Install Multi-Function Door
Control Panel
(Model 5000E Only)
Remove about 6mm of insulation from both ends of 2-
strand bell wire. Connect one end to terminal screws
on back of multi-function door control panel as
follows: white/red to terminal screw 1 and white to
terminal screw 2.
Locate the Door Control within sight of the door at a
minimum height of 3.5m where small children cannot
reach, and away from all moving parts of the door and
door hardware. Fasten the Multi-Function Door
Control Panel securely with 6ABx1" screws. If
installing into drywall, drill 4mm holes and use the
anchors provided.
Run the bell wire up the wall and across the ceiling to
the opener. Use insulated staples to secure the wire in
several places. Be careful not to pierce the wire with a
staple, thereby resulting in a short.
Receiver terminals and the antenna are located on the
back panel of the opener. Position the antenna wire as
shown.
Then connect the bell wire as follows: white/red to
terminal screw 1 and white to terminal screw 2.
Remember to affix the User Safety Instruction label
to the wall near the Door Control, and the
Maintenance Instruction label in a prominent
location on the inside of the garage door.
If the label adhesive will not adhere to your garage wall
surface (or becomes loose with time) use tacks to secure
the label alongside the control button.
OPERATION OF THE
MULTI-FUNCION DOOR CONTROL PANEL
THE DOOR CONTROL PUSH BAR:
Press to open or close the door. Press again to
REVERSE the door during the closing cycle or to
STOP the door while it's opening.
LIGHT FEATURE: Press the Light button. If the
opener light is off, it will turn on.
If the opener light is on, (even in the 4-1/2 minute
automatic cycle) it will turn off.
But if you use the Light Button to turn the light(s) on
and then activate the opener, the light(s) will turn off
after 4-1/2 minutes.
The Light Feature will not turn the opener light(s) off
when the door is in motion.
LOCK FEATURE: Designed to prevent operation of
the door from portable remote controls. However, the
door will open and close from the Door Control push
bar and from the Keylock and the Keyless Entry
Accessories.
TO ACTIVATE: Press and hold the Lock button for 2
seconds. The push bar light will flash as long as the
Lock feature is on.
TO TURN OFF: Press and hold the Lock button again
for 2 seconds. The push bar light will stop flashing.
Normal operation will resume. The Lock feature will
also turn off whenever the "Smart" button on the
opener end panel is activated.
INSTALL THE LIGHT(S): Install a 75 watt maximum
light bulb in each socket. Light will turn ON and remain
lit for 4-1/2 minutes when power is connected. After
4-1/2 minutes, they will turn OFF.
If bulb burns out prematurely due to vibration,
replace with bulb specifically packaged for garage
door openers.
INSTALL LENS (Models 5000E & 4000E): Side lens
into guides as shown. Snap bottom tabs into lens slots.
For convenience, lenses may be installed after
adjustment Step 3 on Page 22.
Staples
2-Strand Bell Wire
Door Control
Push Bar
L
IG
H
T
L
O
C
K
RED
1
Multi-Function
Door Control Panel
WHITE
2
Light
Button
Lock
Button
Multi-Function
Door Control Panel
Terminal Screws
2-Strand
Bell Wire
Opener
Terminal
Screws
Antenna
Back Panel of Opener
KG
KG
M.D.C. CERT. NO.
1
3
9
7
5
132C2105-1
WARNING: To reduce the risk of severe injury
or death by entrapment, when adjusting either
the force or limits of travel controls ensure that
the door reverses on a 1 inch object (or a 2 x 4
board laid flat). See instructions for proper
adjustment procedure.
This device complies
with FCC Rules Part
15. Operation of this
device is subject to the
following conditions:
1. This device may
not cause harmful
interference. 2. This
device must accept
any interference
that may be received,
including interference
that may cause
undesired operation.
PART NO: Nº DE PIÈCE:
D.O.C. CERT. NO.
DATE:
Sears Roebuck & Co.
Sears Canada Inc., Toronto
Assembled in Mexico - Assemblé du Mexique
PAT. #RE29,525; 4,750,201; 4,806,930 Other Patents Pending.
AVERTISSEMENT: Pour réduire les risques de
blessures mortelles par happement, après tout
réglage de la force de déclenchement ou des
seuils de fin de course s'assurer que le sens de
la course s'inverse lorsque la porte entre en
contact avec un object de 13 mm (1 po) de
hauteur (ou un madrier de 2 x 4 de section, à
plat) posé sur le sol. Effectuer les reglages
selon les procédures décrites dans la notice.
1
3
9
7
5
2 3
TO PROGRAM RECEIVER CODE
FOR EACH REMOTE CONTROL
1. Press and HOLD remote control
transmitter push button.
2. Press receiver code button. The opener
light will flash once.
3. Release transmnitter button. Opener
has learned code.
TO ERASE ALL RECEIVER CODES
1. Press and HOLD receiver code button.
Green indicator light alongside will turn
ON.
2. When light turns OFF (about 6
seconds) ALL codes are erased from
opener memory.
1
Lens
Guide
Lens
Tab
Lens
Slot
75 Watt Max.
Light Bulb
(Model 5000E Only)
Lens
WIRING INSTRUCTIONS FOR ACCESSORIES
The Protector System
To opener terminal screws:
White to 2 and White/Black to 3
Outside Keylock:
To opener terminal screws:
White/Red to 1 and White to 2
15

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Chamberlain-4000E

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Chamberlain 4000E bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Chamberlain 4000E in de taal/talen: Engels als bijlage per email.

De handleiding is 0,89 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info