471843
15
Verklein
Vergroot
Pagina terug
1/28
Pagina verder
CC-TR100
2726
CC-TR100
Lap
No.
LAP
Lap time
Average lap speed
Split time
Trip lap distance
MODE-
1
+
MODE-
2
Lap
No.
Split time
Average lap speed
Average lap
heart rate
Average lap
cadence
Lap calorie
consumption
Lap time
Average lap speed
21
LAP
LAP
Alternating data display
Record and store data
Data storage function
Data storage allows you to create data files that are downloadable to your personal computer,
allowing for analysis of recorded training data. Data recorded includes speed, heart rate, ca-
dence, trip distance, and elapsed time. The data is recorded in time intervals (memory timing)
selected by the user.
When Data Storage is on, the
icon will be on (the default setting is on). Recorded data is
stored in a data file as soon as initial set-up has been performed and data is being measured.
Lap data, HR and Cadence data recorded during data storage are all recorded on a data file.
Up to 99 files can be stored within the memory capacity of the TR100. These files can be
downloaded to a personal computer using the download kit (optional accessory).
Without the download kit
The default setting of data storage in "on". However, in order to download to a personal
computer requires the optional download kit. If you do not wish to download data to your
personal computer, be sure to turn the Data Storage setting off on the menu screen to avoid
unnecessary memory consumption (see page 41).
With the download kit:
Follow the steps below for data storage.
Up to 99 data files can be stored until the remaining memory is 0%.
When the remaining memory is at 0% while data is being recorded, the icon will
flash, alerting full memory. Delete old data files to use more memory.
Before recording and storing data, select an appropriate recording interval for sufficient
memory space.
Set the data recording interval for data storage
View and delete files when finished to manage remaining memory
View stored data
Download to personal computer
See Data storage on page 41.
See Data file on page 39.
See PC Link on page 42.
See Checking data file on page 39.
MODE-
2
MODE-
1
Lap function
Recording lap data
Pressing the Lap button on the main display while riding records lap data. Immedi-
ately after recording, the lap number is displayed, alternating between "lap time" /
"average lap speed" and "split time" / "lap distance".
NOTE: Up to 199 laps can be recorded.
Lap times cannot be shorter than 5 seconds; pressing the LAP button
consecutively within 5 seconds will not result in a new lap. New laps can
not be recorded when viewing recorded lap data.
The lap function does not record lap intervals longer than 100 hours or
9999.99 (six 9s) km.
NOTE: Viewing lap data depends on the on/off status of "data storage."
When "data storage" is on:
The recorded lap data can be viewed on the main unit display, and is also
saved in a data file. It disappears from the display when the main (or all) data
is reset, but it is stored in the data file and can be transferred to a personal
computer. Lap data will remain in the computer as long as the data file is not
deleted. To obtain more free space for laps, data files will need to be deleted
(see "Data file" on page 39).
When "data storage" is off:
The recorded lap data can be viewed on the main unit display. It is deleted as
soon as the main measurement data or all measurement data is reset. The
data cannot be transferred to a personal computer.
Reading lap data
Press the MODE-1 and MODE-2 buttons simultaneously to view recordad lap data.
The lap recall screen displayes the most recent laps first. Use MODE-1 or MODE-2
buttons to cycle through the laps. Pressing MODE-1 and MODE-2 simultaneously
will exit from the lap recall screen.
NOTE: The lap recall screen will not appear if there is no lap data recorded.
The recorded lap data is deleted when the main measurement data or all
measurement data is reset.
Leaving the lap viewing screen idle for one minute will return automati-
cally to the measuring screen.
Changing lap numbers
Measuring Screen
Recording lap date
Alternating data display
(5 Sec.)
Measuring Screen
Recording lap date
Lap time
Split time
START
Lap time and split time
The lap time indicates the time elapsed between two consecutive pressings of the
LAP button.
The split time indicates the total elapsed time from the start of the exercise.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Cateye CC-TR100 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Cateye CC-TR100 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,89 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info