU to the equipment using the en-
closed cable.
When the USB cable is connected, power is supplied from the PC and the power
indicator lights up in red.
See the cabling instructions and connect the cables between the equipment cor-
rectly.
Advice
7.
Start up the camera ECU.
8.
Perform the operations with the application software installed in the notebook
PC.
See the application software manual in the notebook PC on how to use the appli-
cation software.
Advice
CAUTION
Do not supply power other than the USB bus power to the equipment.
This may result in fire and faults.
Terminating this equipment
1.
Check that access to the equipment and camera ECU has been stopped.
The checks to be conducted when access is stopped are as follows.
3
Check that the calibration indicator (green) has been turned off.
4
Check that serial communication in the application has been stopped.
Advice
2.
Use the application software to disconnect the camera ECU from the equip-
ment.
See the application software manual in the notebook PC on the shutdown proce-
dure.
Advice
3.
Disconnect the USB cable.
The power of the equipment goes OFF and the power indicator (red) goes off.
4.
Disconnect the RCA cable and serial cable.
CAUTION
When disconnecting the USB cable, check that the calibration indicator (green)
goes off.
WIRING AND CONNECTIONS
Preparations
Equipment Enclosed cables
6
Interface Box (Equipment) ...................... 1
Notebook PC (
see below for compatible OS)
...... 1
Camera ECU (Sold Separately) ................. 1
Car-mounted Camera (Sold Separately) .... 4
2
USB Cable ............................................. 1
3
RCA Cable ............................................ 1
4
Serial Cable ........................................... 1
* The notebook PC, camera ECU and car-mounted cameras are sold separately.
* Make sure only the enclosed cables are used.
Notebook PC Compatible OS / Display Resolution
Compatible OS
Windows 7
Professional SP1 32 bit / 64 bit Japanese
version, 32 bit English version
Windows 8.1
Pro 64 bit Japanese version
Display Resolution
XGA (1024 x 768) & above
* Compatible OS are operating systems that have been internally verified to work normally. However, opera-
tions may differ depending on the type of PC and the application software installed in the PC.
How to Connect the Cables
6 SurroundEye Interface Box
(Equipment)
Back Panel
Notebook PC
6 SurroundEye Interface Box
(Equipment) Front Panel
Camera ECU and
car-mounted camera
Connect to the RCA terminal [VIDEO]
3 RCA cable
4 Serial Cable
Connect to the RCA terminal [RCA connectors]
Connect to the UART terminal [4 connectors]
Connect to the UART terminal [DATA]
Connect to the USB port [USB]
* USB B MALE CONNECTER
Connecting to a USB port
* USB A MALE CONNECTER
2 USB cable
Yellow Green
Gray
Gray
Yellow
White
Camera
ECU
TROUBLESHOOTING
Please follow the following troubleshooting procedures in case of any problems.
Consult your dealer if you cannot resolve the issue on your own.
Symptom Reason Solution
There is no power.
The power indicator
is not lit.
The USB cable is
not connected cor-
rectly.
Please see the cabling instructions and
connect the cable correctly.
Image cannot be
captured in the note-
book PC.
The captured image
is distorted.
The RCA cable is
not connected cor-
rectly.
Please see the cabling instructions and
connect the cable correctly.
Serial communication
does not work.
The serial cable is
not connected cor-
rectly.
Please see the cabling instructions and
connect the cable correctly.
The application does
not work.
The various cables
are not connected
correctly.
Please see the cabling instructions and
connect the cable correctly.
The application does
not work.
The micro-computer
is malfunctioning
due to noise etc.
Use a thin rod to press the reset switch
for two or more seconds.
Start up the application again.
The equipment gets
abnormally hot.
The internal elec-
tronic parts may be
faulty.
Unplug the USB cable immediately,
switch off the power supply and con-
sult your dealer.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Clarion UG-2176A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Clarion UG-2176A in de taal/talen: Engels als bijlage per email.

De handleiding is 0,84 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info