Computer instructions for 1104
The supplied computer allows the most convenient training. Every value
relevant to training is displayed in a corresponding window.
From the beginning of the training session, the required time, the current
speed, the approximate calorie consumption, the travelled distance ad the
current pulse rate are displayed. All values are counted from zero upwards.
If you wish to see one value displayed constantly during training, select this
with the „F“ key. If you wish to see these values in constant alternation,
select the „SCAN“ function. The display then changes from one function to
the next at intervals of approx. 6 seconds.
The computer is switched on by briefly pressing the F- key or simply by
beginning training. The computer begins to register and display all values.
To stop the computer, just stop training. The computer stops all
measurements and retains the last attained values. The last attained values in
the functions TIME, CALORIES and KM are stored and training can continue
with these values when training is resumed.
The computer switches of automatically approx. 4 minutes after training
is stopped. All values attained until that time are stored and are displayed
again when training is resumed. It is then possible to continue training from
these values or to reset all functions to zero using the L- key.
Displays:
1. „SPEED“ (KM/H) display:
The current speed is displayed in kilometres per hour. It is not possible to
specify a particular value using the „E“ key. The values last attained by this
function are not stored. (Limit of the display: 99.9 km/h.)
2. „TIME“ (ZEIT) display:
The currently required time is displayed in minutes and seconds. It is possible
to specify a particular value using the „E“ key. If a particular time
has been specified, the remaining time is displayed. When the specified
value is attained, this is indicated by an acoustic signal. The values last
attained by this function are stored. (Limit of the display: 99.59 minutes.)
3. „DIST (KM)“ display:
The current status of the travelled distance is displayed. It is possible to
specify a particular value using the „E“ key. If a particular distance has been
specified, the remaining distance is displayed. When the specified value is
attained, this is indicated by an acoustic signal. The values last attained by
this function are stored. (Limit of the display: 999 km.)
4. „CALORY“ (CAL) display:
The current status of the consumed calories is displayed. It is possible to
specify a particular value using the „E“ key. If a particular consumption
has been specified, the remaining number of calories to be consumed
is displayed. When the specified value is attained, this is indicated by an
acoustic signal. The values last attained by this function are stored. (Limit
of the display: 999 calories.)
5. „KM TOTAL“ (ODO) display:
The current status of the travelled kilometres of all previous training sessions
including current training session is displayed. A particular value cannot be
speci. ed. The values last attained by this function are not stored. (Limit of
the display: 9.999 km.)
6. „PULSE“ display:
The current pulse rate is displayed in beats per minute. It is not possible to
specify a particular value using the „E“ key.
The values last attained by this function are not stored. (Limit of both displays:
40 – 240 pulse beats per minute.)
Note:
For pulse measurement, the two contact surfaces of the pulse measuring
handle unit (84) must be gripped simultaneously. The contact surfaces
should be located centrally in the palms of the hands.
7. „SCAN“ function:
If this function is selected, the current values of all functions are displayed
successively in a constant sequence approx. every 5 seconds.
Keys:
1. „F“ key:
Pressing this key once briefly makes it possible to change from one function
to another, i.e. the respective functions can be selected for which entries
can be made using the „E“ key. The currently selected function is indicated
by an icon in the respective window.
2. „E“ key:
By pressing this key once, it is possible to specify values step by step in the
respective functions. For this, the desired function must firstly be selected
using the „F“ key.
Holding the key pressed activates faster running, which can be stopped
by pressing the key again. When training begins, the specified values are
then counted down to zero.
3. „L“ = Delete:
When this key is pressed briefly, the values chosen with the „F“ key are
reset to zero. If the key is held longer (approx. 3 seconds), all last attained
values are deleted with the exception of the values in the „KM TOTAL“
display.
19

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Christopeit AX1 - 1104 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Christopeit AX1 - 1104 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 1,31 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info