Operating & Installation Instructions
charnwood
®
C-SERIES
C O N T E N T S
O P E R AT I N GI N S T R U C T I O N S
INSTALLATIONINSTRUCTIONS
Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FittingTheRiddlingGrate . . . . . . . . . . . . . .
Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
Refuelling . . . . . . . . . . . . . . . . . . . . . . . . . . .
AshClearance . . . . . . . . . . . . . . . . . . . . . . .
ReducedBurning . . . . . . . . . . . . . . . . . . . . .
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . .
ThroatPlate&FluewayClearing . . . . . . . . .
ChimneySweeping . . . . . . . . . . . . . . . . . . . .
TroubleShooting . . . . . . . . . . . . . . . . . . . . .
COAlarm
Ifyouneedfurtherhelp
Health&SafetyPrecautions. . . . . . . . . . . . .
COAlarms. . . . . . . . . . . . . . . . . . . . . . . . . .
Specification . . . . . . . . . . . . . . . . . . . . . . . . .
Chimney. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hearth&FireSurround . . . . . . . . . . . . . . .
ConnectiontoFlues . . . . . . . . . . . . . . . . . .
SootDoors . . . . . . . . . . . . . . . . . . . . . . . . .
UnpackingTheStove . . . . . . . . . . . . . . . . .
PreLightingCheck . . . . . . . . . . . . . . . . . . .
Commissioning . . . . . . . . . . . . . . . . . . . . . .
CleanAirActInformation. . . . . . . . . . . . . .
C-FOURDimensions. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
PartsLists . . . . . . . . . . . . . . . . . . .
4
4
5
5
5
6
6
6
6
7
. . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . 8
9
10
11
11
11
12
12
12
14
15
19
5
9
9
9
13
16
17
18
20
21
22
23
ControllingTheFire
Certification . . . . . . . . . . . . . . . . . . . . . . . .
C-FIVEDimensions
C-SIXDimensions . . . . . . . . . . . . . . . . . . . .
C-SEVENDimensions . . . . . . . . . . . . . . . . .
C-EIGHTDimensions . . . . . . . . . . . . . . . . .
C-FOUR
C-FIVEPartsLists . . . . . . . . . . . . . . . . . . . .
C-SIXPartsLists . . . . . . . . . . . . . . . . . . . . .
C-SEVENPartsLists . . . . . . . . . . . . . . . . . .
C-EIGHTPartsLists . . . . . . . . . . . . . . . . . .
Ref.C-Seriesv204.13
TheseapplianceshavebeenapprovedbyHETASasintermittent
operatingappliancesforburningdryseasonedwoodlogsonly.
HETASapprovaldoesnotcovertheuseofotherfuelseitheraloneor
mixedwithwoodlogsnordoesitcovertheinstructionsforuseof
otherfuels.
Toolrequiredforfittingtheriddlinggrate:
10mmSpanner
Pozidrivscrewdriver
Beforefittingtheriddlinggrate(Fig.1)removethefuelretainerand
thewoodashretainer.Thewoodashretainerisnotrequiredwhen
theriddlinggrateisfitted.
Undothenutontheriddlingblankingholeusinga10mmspanner.
Removethecoverandspacingwasher(ensureyoukeeptheseina
safeplaceasyouwillneedtoreplacethemiftheriddlinggrateis
removed).
Feedtheriddlerrodthroughtheholeontherighthandsideofthe
stove,andslideonewasherontotherod(ifthereisnotsufficient
roomtotherightofthestovetodothisthenremovetheriddler
knob,fitonewasherovertherodandthenslidetherodthroughthe
holefromtheinsideofthestove).
Feedtherodthroughthetwosidefireplatesandslidetheother
washerontotherodsothatthewashersendupoutsidethetwoside
fireplates.Withthesidefireplatespushedtogetherfittheretaining
clipssothatthewasherscomeinsidetheclips.
Slidethesidefireplatesapartsothattheyrestagainstthesidesofthe
firebox.Slotinthefrontandrearsupportplates.
FITTINGTHERIDDLINGGRATE
CongratulationsonbecomingtheownerofaHETASapproved
CharnwoodC-SeriesStove.YourstovehasbeenapprovedbyDEFRA
toburnwoodlogsinasmokecontrolareaifitisusedinaccordance
withtheseinstructions.Itisthereforeveryimportantthatyouread
andunderstandtheseinstructionsbeforeusingthestove.
FUEL
Beforelightingthestovecheckwiththeinstallerthattheworkand
checksdescribedintheInstallationInstructionshavebeencarriedout
correctlyandthatthechimneyhasbeenswept,issoundandfree
fromanyobstructions.Thestoveisnotsuitableforuseinashared
fluesystem.
Rememberthatthestovewillbehotandthatitismadefromhard
materials – ensurethatyouhavegoodbalancebeforeoperatingthe
fire.
Donotuseanaerosolsprayonornearthestovewhenitisalight.
Thereisariskofexplosionorflashignitionofthespray.
Thestoveissuitableforintermittentoperation.
Thisstovehasbeendesignatedtoburnwood.Onlydrywellseasoned
woodshouldbeburntonthisapplianceasburningwetunseasoned
woodwillgiverisetoheavytardepositsinthestove,ontheglassand
withinthechimney.Forthesamereasonhardwoods(suchasAsh,
BeechandOak)arebetterthansoftwoods(suchasPineand
Spruce).Burningwetunseasonedwoodwillalsoresultin
considerablyreducedoutputs.Thewoodshouldbecutandsplitand
thenlefttoseasoninawellventilateddryplaceforatleastoneyear
butpreferablytwoyearsbeforeuse.Approximatesuitablelogsizes
are:
C4&C6 255mm(10in)longand75mm(3in)diameter
C5&C8 305mm(12in)longand75mm(3in)diameter
C7 380mm(15in)longand75mm(3in)diameter.
Thisstoveisnotdesignedtoburnhouseholdwaste.
ForadviceonotherfuelspleasecontactCharnwood.
PETROLEUMCOKEISNOTSUITABLEFORUSEON
THISAPPLIANCE.ITSUSEWILLINVALIDATETHE
GUARANTEE.
Whenusingthestoveinsituationswherechildren,agedand/or
infirmpersonsarepresentafireguardmustbeusedtoprevent
accidentalcontactwiththestove.Thefireguardshouldbe
manufacturedinaccordancewithBS8423:2002.
®
OPERATINGINSTRUCTIONS
4
Fig.1.OptionalGrateKit
FrontGrate
Support
RHSideGrate
Support
GratePlates
RearGrate
Support
Riddler
Rod
Ashpan
LHSideGrate
Support
Fitthegrateplatesintopositionthroughthefrontandreargrate
supportplates,makingsuretheylocatecorrectlyontotheriddler
rod.Fitthefuelretainer.Slidetheashpanunderthegrate.
Oninitiallighting,thestovemaysmokeandgiveoffanodourasthe
siliconpaintwithwhichthefireboxispaintedreactstotheheat.This
isnormalandwillceaseafterashorttime,butmeanwhiletheroom
shouldbekeptwellventilated.
Atfirstonlylightasmallfireandburnitslowlyfortwohourstoallow
anyresidualmoistureinthechimneytoevaporate.
