764904
21
Verklein
Vergroot
Pagina terug
1/32
Pagina verder
Owners Manual
Spa operation - ML551Control Pad (UK/Europe/North America)
START UP
When your spa is first powered up, it will go into Priming mode, indicat-
ed by “Pr.The Priming mode will last for less than 5 minutes (press
“Warm” button to skip Priming Mode) and then the spa will begin to heat
and maintain the water temperature in the Standard mode.
TEMPERATURE ADJUSTMENT
Temp (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100F°/37°C. The last measured
temperature is constantly displayed on the LCD.
Note: that the last measured spa temperature displayed is current
only when the pump has been running for at least 2 minutes.
Press the “Warm2” or “Cool” button to display and adjust the set
temperature. After 3 seconds, the LCD will automatically display the last
measured spa temperature.
JETS 1
Touch the “Jets 1” button once to activate the low speed of the pump and
again for the high speed. Press the “Jets 1” button again to turn off the
pump. If left running, the low speed of the pump will automatically turn off
after 4 hours, and the high speed will automatically turn off after 15
minutes. It may also activate for at least 2 minutes every 30 minutes
to detect the spa temperature and then to heat to the set temperature
if needed, depending upon mode. When the low speed turns on auto-
matically in its Filtration cycle, it cannot be deactivated from the panel;
however, the high speed may be started.
Note: Filtration Cycles will activate every 12 hours from the time spa was
first powered up.
Note: Circulation pumps may also be installed into some makes of spas,
which will run the heater and filtration cycles. The circulation pump cannot
be controlled on the topside panel and will run for duration of heating or
Filtration cycles.
JETS 2
Touch the “Jets 2” button once to activate and again to turn off. If left
running the Pump will automatically turn off after 15 minutes.
Note: Jets 2 will purge for 5 minutes at the beginning of each filter cycle.
JETS 3
Touch the “Jets 3” button once to activate pump 3, and press again to
turn off. If left running jets 3 will automatically turn off after 15 minutes.
Note: Jets 3 will purge for 5 minutes at the beginning of each filter cycle.
BLOWER/JETS 4
Touch the “Blower/Jets 4” button once to activate pump 3, and press
again to turn off. If left running Blower/Jets 3 will automatically turn off
after 15 minutes.
Note: Jets 4 will purge for 5 minutes at the beginning of each filter cycle.
LIGHT
Press the “Light” button to turn the light on and off. If left on, the light
automatically turns off after 4 hours.
To change the light effect sequence: Press the light button on then
off, then immediately press the button again (within 5 seconds) to
allow you to select another lighting effect (i.e flashing, intermittent,
fading) repeat sequence until desired lighting effect is achieved.
MODE
This button is used to switch between Standard, Economy or Sleep Mode
settings.
Standard Mode (“Std”) is programmed to maintain the desired
temperature. Note that the last measured spa temperature displayed is
current only when the pump has been running for at least 2 minutes.
“Std” will be displayed momentarily when you switch into Standard
Mode. (Spa will restart heating when 0.5 degree temperature is lost in
spa)
Economy Mode (“Ecn”) heats the spa to the set temperature only
during filter cycles. “Ecn” will alternate with temperature when
heater current, “Ecn” will display solid when heater is not current. (Spa
will only heat within Filter cycle sessions)
Sleep Mode (“SLP”)heats the spa to within 20°F/10°C of the set
temperature only during filter cycles.
“SLP” will alternate with temperature when heater current, “SLP” will
display solid when heater is not current. (Spa will only heat within Filter
cycle sessions)
To switch between Modes. Press “Mode” button, then “Cool” button until
you reach desired mode, then press “Mode” button to select.
PRESET FILTER CYCLES
The first Filter Cycle begins 6 minutes after the spa is powered up. The
second Filter Cycle begins 12 hours later.
Filter duration is programmable from 1 to 12 hours. Indicated by ‘F 1’, ‘F
2’, ‘F 3’ until ‘F 12’
- The default Filter time is ‘F 2.
- To program, press “Warm” button, then “Jet 1.
- Press the “Cool” button to adjust to desired setting.
- To select and continue press “Jet 1” button. “DN”, “D” or “N” will
now be shown on display.
“DN” = Day and Night Filtration
“D” = Day Filtration
“N” = Night Filtration
(Please note: 2 Filtration cycles daily is recommended)
- To Select Program press “Cool” until desired setting.
- To select and Exit press “Jet 1” button
Freeze Protection - ICE
If the temperature sensors detect a drop to approximately 44 °F (6.7 °C)
within the heater, then the pump(s) and blower will automatically activate
to provide freeze protection.
The equipment will stay on until 4 minutes after the sensors detect that
the spa temperature has risen to approx. 45°F (7.2 °C) or higher.
N.B. In colder climates, an optional additional freeze sensor may be added
to protect against freeze conditions that may not be sensed by the
standard sensors. Aux freeze sensor protection acts similarly except
with the temperature thresholds determined by the switch and without a
4-minute delay in turn off. See your dealer for details.
ML551 (8 Button) GL2KM3 St Lawrence 13 & 16’ Swim Spa (UK/Europe)
ML551 (8 Button) EL2000 St Lawrence 13 & 16’ Swim Spa (North America)
Molex type
ML/GL Connector
20
21

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Canadian Spa Company Winnipeg 2016 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Canadian Spa Company Winnipeg 2016 in de taal/talen: Engels als bijlage per email.

De handleiding is 3,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info