I f once the appliance is installed there is access to
the lower part, a protection panel (wooden or some-
thing similar) ought to be placed at the distance indi-
cated in the figure.
Electrical connection
Prior to carrying out the electrical connection, please
ensure that:
the plant charac- teristics are such as to follow what
is indicated on the matrix plate placed at the bottom
of the working area;
- that the plant is fitted with an efficient earth
connection, following the standards and law
provisions in force.
- The earth connection is compulsory in terms of
the law.
Should there be no cable and/or plug on the equip-
ment, use suitable absorption material for the wor-
king temperature as well, as indicated on the matrix
plate. Under no circumstance must the cable reach
a temperature above 50°C of the ambient tempera-
ture.
Insert in the fixed wiring a mean for disconnection
from the supply mains having a contact separation in
all poles that provide full disconnection under over-
voltage category III conditions, in accordance with
the wiring rules. The plug or omnipolar switch must
be easily reached on the installed equipment.
This appliance is not intended to be used via an ex-
ternal timer or a remote control system.
The manufacturers decline any responsibility in the
event of non-compliance with what is described
above and the accident prevention norms not being
respected and followed.
To avoid all risk, if the power cable becomes dama-
ged, it must only be replaced by the manufacturer,
by an authorised service centre, or by a qualified
electrician.