Lightthestoveusingdrykindlingwoodandpaperorfirelighters.Put
thepaper,orfirelighters,andkindlinginthefireboxandcoverwitha
fewsmalldry logs.Opentheaircontrolfully(seeFig.2).Lightthe
paperorfirelighters.Thedoormaybeleftcrackedopenforafew
minutestoassistthecombustionandheatupthefireboxmore
quickly.Whenthekindlingwoodiswellalightaddafewmoresmall
logs,closethedoorbutleavetheaircontrolfullyopen.Whenthe
flamesareestablishedaroundtheselogs,loadthestovewiththe
requiredfuelload.Maintaintheaircontrolatmaximumatthisstage.
Oncethefireisuptotemperaturetheairwashsystemwillbeginto
work,soallowthefiretobecomehotbeforeadjustingtheaircontrol
totherequiredsetting.Duringthelightingperiod,donotleavethe
stoveunattended.Donotleavethedooropenexceptasdirected
abovetoavoidexcessivesmoke.
Whenrelightingthestove,leavetheashonthebaseifburningwood,
unlessitisbecomingtoodeep,inwhichcasesomeofitmaybe
removed.Ifburninghighashcontentfuel,clearthegrateandempty
theashpanbeforerelighting.
LIGHTING
CONTROLLINGTHEFIRE
REFUELLING
ASHCLEARANCE
Therateofburningandhencetheoutputiscontrolledbytheair
control(seeFig.2).
Opentheaircontrolfully(boostposition)whenlightingorwhen
rapidburningisrequired.Itshouldnotbeleftfullyopenforlong
periodsasthiscancauseover-firingorexcessivesmokeproduction.
Forhighoutputmovetheaircontroltothe ‘clickposition’ orforlow
burningtothefullyclosedposition.
Whenthefireisburningnormallytheaircontrolgivesenough
airwashtokeeptheglassclean.However,itwillnotalwaysbe
possibletokeeptheglasscleanwiththeaircontrolfullyclosed.
Keepthefireboxwellfilledbutdonotallowfueltospilloverthetop
ofthefuelretainer.
Logsshouldbeevenlydistributed,fillingthefirebedtogivethemost
pleasingflamepattern.Theaircontrolmustbefullyopenedafter
refuellinguntiltheflamesareestablishedabovethefire.Itisbestto
refuelontoahotbedofash.Ifatthispointthefirestartstodie,the
doormustbecrackedopenuntilthefireisrevived.Ifthefirehas
startedtodiedownbeforerefuelling,thenmorekindlingwoodmust
beadded,theaircontrolopenedfullyandthedoorcrackedopento
re-establishthefirebed addinglargerlogs(seesuitablelog
sizesinFuelsection).Thiswillavoidexcessivesmokeemission.
Careshouldbetaken,especiallywhenburningwood,thatfueldoes
notprojectoverthefuelretainerordamagetotheglassmaybe
causedwhenthedoorisclosed.Itcanalsocausetheglasstoblacken
up.Maximumfillingheightissuchthatlogscannotfallfromthefire
whenthedoorisopened.Insmokecontrolledareasdonotfillthe
stoveabovethelevelofthefrontfirebarsasoverloadingcancause
excesssmoke.Liquidfuelsarenottobeusedonthisappliance.
Theashpanshouldbeemptiedregularlybeforeitbecomestoofull.
Neverallowtheashtoaccumulateintheashpansothatitcomesin
contactwiththeundersideofthegrateasthiswillseriouslydamage
thegrate bars.Theashpanishandledusingthetoolprovided.Care
shouldbetakentoensurethatashiscoolbeforeemptyingitinto
plasticlinersorbins.
before
For
correctfiringwerecommendtheuseofastovepipethermometer
whichmaybepurchasedfromyoursupplierorfromCharnwood.
5
®
OPERATINGINSTRUCTIONS
Fig.2.StoveControls
AirControl
PullouttoOpen
PushintoClose
Door
Handle
Pullto
Open
Low
Output
High
Output
(Click)
Boost
AirControl
positions
IdentificationPlate,
LiftPlatetoView
TomakeashremovaleasierthereisaspecialCharnwoodashcarrier
available.Thismaybepurchasedfromyoursupplieror,incaseof
difficulty,fromCharnwood.
Forreducedburningthefiredoormustbeclosed.
Whenburningwoodinareasthatarenotsmokecontrolled,load
somelargelogsonthefireandallowtoburnforhalfanhourbefore
closingtheaircontrol(thiswillhelptoreducetardepositsinthe
chimney).Someexperimentationmaybenecessarytofindthesetting
mostsuitableforthetypeoffuelbeingusedandthedrawonthe
chimney.
Torevivethefire,emptytheashpan(ifburningfuelotherthan
wood),riddlethefire,andopentheaircontroltomaximum.When
thefireisburningwellloadonmorefuelasnecessaryandadjustthe
aircontroltothedesiredsetting.
REDUCEDBURNING
MAINTENANCE
Cleaning
Cleaning the Glass
When Not in Use
Ifthefireisgoingtobeoutofuseforalongperiod(forinstancein
thesummer)thentopreventcondensation,andhencecorrosion,the
aircontrolshouldbeleftfullyopenandthefiredoorleftajar.ItIs
alsoadvisabletosweepthechimneyandcleanoutthefire.Spraying
theinsideofthedoorandfireboxwithalightoil,suchasWD40,will
alsohelptokeepallinternalpartsworkingwell.
Thestoveisfinishedwithahightemperaturepaintwhichwill
withstandthetemperaturesencounteredinnormaluse.Thismaybe
cleanedwithadamplint-freeclothwhenthestoveiscold.Shouldre-
paintingbecomenecessary,hightemperaturepaintsareavailable
fromyoursupplierorfromstoveshops.
Mostdepositsontheglassmaybeburntoffsimplybyrunningthefire
atafastrateforafewminutes.Ifitbecomesnecessarytocleanthe
glassthenopenthedoorandallowittocool.Cleantheglassusinga
dampclothandthenwipingoverwithadrycloth.Anystubborn
depositsontheglassmayberemovedwithaproprietarystoveglass
cleanerorceramichobcleaner.Donotuseabrasivecleanersorpads
asthesecanscratchthesurfacewhichwillweakentheglassandcause
prematurefailure
Afterlongperiods
wherethefirehasbeenoutofuse,thechimneyandappliance
fluewaysshouldbecleanedbeforelighting.
Door Seals
Servicing
Forthefiretooperatecorrectlyitisimportantthatthedoorseals
areingoodcondition.Checkthattheydonotbecomewornor
frayedandreplacethemwhennecessary.
Itisrecommendedthatthefireisservicedonceayeartokeepitin
firstclassworkingorder.Aftercleaningoutthefireboxthoroughly,
checkthatallinternalpartsareingoodworkingorder,replacingany
partsthatarebeginningtoshowsignsofwear.Checkthatthedoors
sealsareingoodconditionandthatthedoorsealscorrectly.A
servicingguideisavailableonrequest.Repairsormodificationsmay
onlybecarriedoutbytheManufacturerortheirapprovedagents.
UseonlygenuineCharnwoodreplacementparts.
THROATPLATEAND
FLUEWAYCLEANING
CHIMNEYSWEEPING
Itisimportantthatthethroatplateandallthestovefluewaysarekept
cleaninordertopreventpotentiallydangerousfumeemission.They
shouldbecleanedatleastmonthly,andmorefrequentlyifnecessary.
Itisnecessarytoletthefireouttocarryouttheseoperations.
Thefrontofthethroatplateispulledforwardandthenloweredas
showninFig.3.Anysootydepositsshouldthenbesweptfromthe
plateandintothefire.
