40
Operation of appliances
?
!Summer operation :
(water heater only)
Move the rotary switch on the
control panel to position (c - summer
operation) 40°C or 60°C. The green
(b) and yellow LEDs (g) light up.
The burner shuts down and the
yellow LED (g) is extinguished
once the set water temperature is
reached (40°C or 60°C)
.
!Winter operation:
(Heating with controlled water
temperature).
Move the rotary switch to operatio-
nal setting «e».
Turn the rotary switch (a) to the
desired thermostat setting (1-5).
The green operating LED (b) lights
up and simultaneously displays the
selected room temperature setting.
The yellow LED (g) displays the
water’s heating phase.
The unit selects the power level
required automatically based on the
difference between the temperature
set on the control panel and the
current room temperature. Once
the room temperature set on the
control panel has been reached, the
burner switches back to its lowest
power level and heats the water to
60°C. The yellow LED (g) goes out
once the water temperature has
been reached.
The warm air fan can continue to
run to cool the unit (shutdown
timeout).
Heating without controlled water
temperature.
Move the rotary switch to
operational setting «d».
Turn the rotary switch (a) to the
desired thermostat setting (1-5). The
green operating LED (b) lights up
and simultaneously displays the
selected room temperature setting.
The yellow LED (g - water heating
phase) only lights up when the
water temperature is below 5°C).
The unit selects the power level
required automatically based on the
difference between the temperature
set on the control panel and the
current room temperature. The
burner shuts down once the room
temperature set on the control
panel is reached. The warm-air fan
continues to run slowly as long as
the blowing temperature (on the
unit) is less than 40°C.
The water is also heated automatically
when the water heater is filled. The
water temperature then depends
on the heater output and the time
taken for the heater to reach the
desired room temperature.
Heating with bled water system.
Move the rotary switch to opera-
tional setting «d».
Turn the rotary switch (a) to the
desired thermostat setting (1-5). The
green operating LED (b) lights up
and simultaneously displays the
selected room temperature setting.
The yellow LED (g) only lights up
when the water temperature is
below 5°C!
The unit selects the power level
required automatically based on the
difference between the temperature
set on the control panel and the
current room temperature. The
burner shuts down once the room
temperature set on the control
panel is reached.