Directions for use of ACCESS COOLER English
3
Congratulations !
Congratulations with your new Access Cooler, which is one of the
most advanced impulse coolers in the market. In order to make
sure that you will get the utmost benefit of the cooler, we
recommend that you read this operation direction carefully before
putting the cooler to use.
Should you afterwards have questions, then please contact your
agent, who will be able to guide you.
Unpacking
Immediately upon receipt of the cooler you should make sure that
the cooler has no damage in connection to the transportation.
Transportation damages must be complained to the forwarder
within 24 after receipt of the cooler. The cooler has to be
transported in a vertical position and should also be unpacked in
an upright position.
Putting to use
The cooler is to be levelled onto a flat-face foundation. The cooler
is to be placed in dry environments with an ambient temperature of
max. +30°C and a relative air humidity of not more than 55%.
Avoid placing directly close to heat sources and also not in direct
sunlight. Make sure that there is free and unimpeded circulation of
air around the cooler, but the cooler must still not be exposed to
directly draught.
Prior to use the interior of the cooler should be cleaned with tepid
water. You are not allowed to use detergent soaps, scouring
powder or solvents.
The cooler is to be connected to the correct mains voltage. This
can be seen from the rating place, which is placed inside the
cooled compartment of the cooler. Do not connect the cooler until
the cooler seems to have reached the ambient temperature of the
room. Please be aware of the fact that it takes 2 hours before the
cooler is cold and ready to be loaded with goods.
Using
The cooler is designed for exposure and impulse buying of pre-
cooled soft drinks in the retail trade. The cooler is dimensioned as
a conservator and as such it is less appropriated for chilling. Make
sure that the goods in the cooler are placed in a way that the
necessary air-condition in the cooler is not prevented.
Do never stack the goods higher than the fan grill at the back of
the cooler!!!
Make sure that the airflow in the front part of the cooler is free of
goods and/or foreign bodies.
The cooler may be used for run exposure.
Extra protection
Your freezer or refrigerator, for commercial or private use, requires
extra protection for your safety. If your premises have earthed
electrical installations, the wall sockets will have facilities for a
three-pole plug. Make sure that the green/yellow-coloured wire is
connected to the earthing pin.
If your installation is not earthed you must install a ground fault
circuit interrupter switch. Otherwise ask your local certified
electrician how to establish this extra protection.
Warning concerning upright coolers / chest freezers
containing flammable refrigerants:
Keep the cabinet’s vent holes free and ensure free ventilation
around the whole cabinet.
Do not try to accelerate defrosting by means of scraper,
screwdriver, hair dryer or the like.
The refrigeration unit must not be damaged.
Do not use electrical appliances in the refrigerated
compartment or in the compressor Compartment.
Mode of action
The air is circulated internally in the cooler by a vent. In this way
the air is directed through an evaporator in which the air is cooled.
The air humidity contained by the air is placed onto the evaporator
in the shape of ice. This ice must be removed on a regular basis,
when the control of the cooler stops the cooling but at the same
time allows the internal air circulation to continue. As such the air
in the cooler is used to increase the temperature of the evaporator
above freezing level and as such melts the ice, which has settled
onto the evaporator. The melted ice is led from there to the
compressor compartment, where the water is re-evaporating –
however, now outside the cooler.
When the control detects that the evaporator is cleaned from ice
the cooling will restart automatically.
Operation
If your cooler is supplied by a light canopy it will be switched on/off
by a switch, which is placed in the gable of the light canopy. The
temperature of the cooler should be adjusted in the control placed
at the bottom at the backside of the cooler. There you can also
read the temperature of the cooler. Printing the arrow key up or
down respectively in order to increase or slow-down can change
the temperature the temperature respectively. When you have set
the requested temperature you should print shortly on the button
marked “SET”.
Defrosting frequency is set from the side of the factory and should
not be changed.
Service
The condenser, which is placed behind the air inlet at the lower
end of the cooler, must be cleaned on a regular basis, depending
of the dust in the room where the cooler is placed. However, this
must be done once every third month.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Caravell 104-115 Access Cooler bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Caravell 104-115 Access Cooler in de taal/talen: Engels als bijlage per email.

De handleiding is 0,07 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info