Returnthethroatplatetoitscorrectposition-raisethefrontofthe
plate,pushitbackandthenloweritontotheretaininglugs.
Wherethechimneypreviouslyservedanopenfire,itispossiblethat
thehigherfluegastemperaturefromastovemayloosensoot
depositswiththeconsequentriskofflueblockage.Itistherefore
recommendedthatthechimneybesweptasecondtimewithina
6
®
OPERATINGINSTRUCTIONS
ThroatPlate
PullUp
andSwingDown
Fig.3.ThroatPlatePosition andLowering
whenre-fuellingthestove.
c)Whenre-fuellingkeepthefuelasfarbackfromthefrontfenceas
possible,donottrytofittoomuchfuelintothefirebox.
d)Donotcompletelyclosetheaircontrol.
Itisalwaysmoredifficulttokeeptheglasscleanwhenrunningthe
stoveveryslowlyforlongperiods.
Ifblackeningoftheglassstilloccurscheckthatallflueconnections
andtheblankingplatearewellsealed.Itisalsoimportantthatthe
chimneydrawissufficientandthatitisnotaffectedbydown-draught.
Whenthechimneyiswarmadraughtreadingofatleast2.5mm
(0.10in.)watergauge(25Pa)shouldbeobtained.Someblackening
oftheglassmayoccurbelowthelevelofthefuelretainer.Thiswill
not obscuretheviewofthefireoraffectitsperformance.
Themostcommoncauseoffumeemissionisfluewayorchimney
blockage.Foryourownsafetythesemustbekeptclean.
Checkthat:
a)Thedooristightlyclosed.
b)Theaircontrolsliderisfullyclosed.
c)Asuitablefuelisbeingused.
d)Doorsealsandairwashslideareintact.
Ifthechimneyisthoroughlyandregularlyswept,chimneyfiresshould
notoccur.However,ifachimneyfiredoesoccurclosetheaircontrol,
FumeEmission
WarningNote:
Properlyinstalledandoperatedthisappliancewillnotemitfumes.
Occasionalfumesfromde-ashingandre-fuellingmayoccur.
Persistentfumeemissionispotentiallydangerousandmustnotbe
tolerated.Iffumeemissiondoespersist,thenthefollowing
immediateactionsshouldbetaken:
a)Opendoorsandwindowstoventilatetheroomandthenleave
thepremises..
b)Letthefireoutandsafelydisposeofthefuelfromthe
appliance.
c)Checkforflueorchimneyblockage,andcleanifrequired.
d)Donotattempttore-lightthefireuntilcauseoffuminghas
beenidentified,ifnecessaryseekprofessionaladvice.
Fireblazingoutofcontrol
ChimneyFires
monthofregularuseafterinstallation.
Thechimneyshouldbesweptatleasttwiceayear.Wherethetop
outletorverticalrearflueconnectorisuseditwillgenerallybe
possibletosweepthechimneythroughtheappliance.
Firstremovethefuelretainerandthethroatplate.Thensweepthe
chimneyensuringthatsootisremovedfromallhorizontalsurfaces
aftersweeping.
Insituationswhereitisnotpossibletosweepthroughtheappliance
theinstallerwillhaveprovidedalternativemeans,suchasasootdoor.
Aftersweepingthechimneytheapplianceflueoutletandthefluepipe
connectingthestovetothechimneymustbecleanedwithaflue
brush.
Afterclearinganysootfromwithinthestove,replacethethroatplate
(seeFig.3)andthefuelretainer.
Checkthat:
a)theairinletisnotobstructedinanyway,
b)chimneysandfluewaysareclear,
c)asuitablefuelisbeingused,
d)thereisanadequateairsupplyintotheroom,
e)anextractorfanisnotfittedinthesameroomasthestove.
f)thereissufficientdrawinthechimney.Oncethechimneyiswarma
draughtreadingofatleast2.5mm(0.10in.)watergauge(25Pa)
shouldbeobtained.
Differencesinchimneydraughtsmeanthatthebestsettingsoftheair
controlswillvaryfordifferentinstallations.Acertainamountof
experimentationmayberequired,howeverthefollowingpoints
shouldbenotedandwithalittlecareshouldenabletheglasstobe
keptcleaninmostsituations:
a)Wetorunseasonedwood,orlogsoverhangingthefrontfencewill
causetheglasstoblacken.
b)Theairwashreliesonasupplyofheatedairtokeeptheglassclean,
therefore,whenlightingthestoveallowthefirebedtobecomewell
establishedbeforeclosingtheaircontrol.Thismayalsobenecessary
FireWillNotBurn
BlackeningofDoorGlass
Differenttypesofsweep’sbrushesareavailabletosuitdifferent
flueways.Forprefabricatedinsulatedchimneysthemanufacturers
instructionswithregardtosweepingshouldbeconsulted.
TROUBLESHOOTING
7
®
OPERATINGINSTRUCTIONS
andtightlyclosethedooroftheappliance.Thisshouldcausethe
chimneyfiretogooutinwhichcasethecontrolsshouldbekept
closeduntilthestovehasgoneout.Thechimneyandfluewaysshould
thenbecleaned.Ifthechimneyfiredoesnotgooutwhentheabove
actionistakenthenthefirebrigadeshouldbecalledimmediately.
Afterachimneyfirethechimneyshouldbecarefullyexaminedfor
anydamage.Expertadviceshouldbesoughtifnecessary.
YourinstallershouldhavefittedaCOalarminthesameroomasthe
appliance.Ifthealarmsoundsunexpectedly,followtheinstructions
givenunder “WarningNoteabove.
IfyouneedfurtherhelpwithyourCharnwoodthenyourInstallerwill
beabletoprovidetheanswerstomostquestions.YourLocal
CharnwoodPremierDealerhasagreatdealofexperienceandwill
alsobeabletoprovidehelpfuladvice.Furtherhelpisavailablefrom
theCharnwoodCustomerServicesdepartmentwhowillbepleased
togiveadvice,ifnecessary.
COALARM
IFYOUNEEDFURTHERHELP
8
®
OPERATINGINSTRUCTIONS
HEALTHANDSAFET YPRECAUTIONS
Pleasetakecarewheninstallingthestovethattherequirementsof
theHealthandSafetyatWorkAct1974aremet.
Sometypesoffirecementarecausticandshouldnotbeallowedto
comeintocontactwiththeskin.Incaseofcontactwashwithplenty
ofwater.
Ifthereisapossibilityofdisturbinganyasbestosinthecourseof
installationthenpleaseuseappropriateprotectiveequipment.
Theremustnotbeanextractorfanfittedinthesameroomasthe
stoveasthiscancausetheappliancetoemitfumesintotheroom.
.
Minimiumareasaregiveninthefollowingtable:
Thisstoveiscapableofintermittentoperation,andisnotsuitablefor
useinasharedfluesystem.
InadditiontotheseinstructionstherequirementsofBS.8303and
BSEN15287-1:2007mustbefulfilled.LocalAuthorityBylawsand
BuildingRegulations,includingthosereferringtonationaland
EuropeanStandards,regardingtheinstallationofSolidFuelburning
appliances,fluesandchimneysmustalsobeobserved.
Buildingregulationsrequirethatwheneveraneworreplacement
fixedsolidfuelorwood/biomassapplianceisinstalledinadwellinga
carbonmonoxidealarmmustbefittedinthesameroomasthe
appliance.Furtherguidanceontheinstallationofthecarbon
monoxidealarmisavailableinBSEN50292:2002andfromthe
alarmmanufacturer'sinstructions.Provisionofanalarmmustnotbe
consideredasubstituteforeitherinstallingtheappliancecorrectlyor
ensuringregularservicingandmaintenanceoftheapplianceand
chimneysystem.
