580479
26
Verklein
Vergroot
Pagina terug
1/31
Pagina verder
26
While your telescope requires little maintenance, there are a few things to remember that will ensure your telescope performs
at its best.
C
C
a
a
r
r
e
e
a
a
n
n
d
d
C
C
l
l
e
e
a
a
n
n
i
i
n
n
g
g
o
o
f
f
t
t
h
h
e
e
O
O
p
p
t
t
i
i
c
c
s
s
Occasionally, dust and/or moisture may build up on the objective lens or primary mirror depending on which type of
telescope you have. Special care should be taken when cleaning any instrument so as not to damage the optics.
If dust has built up on the optics, remove it with a brush (made of camel’s hair) or a can of pressurized air. Spray at an angle to
the glass surface for approximately two to four seconds. Then, use an optical cleaning solution and white tissue paper to remove
any remaining debris. Apply the solution to the tissue and then apply the tissue paper to the optics. Low pressure strokes should
go from the center of the lens (or mirror) to the outer portion.
Do NOT rub in circles!
You can use a commercially made lens cleaner or mix your own. A good cleaning solution is isopropyl alcohol mixed with
distilled water. The solution should be 60% isopropyl alcohol and 40% distilled water. Or, liquid dish soap diluted with
water (a couple of drops per one quart of water) can be used.
Occasionally, you may experience dew build-up on the optics of your telescope during an observing session. If you want to
continue observing, the dew must be removed, either with a hair dryer (on low setting) or by pointing the telescope at the
ground until the dew has evaporated.
If moisture condenses on the inside of the optics, remove the accessories from the telescope. Place the telescope in a dust-
free environment and point it down. This will remove the moisture from the telescope tube.
To minimize the need to clean your telescope, replace all lens covers once you have finished using it. Since the cells are
NOT sealed, the covers should be placed over the openings when not in use. This will prevent contaminants from entering
the optical tube.
Internal adjustments and cleaning should be done only by the Celestron repair department. If your telescope is in need of
internal cleaning, please call the factory for a return authorization number and price quote.
C
C
o
o
l
l
l
l
i
i
m
m
a
a
t
t
i
i
o
o
n
n
o
o
f
f
a
a
N
N
e
e
w
w
t
t
o
o
n
n
i
i
a
a
n
n
The optical performance of most Newtonian reflecting telescopes can be optimized by re-collimating (aligning) the
telescope's optics, as needed. To collimate the telescope simply means to bring its optical elements into balance. Poor
collimation will result in optical aberrations and distortions.
Before collimating your telescope, take time to familiarize yourself with all its components. The primary mirror is the
large mirror at the back end of the telescope tube. This mirror is adjusted by loosening and tightening the three
screws, placed 120 degrees apart, at the end of the telescope tube. The secondary mirror (the small, elliptical mirror
under the focuser, in the front of the tube) also has three adjustment screws; you will need optional tools (described
below) to perform collimation. To determine if your telescope needs collimation first point your telescope toward a
bright wall or blue sky outside.
Aligning the Secondary Mirror
The following describes the procedure for daytime collimation of your telescope using the optional Newtonian Collimation
Tool (#94183) offered by Celestron. To collimate the telescope without the Collimation Tool, read the following section on
night time star collimation. For very precise collimation, the optional Collimation Eyepiece 1 ¼” (# 94182) is offered.
If you have an eyepiece in the focuser, remove it. Rack the focuser tube in completely, using the focusing knobs, until its
silver tube is no longer visible. You will be looking through the focuser at a reflection of the secondary mirror, projected
from the primary mirror. During this step, ignore the silhouetted reflection from the primary mirror. Insert the collimating
cap into the focuser and look through it. With the focus pulled in all the way, you should be able to see the entire primary
mirror reflected in the secondary mirror. If the primary mirror is not centered in the secondary mirror, adjust the secondary
mirror screws by alternately tightening and loosening them until the periphery of the primary mirror is centered in your view.
DO NOT loosen or tighten the center screw in the secondary mirror support, because it maintains proper mirror position.
26

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Celestron AstroMaster 70 EQ bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Celestron AstroMaster 70 EQ in de taal/talen: Engels als bijlage per email.

De handleiding is 11,47 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Celestron AstroMaster 70 EQ

Celestron AstroMaster 70 EQ Gebruiksaanwijzing - Deutsch - 31 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info