Important!
If you want to perform both bidirectional and northerly calibration, be sure
to perform bidirectional calibration first, and then perform northerly
calibration. This is necessary because bidirectional calibration cancels any
previously set northerly calibration setting.
The more correctly you perform bidirectional calibration, the better the
accuracy of the bearing sensor readouts. You should perform bidirectional
calibration whenever you change environments where you use the bearing
sensor, and whenever you feel that the bearing sensor is producing
incorrect readings.
Precautions about bidirectional calibration
You can use any two opposing directions for bidirectional calibration. You
must, however, make sure that they are 180 degrees opposite each other.
Remember that if you perform the procedure incorrectly, you will get wrong
bearing sensor readings.
Make sure that you do not move the watch while calibration of either
direction is in progress.
You should perform bidirectional calibration in an environment that is the
same as that where you plan to be taking direction readings. If you plan to
take direction readings in an open field, for example, calibrate in an open
field.
To perform bidirectional calibration
1. Press A to enter the Digital Compass Mode.
2. Hold down E until
x1x appears on the
display, which indicates the setting screen.
At this time, the magnetic north pointer
flashes at the 12 oclock position to indicate
that the watch is ready to calibrate the first
direction.
3. Place the watch on a level surface facing any direction you want, and
press A to calibrate the first direction.
xxx is shown on the display while calibration is being performed.
When calibration of is successful, the display will show
OK and x2x,
and the magnetic north pointer flashes at the 6 oclock position. This
means that the watch is ready for calibration of the second direction.
4. Rotate the watch 180 degrees.
5. Press A again to calibrate the second direction.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
xxx is shown on the display while calibration is being performed. When
calibration is successful, the display will show
OK and the Digital Compass
Mode (showing the angle value) screen.
If
xxx appears and then changes to
ERR
(error) on the calibration
screen, it means that there is something wrong with the sensor. When
ERR
disappears after about one second, try performing the calibration
again. If
ERR
keeps appearing, contact your original dealer or nearest
authorized CASIO distributor to have the watch checked.
To perform northerly calibration
1. While in the Digital Compass Mode, hold
down E until
x1x appears on the display,
which indicates the setting screen.
2. Press D to start the northerly calibration
procedure.
At this time,
-N- (north) appears on the
display.
l
l
l
l
l
l
l
l
l
3. Place the watch on a level surface, and position it so that its 12 oclock
position points north (as measured with another compass).
4. Press A to start the calibration operation.
--- is shown on the display while calibration is being performed. When
calibration is successful, the display will show
OK and the Digital Compass
Mode (with
0
° shown as the angle value).
If
--- appears and then changes to
ERR
(error) on the calibration
screen, it means that there is something wrong with the sensor. When
ERR
disappears after about one second, try performing the calibration
again. If
ERR
keeps appearing, contact your original dealer or nearest
authorized CASIO distributor to have the watch checked.
Barometer and Thermometer Precautions
The pressure sensor built into this watch measures changes in air
pressure, which you can then apply to your own weather predictions. It is
not intended for use as a precision instrument in official weather prediction
or reporting applications.
Sudden temperature changes can affect pressure sensor readings.
Temperature measurements are affected by your body temperature (while
you are wearing the watch), direct sunlight, and moisture. To achieve a
more accurate temperature measurement, remove the watch from your
wrist, place it in a well ventilated location out of direct sunlight, and wipe all
moisture from the case. It takes approximately 20 to 30 minutes for the
case of the watch to reach the actual surrounding temperature.
Pressure Sensor and Temperature Sensor Calibration
The pressure sensor and temperature sensor built into the watch are
calibrated at the factory and normally require no further adjustment. If you
notice serious errors in the temperature readings produced by the watch, you
can calibrate the sensor to correct the errors.
Important!
Incorrectly calibrating the barometric pressure sensor can result in incorrect
readings. Before performing the calibration procedure, compare the
readings produced by the watch with those of another reliable and accurate
barometer.
Incorrectly calibrating the temperature sensor can result in incorrect
readings. Carefully read the following before doing anything.
Compare the readings produced by the watch with those of another reliable
and accurate thermometer.
If adjustment is required, remove the watch from your wrist and wait for 20
or 30 minutes to give the temperature of the watch time to stabilize.
To calibrate the pressure sensor and the temperature sensor
1. Press B to enter the Barometer/
Thermometer Mode.
2. Hold down E until
SET appears in the
upper display area.
3. Release E, and wait for four or five more
seconds until either
OFF or the current
reference temperature value (if set) start to
flash. This is the setting screen.
If you want to calibrate the barometric
pressure sensor, press D to move the
flashing to the middle display area. This is
the pressure sensor calibration screen.
At this time,
OFF or the barometric
pressure value should be flashing on the
display.
4. Use the C (+) and A () buttons to set the
calibration value in the units shown below.
Temperature 0.1
°
C (0.2
°
F)
Barometric Pressure 1 hPa (0.05inHg)
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Pressing A and C at the same time returns to the factory calibration
(
OFF).
5. Press E to return to the Barometer/Thermometer Mode screen.
To select the temperature, barometric pressure, and altitude units
1. Enter the Timekeeping Mode.
2. Hold down E until the city code starts to
flash, which indicates the setting screen.
3. Use D to select the setting screen for the unit
you want to change.
See step 2 under To set the time and date
for information about how to scroll through
setting screens.
4. Press C to change the unit setting.
Each press of C changes the selected unit
setting as shown below.
Temperature
°
C and
°
F
Barometric Pressure hPa and inHg
Altitude m and ft
5. After the settings are the way you want, press E to exit the setting screen.
l
l
l
l
l
l
l
l
l
l
l
l
l
Calibrating the Bearing Sensor
Whenever you suspect that direction readings produced by the watch are
wrong, you should calibrate it. You can use either one of two calibration
procedures:
bidirectional calibration
or
northerly calibration
.
Use bidirectional calibration when you want to take readings within an area
exposed to magnetic force. This type of calibration should be used if the
watch becomes magnetized for any reason.
With northerly calibration, you teach the watch which way is north (which
you have to determine with another compass or some other means). You
could use this calibration procedure, for example, to set the watch to indicate
true north instead of magnetic north.
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Casio 2894 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Casio 2894 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,97 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Casio 2894

Casio 2894 Gebruiksaanwijzing - Nederlands - 13 pagina's

Casio 2894 Gebruiksaanwijzing - Deutsch - 13 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info