COALARMS
Theremustbeanadequateairsupplyintotheroominwhichthe
applianceisinstalledtoprovidecombustionair.Thecombustionair
supplymustbeviaapermanentlyopenvent.Therequirementfor
minimumfreeareaispartlydependentonthedesignairpermeability
ofthehouse.Inolderpropertiestheairpermeabilitywillbeabove
5.0m /(h.m ),butinsomemodernpropertiesitmaybeless.
3 2
The
ventmustbepositionedsuchthatitisnotliabletoblockage
SPECIFICATION
CHIMNEY
Theoutputsinthetablearebasedona45minutere-fuellingcycle
burningseasonedhardwoodlogs.Alltestsarecarriedoutin
accordancewithBSEN13240.
Inorderfortheappliancetoperformsatisfactorilythechimney
heightmustnotbelessthan4metresmeasuredverticallyfromthe
outletofthestovetothetopofthechimney.Theinternaldimensions
ofthechimneyshouldpreferablybe175mm(7")or200mm(8")
eithersquareorroundandMUSTNOTBELESSTHAN125mm
(5")forC-FourandC-Fiveor150mm(6")forC-Six,C-SevenandC-
Eight.
Ifanexistingchimneyistobeuseditmustbesweptandchecked,it
mustbeingoodcondition,freefromcracksandblockages,and
shouldnothaveanexcessivecrosssectionalarea.Ifitwaspreviously
usedby anopenfirethenthechimneyshouldbesweptonemonth
afterinstallationtoclearanysootfallswhichmayhaveoccurreddue
tothedifferenceincombustionbetweenthestoveandtheopenfire.
Ifyoufindthatthechimneyisinpoorconditionthenexpertadvice
shouldbesoughtregardingthenecessityofhavingthechimneylined.
Ifitisfoundnecessarytolinethechimneythenaliningsuitablefor
SolidFuelmustbeused.
9
®
INSTALLATIONINSTRUCTIONS
Specification
C-Four
C-Five
C-Six
C-Seven
C-Eight
NominalHeat
Output
kW(BTU/hr)
4.9
(16,700)
5.0
(17,000)
6.7
(22,800)
7.6
(25,900)
8.3
(28,300)
StoveWeight
kg
(Packed)
83
96
96
115
119
Flue
Temperature
°C
281
259
272
280
316
FluegasMass
Flowg/s
4.2
5.3
4.3
7.3
6.3
Hearth
Temperature
°C
51.6
69.9
88.1
55.4
53.4
Minimum
distancefrom
combustibles
mm
600side
600rear
500side
400rear
500side
500rear
500side
500rear
600side
650rear
Air
Permeability
m /(h.m )
3 2
MinimumVentArea cm (in )
2 2
C-Five
C-Six
>5.0
No
Requirement
9.4(1.5)
<5.0
27.5(4.3)
36.9(5.7)
Ifthereisnoexistingchimneythenaprefabricatedblockchimneyor
atwinwalledinsulatedstainlesssteelfluetoBSEN15287-1:2007can
beusedeitherinternallyorexternally.Thesechimneysmustbefitted
inaccordancewiththemanufacturersinstructionsandBuilding
Regulations.
Singlewallfluepipeissuitableforconnectingthestovetothe
chimneybutisnotsuitableforusingforthecompletechimney.Ifitis
foundthatthereisexcessivedrawinthechimneythenadraught
stabilisershouldbefitted.
Itisimportantthatthereissufficientdrawinthechimneyandthat
thechimneydoesnotsufferfromdown-draught.Whenthechimney
iswarmthedrawshouldbenotlessthan2.5mm(0.10")watergauge
(25Pa).Ifindoubtaboutthechimneyseekexpertadvice.
HEARTHANDFIRESURROUND
Thestovemuststandonafireproofhearthandmustnotbesituated
closerthantheminimumdistancefromcombustiblematerials(see
specificationtable)tothesidesorrearabovehearthlevelunless
adequatelyfireproofedinaccordancewithlocalbuildingregulations.
Thehearthmustbeoffireproofmaterialandatleast12mm(1/2in.)
thick.Thepositioningofthestoveandthesizeofthehearthare
governedbybuildingregulationsforClass1appliances.These
buildingregulationsstatethatthehearthmustextendinfrontofthe
stovebyatleast300mm(12in.)andtothesidesofthestovebyat
least150mm(6in.).
Ifindoubtastothepositioningofthestove,expertadviceshouldbe
soughteitherfromthesupplierorthelocalbuildinginspector.The
fireplacemustallowgoodcirculationofairaroundtheapplianceto
ensurethatmaximumheatistransferredtotheroomandalsoto
preventthefireplacefromoverheating.Agapof150mm(6")each
sideand300mm(12")abovetheapplianceshouldgivesufficientair
circulation.Ifawoodenmantelpieceorbeamisusedinthefireplaceit
shouldbeaminimumof460mm(18"),andpreferably600mm(24")
fromtheappliance.Insomesituationsitmaybenecessarytoshield
thebeamormantelpiecetoprotectit.
Inorderforthefiretooperatecorrectlyandtoallowforaccess,
theremustbeanairgapbehindtheapplianceofatleast75mm,but
beawarethatthisdistancewillneedtobegreaterinsomecasesto
meetBuildingRegulationrequirements.
Whenthefiredoorisopen,itextendsbeyond
theflatfrontofthestovebythefollowingamounts:
C-Four&C-Six365mm,C-Five436mm,C-Seven515mm,andC-
Eight450mm.
10
®
INSTALLATIONINSTRUCTIONS
RegisterPlate
SootDoor
InSideorRear
OfChimney
RegisterPlate
WithSootDoor
Alternative
SootDoorPositions
Fig.4.VerticalRegisterPlateWithBrickedUpFireplace
RegisterPlate
WithSootDoor
Alternative
SootDoorPositions
Fig.5.HorizontalRegisterPlateWithRearFlueConnection
Fig.6HorizontalRegisterPlateWithTopFlueConnection
CONNECTIONSTOFLUES
Thestovemustbeconnectedtotheflueusingfluepipeofthe
followingsizes:
Iftheoptionalverticalrearflueconnectorisusedthenthechimney
maybesweptthroughtheappliance.
Horizontallengthsoffluemustbekepttoaminimumandshouldnot
bemoreinlengththanthefluediameter.
Thestovecomeswiththeblankingplatefittedtothetopflueoutlet.
Thesealforthe outletisa180mmdiaringofropeseal.Theseal
forthe outletisalengthofadhesivebackedfibrewebbing
suppliedwithinstructions.Thisisappliedtothefluecollarorthe
VerticalRearFlueadapterforrearoutletinstallations.Fortopoutlet
installations,theblankingplatemustberemoved,havethewebbing
fittedto itssealingface,andfittedtotherearflueoutlet.
StoveModelC-Four&C-Five.....................125mm(5")i/dpipe.
StoveModelC-Six,C-Seven&C-Eight........150mm(6")i/dpipe.
top
rear
Thismaybestainlesssteel,castiron,orthickwallsteelpipe.Straight
lengthsofCharnwoodPipetomatchthestoveareavailableif
required.
Thereareseveralwaysofconnectingthestovetotheflue.Theseare
illustratedinFigs.4to7.
