Operation Guide 3147
6
To view altitude records and the current Altimeter Mode stopwatch
session record
Altitude records Current stopwatch session record
REC
(
20
)
REC
(
2
)
REC
(
1
)
MAX
MIN
ASC
DSC
MAX
MIN
ASC
DSC
Historical record
E
E
E
BB
B
E
E
EE
BBB
B
E
E
EE
BBB
B
C
C
C
1. Enter the Data Recall Mode.
2. Use the C button to cycle between the altitude records, current Altimeter
Mode stopwatch record, and the historical record.
3. When the record you want is displayed, use the E (+) button and B ()
button to scroll through the data. Holding down the E or B button scrolls
data at high speed.
4. After you are finished viewing data, press D to exit the Data Recall Mode.
Dashes (
xxxx) will be displayed if data has been deleted or if there is no
corresponding data due to error, etc. In such cases, total ascent (
ASC)
and total descent (
DSC) values will show zero.
When total ascent (
ASC) or total descent (DSC) exceeds 99,995 meters
(or 99,980 feet), the applicable value will restart from zero.
Clearing the Historical Record
Use the following procedure to clear the contents of the historical record and
restart all values from zero.
To clear the historical record
1. Press the D button to enter the Data Recall
Mode.
2. Hold down A.
CLR will appear in the upper part of the
display.
3. Keep A held down for an additional two
seconds until
CLR starts flashing.
The historical record high altitude screen will
reappear when data deletion is complete.
If you release the A button part way through
the above procedure, the watch will return to
the historical record high altitude screen
without deleting the data.
Barometer/Thermometer
This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.
You can calibrate the pressure sensor and the temperature sensor if you
suspect that readings are incorrect.
To take barometric pressure and temperature readings
In the Timekeeping Mode, press the D button to
enter the Barometer/Thermometer Mode. This
will start barometric pressure and temperature
measurements automatically.
It can take up to four or five seconds for the
barometric pressure reading to appear after
you enter the Barometer/Thermometer Mode.
Barometric pressure is displayed in units of
1hPa (or 0.05 inHg).
l
l
l
l
l
l
l
l
l
Temperature
Barometric
pressure
Barometric
pressure
graph
The displayed barometric pressure value changes to
xxxx
hPa (or inHg) if
a measured barometric pressure falls outside the range of 260 hPa to
1100 hPa (7.65 inHg to 32.45 inHg). The barometric pressure value will
reappear as soon as the measured barometric pressure is within the
allowable range.
Temperature is displayed in units of 0.1°C (or 0.2°F).
The displayed temperature value changes to
xxx
°C (or °F) if a measured
temperature falls outside the range of 10.0°C to 60.0°C (14.0°F to
140.0°F). The temperature value will reappear as soon as the measured
temperature is within the allowable range.
In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.
You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius (°C) or Fahrenheit
(°F) as the display unit for the measured temperature value. See To select
the temperature, barometric pressure, and altitude units.
See Barometer and Thermometer Precautions for important precautions.
Barometric Pressure Graph
Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure change indicator readings.
The barometric pressure graph shows readings of previous measurements for
up to 24 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.
A rising graph generally means improving weather.
A falling graph generally means deteriorating weather.
Note that if there are sudden changes in weather or
temperature, the graph line of past measurements may run
off the top or bottom of the display. The entire graph will
become visible once barometric conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.
Barometric reading that is out of range (260 hPa/mb to 1,100 hPa/mb or
7.65 inHg to 32.45 inHg)
Sensor malfunction
Not visible on
the display.
Barometric Pressure Change Indicator
l
l
l
l
l
l
l
l
l
A
A
Barometric pressure graph
Barometric pressure
change indicator
In the Barometer/Thermometer Mode, press the A button to toggle between
the barometric pressure graph and the barometric pressure change indicator.
This indicator (
) indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.
Pressure differential is indicated in the range of ±4 hPa, in 1-hPa units.
The barometric pressure change indicator (
) is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).
Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential also can be read in inHg units as
shown in the illustration.
or
More than +4hPa
+3hPa
+2hPa
+1hPa
±0hPa
1hPa
2hPa
3hPa
Less than 4hPa
Barometric pressure
change indicator
About Barometric and Temperature Measurements
Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, barometric pressure and temperature measurements are taken every
five seconds.
During barometric pressure measurements, the watch may not be able to
update its timekeeping display contents normally. Correct timekeeping is
maintained internally, however.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Casio 3147 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Casio 3147 in de taal/talen: Engels als bijlage per email.

De handleiding is 5,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Casio 3147

Casio 3147 Gebruiksaanwijzing - Nederlands - 12 pagina's

Casio 3147 Gebruiksaanwijzing - Deutsch - 13 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info