Ensurethat
thefoldontheclampingplateisinlinewiththelugsonthefireboxas
showninFig8.Ensurethattheclampingplatedoesnotpreventthe
throatplatefromseatingcorrectly.Allflueconnectionsmustbewell
sealed.
Fortopoutletinstallationsonthe thefluecollar
deflectormustbefittedatthesametimeasthefluecollarbecauseit
usesthesameboltstosecureittothestove.Thelongestlengthofthe
fluecollardeflectormustbealignedwiththefrontofthestoveas
showninFig9.
CFive,Six&Seven
SOOTDOORS
Itispossibletopassa16inchdiametersweepsbrushthroughthe
appliancebutinmostbackoutletinstallationsitwillbenecessaryto
haveasootdoortoenablethechimneytobeswept.Theoptional
verticalrearflueconnectordoesallowthechimneytobeswept
throughthestove.
Sootdoorsmayeitherbeintheactualbrickwork
ofthechimneyorintheregisterplate.Variouspositionsofsoot
doorsareshowninFigs.4to7.
UNPACKINGTHESTOVE
Thestovearrivesboltedandshrink-wrappedtoitspallet.Theremust
beadequatefacilitiesforunloadingandmanoeuvringintoposition
Thewrappingisfirstremoved,thenthestovereleasedfromthepallet
byeitherremovingthesinglebolt(C-4)or4palletbolts(C-5toC-8)
11
®
INSTALLATIONINSTRUCTIONS
RegisterPlate
WithSootDoor
Alternative
SootDoorPositions
Fig.7.HorizontalRegisterPlateWithOptional
VerticalRearFlueConnector
Fig.8.FlueBlankingPlate.
BlankingPlate
Clampingplatefinishes
flushwithinsidefaceof
fireboxtopandbottom.
withGlassFibreWebbing
SealBlankingPlate
GlassFibreWebbing
BlankingPlate
BackofStove
ClampingPlate
M8Nut
FlueCollar
Ropeseal
FlueCollar
Front of Stove
Deflector
Fig.9.FlueCollarDeflectorfitting.
usinga10mmspanner.Thepalletbracketscannowberemovedfrom
thestovebytiltingitandusinga13mmspannertoremovethebolts.
These4boltsarerequiredforlevellingorfixingontheStoreStand.
TheStovemaynowbemovedtoitsfinalposition.Thepalletis
intendedtobecutupandusedforkindlingfuel.
PRELIGHTINGCHECK
COMMISSIONING
Ensurethatthethroatplateisfittedintheroofoftheappliance.The
locationandpositioningofthethroatplateisshowninFig.3.
Checkthatthefrontfenceisfittedcorrectlyandthatthedoorcloses
properly.
Oncompletionoftheinstallationallowasuitableperiodoftimefor
thefirecementandmortartodryoutbeforelightingthefire.Ifno
grateisfittedmakealayerofashorsandonthebaseofthestove
beforelighting.Checktoensurethatsmokeandfumesaretaken
fromtheapplianceupthechimneyandemittedsafely.Alsocheckall
jointsandseals.Oncompletionoftheinstallationandcommissioning
pleaseleavetheoperatinginstructionswiththecustomerandadvise
themontheuseoftheappliance.
UndertheCleanAirActlocalauthoritiesmaydeclarethewholeor
partofthedistrictoftheauthoritytobeasmokecontrolarea.Itisan
offencetoemitsmokefromachimney ofabuilding,fromafurnace
orfromanyfixedboileriflocatedinadesignatedsmokecontrolarea.
Itisalsoanoffencetoacquirean"unauthorisedfuel"forusewithina
smokecontrolareaunlessitisusedinan"exempt"appliance
("exempted"fromthecontrolswhichgenerallyapplyinthesmoke
controlarea).
TheSecretaryofStateforEnvironment,FoodandRuralAffairshas
powersundertheActtoauthorisesmokelessfuelsorexempt
appliancesforuseinsmokecontrolareasinEngland.InScotlandand
WalesthispowerrestswithMinistersinthedevolvedadministrations
forthosecountries.Separatelegislation,theCleanAir(Northern
Ireland)Order1981,appliesinNorthernIreland.Thereforeitisa
requirementthatfuelsburntorobtainedforuseinsmokecontrol
areashavebeen"authorised"inRegulationsandthatappliancesused
toburnsolidfuelinthoseareas(otherthan"authorised"fuels)have
beenexemptedbyanOrdermadeandsignedbytheSecretaryof
CAAANDSMOKECONTROL
TheCleanAirAct1993andSmokeControlAreas
12
®
INSTALLATIONINSTRUCTIONS
StateorMinisterinthedevolvedadministrations.
The
havebeen
recommendedassuitableforuseinsmokecontrolareaswhen
burningwoodlogs.
FurtherinformationontherequirementsoftheCleanAirActcanbe
foundhere:http://smokecontrol.defra.gov.uk/
YourlocalauthorityisresponsibleforimplementingtheCleanAirAct
1993includingdesignationandsupervisionofsmokecontrolareas
andyoucancontactthemfordetailsofCleanAirActrequirements.
CharnwoodC-FOUR, CharnwoodC-SIX,CharnwoodC-FIVE,
CharnwoodC-SEVENandCharnwoodC-EIGHT
13
EN13240:2001
ROOMHEATERSFIREDBYSOLIDFUEL
ADivisionofA.J.Wells&SonsLimitedRegisteredinEnglandNo.03809371
12
BishopsWay,Newport,IsleofWightPO305WS,UnitedKingdom
A.J WELLS & SONS LTDA.J WELLS & SONS LTD
RoomheaterModel
CFour
CFive
CSix
CSeven
CEight
ECCertificateofconformityno:
BR080-CPD-2011
NR080-CPD-2012
CR080-CPD-2012
ER080-CPD-2012
DR080-CPD-2012
Fueltype:
WOODLOGS
WOODLOGS
WOODLOGS
WOODLOGS
WOODLOGS
EmissionofCOincombustion
products:
0.18%
0.19%
0.25%
0.14%
0.15%
Meanfluegastemperature:
281°C
259°C
272°C
280°C
316°C
Spaceheatingthermaloutput:
4.9kW
5.0kW
6.7kW
7.6kW
8.3kW
Energyefficiency
78.3%
75.7%
81.9%
76.9%
78.0%
Minimumdistanceto
combustiblematerials
Side:
Rear:
WithheatshieldandHT+
insulatedflueconnector
(25mminsulation).
Side:
Rear:
600mm
600mm
600mm
200mm
500mm
400mm
500mm
175mm
500mm
500mm
500mm
200mm
500mm
500mm
500mm
240mm
600mm
650mm
550mm
250mm
CSERIES
CECertificateforcompliancewithEN13240:2001andUKHETASrequirements.
®
C-FOUR DIMENSIONS(mm)
14
262
613 560
416
386
84
144
267
373
82
405
114
154
131
45
458
61ID
64OD
763 710
416
386
195
608
OptionalVerticalRearFlueAdapter
StoreStandS
t
andar
dModel
FrontSideRear
PlanView
150150
140i/dtosuit125mm(5")
fluepipe
®
C-FIVE DIMENSIONS(mm)
StoreStandS
t
andar
dModel
FrontSideRear
PlanView
15
455
485
560
611
144
292
398
153
82
130
430
114
76
79
65
458
485
455
745
796
185
292
250
643
OptionalVerticalRearFlueAdapter
140i/dtosuit125mm(5")
fluepipe
®
C-SIX DIMENSIONS(mm)
16
505
63
79
Tosuit80mmducting
161
292
441
615
411
670
119
398
169
131
88
441
146
292
800
855
411
441
185
690
OptionalVerticalRearFlueAdapter
PlanView
FrontSideRear
StoreStandS
t
andar
dModel
156i/dtosuit150mm(6")
fluepipe
®
C-SEVEN DIMENSIONS(mm)
17
800
855
529
185
564
292
690
244
292
160
615
534
564
670
398
169
130
146
440
85
505
59
79OD
76
StoreStandS
t
andar
dModel
FrontSideRear
156i/dtosuit150mm(6")
fluepipe
OptionalVerticalRearFlueAdapter
®
C-EIGHT DIMENSIONS(mm)
OptionalVerticalRearFlueAdapter
500
710
764
465
292
163.0
76
79
61
605
185
470
895
949
500
292
246
790
169
133
146
88
398 443
FrontSideRear
StoreStandS
t
andar
dModel
18
156i/dtosuit150mm(6")
fluepipe
IssueG
19
®
charnwood BISHOPSWAY,NEWPORT,ISLEOFWIGHTPO305WS,UNITEDKINGDOM
T: +4 4 (0) 1983 537799 F:+ 44 (0)19 83 537788 SPARES@CHARNWOOD.COM WW W.CHARNWO OD .COM
®
C-FOUR PARTSLIST
Item PartNo. Description
1# 002/BR001 DoorCasting
2 008/FFW026 1/4HeavyBrassWasher
3 006/PV19 Glass(incseal)
4 008/BR014 HandlepivotPin
5 004/BW23 Glassretainer
6 008/FFS018 M6x16C'sunkSktHdScrew
7 008/PV21 Ropedoorseal
8 004/BR005 Airboxcontrolplate
9 004/BR007 Airinletslide
10# 001/BR010 Firebox
11 004/BR016 Controlrod
12 002/BR017 FuelretainerBR
13 010/BR031 Throatplate
14 010/BR029 RHSideplate
15 010/BR030 InnerBackplate
16 004/BR040 AirboxCover
17 002/DY21 RiddlerKnob
18 008/BR044 GasketBlankingplate
19 008/BR006 GasketAirbox
20 008/FFB034 M8Nylocnut
21 012/BR011 SerialNo.Label
22 002/PV13 DoorLatch
23 008/FFW025 M8WavyWasher
24 008/FFW007 3/8"PlainLightWasher
25 008/FFS050 M8Bolt30mmLong
26 008/AY37 AirControlKnob
27 002/BR034 Woodashretainer
28 008/BR045 AirboxGasket
34 008/FFS025 M6X12BrightPoziPanHd
35 008/BR047 Backgasket
36 008/FFS059 M8x20HexHdBolt
37 008/BR052 Feltwasher
38 011/PV26 SideGasket
39 004/BR053 AirInletSpigotassy
40 004/BR054 Blankingplate
41 004/DY22 RiddlerBlankingDisk
42 010/EY12 Serialnumberhangerbracket
43 010/PV33 VertRearFlueAdaptor
44 002/PV12B Fluecollar
45 012/PV09 Blankingplate
46 002/BR020 Hinge
47 012/BV20 Ashpantool
48 004/BR033 Ashpan
49 002/EY03 GratePlate
50 010/EY04 L.H.GrateSupport
51 010/EY05 R.H.GrateSupport
52 010/EY06 FrontGrateSupport
53 010/BR035 RearGrateSupport
54 010/EY13 RiddlerRodassy
55* 008/PV55 GlassSeal
56* 008/FW29 DoorSealAdhesive
57# 002/BR012 HandleCasting
58 004/BR015 Clickerretainerplate
59 008/ES36~01 BrassBallCatch
60 010/BR022 GrateKit
61* 010/EW51 AshCarrier(OptionalExtra)
62 008/BW39/S HingePinSet
63 008/FFW015 SpringWasher(ThackeryType)
64 008/FFB007 M8x100mmAllenHeadBolt
65 010/BR050/## StoreStand
66* 010/BR057 HeatShield
29 010/BR028 LHSideplate
30 008/BR012 Woodenhandle
31 008/FFS003 PanheadscrewM5X10
32 008/FFS078 Pozipanhead4.2x9.5
33 008/FFB003 CoachBoltM6x20 (OptionalExtra)
Item PartNo. Description
ToobtainsparepartspleasecontactyourlocalstockistgivingModel,PartNo.and
Description.Incaseofdifficultycontactthemanufacturerattheaddressshown.
*Theseitemsarenotshownonthedrawing.
#Pleasespecifycolourwhenordering.
Thisdrawingisforidentificationpurposesonly.
14
15
13
46
12
27
22
5
333145
21
34
19
8
9
16
18
40 25 11
17 26
2837
29
32
39
42
43 44
32
20
24
23
4 7
30
47
1
2
3
6
10 35
58
59
57
38
38
36
62
41
65
6364
67
17
52
50
48
51
53
49
68
60
54
OptionalGrateKit
20
®
C-FIVE PARTSLIST
IssueB
Item PartNo. Description
Item PartNo. Description
(OptionalExtra)
(OptionalExtra)
75* 008/NR039 18mmDoorRopeSeal(V2dooronly)
1# 002/NR001 DoorCasting
2 008/FFW026 M6Heavybrasswasher
3 006/NR019 Glass
4 004/BR014 HandlepivotPin
5 004/BW23 Glassretainer
6 008/FFS018 M6x12Countersunksocketheadscrew
7 008/NR038 DoorSeal
8 004/CR005 Aircontrolplateassembly
9 004/CR007 Airinletslide
10 001/NR010 FireboxAssembly
11 004/ER016 Controlrod
12 002/NR017 Fuelretainer
13 010/NR031 Baffle
14 010/NR029 RHSideplate
17 002/DY21 Riddlerknob
18 008/CR063 Ductgasket
20 008/FFN015 M8PhilidasNut
21 012/NR011 SerialNo.Label
22 002/PV13 DoorLatch
23 008/FFW025 M8Waveywasher
24 008/FFW002 Washer14x6
25 008/FFS050 M8Boltx30mmlong
26 008/AY37 AirControlKnob
27 002/BR034 WoodAshRetainer
28 008/BR045 AirboxGasket
31 008/FFS003 M5x8mmPhilipsPanHd
32 008/FFS025 M6x12PhilipsPanHeadScrew
33 008/FFB003 CoachBoltM6x20
35 004/XV30 Brickbracket
36 008/FFS059 M8x20HexHdBolt
37 008/BR052 Feltwasher
38 008/NR030/S SetofFirebricks
39 008/CR048 FlangedSpigot80mm
40 004/CR064 Ductcoverplate
41 004/DY22 RiddlerholePlug
42 010/EY12 Serialnumberhangerbracket
43 010/PV33 VerticalRearFlueAdapter
44 002/PV12B CastFlueCollar
45 012/PV09 BlankingPlate
46 002/BR020 Hingecasting
47 012/BV20/A Ashpan/DoorOpeningTool
48 004/BR033 Ashpan
49 002/EY03 GratePlate
50 010/NR043 L.H.GrateSupport
51 010/NR042 R.H.GrateSupport
52 010/EY06 FrontGrateSupport
53 010/NR061 RearGrateSupport
54 010/DR060 RiddlerRodassy
55* 008/NR044 GlassSeal
56* 008/FW29 DoorSealAdhesive
57# 002/BR012 Handlearm
58 004/BR015 ClickerRetainerPlate
59 008/ES36 Brassballcatch
60 010/NR022 GrateKit(IncHandle)
61* 010/EW51 AshCarrier
62 008/BW39/S HingePinSet5mmx25mm
63 010/NR070 FlueCollarDeflectorAssy
64 008/DY27 RiddlingTool
65 010/NR050/## Storestand
66 008/FFB007 M8x100AllenHdBolt
67 010/EY51 ClampingPlate
68 008/FFB004 CoachBoltM6x30
69 008/FFN004 M6Nut
70 008/ER036 Washer
71 008/FFS045 M6x16Hexheadedscrew
72 008/FFW015 ThackeryWasher
73 008/FFS078 4.2x9.5PoziPanHeadS/Tscrew
74* 010/NR057 HeatShield
®
charnwood BISHOPSWAY,NEWPORT,ISLEOFWIGHTPO305WS,UNITEDKINGDOM
T: +4 4 (0) 1983 537799 F:+ 44 (0)19 83 537788 SPARES@CHARNWOOD.COM WW W.CHARNWO OD .COM
ToobtainsparepartspleasecontactyourlocalstockistgivingModel,PartNo.and
Description.Incaseofdifficultycontactthemanufacturerattheaddressshown.
*Theseitemsarenotshownonthedrawing.
#Pleasespecifycolourwhenordering.
Thisdrawingisforidentificationpurposesonly.
44 14 6838 707
65
35
31
62
46
6
12
1
27
57
2
3066 472
261169
47
33
1022
9
41
32
43 45 67 6321 42
16
39
8
28
19
20
24
23
58
71
59
29
13 35
18
40
37
49
53
54
64
1751
52
48
50
60
OptionalGrateKit
IssueG
21
®
charnwood BISHOPSWAY,NEWPORT,ISLEOFWIGHTPO305WS,UNITEDKINGDOM
T: +4 4 (0) 1983 537799 F:+ 44 (0)19 83 537788 SPARES@CHARNWOOD.COM WW W.CHARNWO OD .COM
C-SIX PARTSLIST
Item PartNo. Description
68 010/AY51 ClampingPlate
1# 002/BR001 DoorCasting
2 008/FFW026 1/4HeavyBrassWasher
3 006/PV19 Glass(incseal)
4 004/BR014 HandlepivotPin
5 004/BW23 Glassretainer
6 008/FFS018 M6x16C'sunkSktHdScrew
7 008/PV21 Ropedoorseal
8 004/CR005 Airboxcontrolplate
9 004/CR007 Airinletslide
10# 001/CR010 Firebox
11 004/BR016 Controlrod
12 002/BR017 FuelretainerBR
13 010/CR031 Throatplate
14 010/CR029 RHSideplateincgasket
15 010/CR030 InnerBackplate
16 010/CR041 AirboxCover
17 002/DY21 RiddlerKnob
18 008/CR063 DuctGasket
19 008/CR006 AirboxGasket
20 008/FFB034 M8Nylocnut
21 012/CR011 SerialNo.Label
22 002/PV13 DoorLatch
23 008/FFW025 M8WavyWasher
24 008/FFW007 3/8"PlainLightWasher
25 008/FFS050 M8Bolt30mmLong
26 008/AY37 AirControlKnob
27 002/BR034 Woodashretainer
28 008/BR045 AirboxGasket
29 010/CR028 LHSideplate
30 008/BR013 Woodenhandle
31 008/FFS003 M5X10SltdPanScrew
32
33 008/FFB003 CoachBoltM6x20
34 008/FFS025 M6X12BrightPoziPanHd
35 008/CR027 Backgasket
36 008/FFS059 M8x20HexHdBolt
37 008/BR052 Feltwasher
38 008/CR026 SideGasket
39 008/CRO48 AirInletSpigotassy
40 004/CR064 Blankingplate
41 004/DY22 RiddlerBlankingDisk
42 010/EY12 Serialnumberhangerbracket
43 010/TW33 VertRearFlueAdaptor
44 002/CH12B Fluecollar
45 012/TW09 Blankingplate
46 002/BR020 Hinge
47 012/BV20/A Ashpantool
48 004/BR033 Ashpan
49 002/EY03 GratePlate
50 010/CR043 L.H.GrateSupport
51 010/CR042 R.H.GrateSupport
52 010/CR065 FrontGrateSupport
53 010/CR061 RearGrateSupport
54 010/CR013 RiddlerRodassy
55* 008/PV55 GlassSeal
56* 008/FW29 DoorSealAdhesive
57# 002/BR012 HandleCasting
58 004/BR015 Clickerretainerplate
59 008/ES36/01 Brassballcatch
60 010/CR022 GrateKit(inchandle)
61* 010/EW51 AshCarrier(OptionalExtra)
62 008/BW39/S HingePinSet
63 010/CR070 FlueCollarDeflector
64 008/DY27 RiddlingTool
65 010/CR050/## StoreStand
66 008/FFB007 M8x100AllenHd.Bolt
67* 010/CR057 HeatShield(OptionalExtra)
008/FFS078 Pozipanhead4.2x9.5
Item PartNo. Description
ToobtainsparepartspleasecontactyourlocalstockistgivingModel,PartNo.and
Description.Incaseofdifficultycontactthemanufacturerattheaddressshown.
*Theseitemsarenotshownonthedrawing.
#Pleasespecifycolourwhenordering.
Thisdrawingisforidentificationpurposesonly.
®
49
60
48
50
51
54
17
52
53
64
OptionalGrateKit
14
13
15
29
62
46
6
9
62
2
3
30
66
27
12
1
3
5
8
7
44
43
45
68
21
34
42
47
22
19
8
16
18 40 36
57
28
10
26
38
35
4
2532
39
18
32
63
65
DETAILA
9
11
58
20242359
37
41
IssueA
22
®
C-SEVEN PARTSLIST
Item PartNumber Description
1# 002/ER001 DoorCasting
2 008/FFW026 M6Heavybrasswasher
3 006/ER019 Glass
4 004/BR014 HandlepivotPin
5 004/BW23 Glassretainer
6 008/FFS018 M6x12Countersunksocketheadscrew
7 008/ER003 DoorSeal
8 004/CR005 Aircontrolplateassembly
9 004/ER007 Airinletslide
10 001/ER010 FireboxAssembly
11 004/ER016 Controlrod
12 002/ER017 Fuelretainer
13 010/ER031 Baffle
14 010/ER029 RHSideplate
17 002/DY21 Riddlerknob
18 008/CR063 Ductgasket
19 008/CR006 AirboxGasket(upper)
20 008/FFN015 M8PhilidasNut
21 012/ER011 SerialNo.Label
22 002/PV13 DoorLatch
23 008/FFW025 M8Waveywasher
24 008/FFW002 Washer14x6
25 008/FFS050 M8Boltx30mmlong
26 008/AY37 AirControlKnob
27 002/ER034 WoodAshRetainer
28 008/BR045 AirboxGasket
29 010/ER028 LHSideplate
30 008/BR013 Woodenhandle
31 008/FFS003 M5x8mmPhilipsPanHd
32 008/FFS025 M6x12PhilipsPanHeadScrew
33 008/FFB003 CoachBoltM6x20
35 004/XV30 Brickbracket
36 008/FFS059 M8x20HexHdBolt
37 008/BR052 Feltwasher
38 008/ER030/S SetofFirebricks
39 008/CR048 FlangedSpigot80mm
40 004/CR064 Ductcoverplate
41 004/DY22 RiddlerholePlug
42 010/EY12 Serialnumberhangerbracket
43 010/TW33 VerticalRearFlueAdapter
44 002/CH12B CastFlueCollar
45 012/TW09 BlankingPlate
46 002/BR020 Hingecasting
47 012/BV20/A Ashpan/DoorOpeningTool
48 004/ER033 Ashpan
49 002/EY03 GratePlate
50 010/ER043 L.H.GrateSupport
51 010/ER042 R.H.GrateSupport
52 010/ER065 FrontGrateSupport
53 010/ER061 RearGrateSupport
54 010/ER060 RiddlerRodassy
55* 008/ER044 GlassSeal
56* 008/FW29 DoorSealAdhesive
57# 002/BR012 Handlearm
58 004/BR015 ClickerRetainerPlate
59 008/ES36 Brassballcatch
60 010/ER022 GrateKit(IncHandle)
61* 010/BW51 AshCarrier(OptionalExtra)
62 008/BW39/S HingePinSet5mmx25mm
63 010/CR070 FlueCollarDeflectorAssy
64 008/DY27 RiddlingTool
65 010/ER050/## Storestand
66 008/FFB007 M8x100AllenHdBolt
67 010/AY51 ClampingPlate
68 008/FFB004 CoachBoltM6x30
69 008/FFN004 M6Nut
70 008/ER036 Washer
71 008/FFS045 M6x16Hexheadedscrew
72 008/FFW015 ThackeryWasher
73 008/FFS078 4.2x9.5mmPozipanheadselftappingscrew
74* 010/ER057 HeatShield(OptionalExtra)
Item PartNo. Description
®
charnwood BISHOPSWAY,NEWPORT,ISLEOFWIGHTPO305WS,UNITEDKINGDOM
T: +4 4 (0) 1983 537799 F:+ 44 (0)19 83 537788 SPARES@CHARNWOOD.COM WW W.CHARNWO OD .COM
49
17
54
51
48
52
53
50
64
OptionalGrateKit
60
40 2518
16
33
29
32
21 42 4368
70 44
45
67
10
7
1413
38
62
6
38
38
46
12
5
3
1
30
66
57
41
36
33
19
8
28
9
71
69 11
26
24
23
59
58
38
20
63
47
27
2
4
22
31
35
3739
65
ToobtainsparepartspleasecontactyourlocalstockistgivingModel,PartNo.and
Description.Incaseofdifficultycontactthemanufacturerattheaddressshown.
*Theseitemsarenotshownonthedrawing.
#Pleasespecifycolourwhenordering.
Thisdrawingisforidentificationpurposesonly.
IssueA
®
charnwood BISHOPSWAY,NEWPORT,ISLEOFWIGHTPO305WS,UNITEDKINGDOM
T: +4 4 (0) 1983 537799 F:+ 44 (0)19 83 537788 SPARES@CHARNWOOD.COM WW W.CHARNWO OD .COM
®
C-EIGHT PARTSLIST
Item PartNo. Description
1# 002/DR001 DoorCasting
2 008/FFW026 1/4HeavyBrassWasher
3 006/DR019 Glass(incseal)
4 004/BR014 HandlepivotPin
5 004/KV23 Glassretainer
6 008/FFS018 M6x16C'sunkSktHdScrew
7 008/DR091 Ropedoorseal
8 004/CR005 Airboxcontrolplate
9 004/DR007 Airinletslide
10# 001/DR010 Firebox
11 004/BR016 Controlrod
12 002/BR017 FuelretainerBR
13 010/DR031 Throatplate
14 010/DR029 RHSideplateincgasket
15 010/DR030 InnerBackplate
16 004/CR040 AirboxCover
17 002/DY21 RiddlerKnob
18 008/CR063 BlankingPlateGasket
19 008/CR006 AirboxGasket
20 008/FFN015 M8Philidasnut(Lockingnut)
21 012/DR011 SerialNo.Label
22 002/PV13 DoorLatch
23 008/FFW025 M8WavyWasher
24 008/FFW007 3/8"PlainLightWasher
25 008/FFS050 M8Bolt30mmLong
26 008/AY37 AirControlKnob
27 002/BR034 Woodashretainer
28 008/BR045 AirboxGasket
29 010/DR028 LHSideplate
30 008/BR013 Woodenhandle
31 008/FFS003 M5X10SltdPanScrew
32 008/FFS025 PhillipsheadscrewM6X12
33 008/FFB003 CoachBoltM6x20
34 008/FFS025 M6X12BrightPoziPanHd
35 008/DR047 Backgasket
36 008/FFS059 M8x20HexHdBolt
37 008/BR052 Feltwasher
38 011/DR038 SideGasket
39 004/CR048 AirInletSpigotassy
40 004/CR064 Blankingplate
41 004/DY22 RiddlerBlankingDisk
42 010/EY12 Serialnumberhangerbracket
43 010/TW33 VertRearFlueAdaptor
44 002/PV12B Fluecollar
45 012/TW09 Blankingplate
46 002/BR020 Hinge
47 012/BV20/A Ashpantool
48 004/BR033 Ashpan
49 002/EY03 GratePlate
50 010/DR043 L.H.GrateSupport
51 010/DR042 R.H.GrateSupport
52 010/CR065 FrontGrateSupport
53 010/DR061 RearGrateSupport
54 010/DR060 RiddlerRodassy
55* 008/DR091 GlassSeal
56* 008/FW29 DoorSealAdhesive
57# 002/BR012 HandleCasting
58 004/BR015 Clickerretainerplate
59 008/ES36/01 Brassballcatch
60 010/DR022 GrateKit(inchandle)
61* 010/EW51 AshCarrier(OptionalExtra)
62 008/BW39/S HingePinSet
63 008/FFW015 SpringWasher(Thackerytype)
64 008/FFB007 M8x100mmAllenHeadBolt
65 010/BR050/## StoreStand
66* 010/DR057 HeatShield
67 010/AV51 ClampingPlate
68 008/DY27 RiddlingTool
Item PartNo. Description
(OptionalExtra)
23
ToobtainsparepartspleasecontactyourlocalstockistgivingModel,PartNo.and
Description.Incaseofdifficultycontactthemanufacturerattheaddressshown.
*Theseitemsarenotshownonthedrawing.
#Pleasespecifycolourwhenordering.
Thisdrawingisforidentificationpurposesonly.
27
12
57
30
6
1
62
46
6
62
14
13
15
45
67
21
34
42
38
3538
41
7
26
11
9
28
8
19
25
36
25
37
18
40
16
10
5
3
43
43
2
20
39
47
4
65
66
22
23 24
2931
32
33
55
58 59 6364
49
53
54
52
17
51
48
50
68
60
OptionalGrateKit
A Division of A .J.W ells & Sons Limit ed R egis t er ed in England N o. 038093 7 1
charnwood BISHOPSWAY,NEWPORT,ISLEOFWIGHTPO305WS,UNITEDKINGDOM
T : + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 C O N TA C T U S A T W W W . C H A R N W O O D . C O M
y o u rp r e m i e rd e a l e r
REV.C-Seriesv30
4.13
®
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Charnwood C Six bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Charnwood C Six in de taal/talen: Engels als bijlage per email.

De handleiding is 1,81 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Charnwood C Six

Charnwood C Six Gebruiksaanwijzing - Nederlands - 23 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info