802432
6
Verklein
Vergroot
Pagina terug
1/132
Pagina verder
6
C. Temperature / timer down button
Press an air oscillation button (H), after the device turns on, automatic air oscillation function turns on, the louver will swing continuously
the left and the right; by pressing the button again the movement will stop and the louver remain in that position.
Dehumidifying mode –
The radius of horizontal air oscillation is 30 degrees left and 30 degrees right direction from the middle vertical.
- When the device is working, press button “G”, the LCD screen flashes, press the button “C” or “D” to set up the quantity of hours need to
pass before the device will shut off automatically. The LCD screen stops flashing, the timer icon will be illuminated, LCD screen shows
required to achieve temperature. This is a delayed start function.
REMOTE CONTROLLER operation – picture E
The water full indicator lamp “N” will be illuminated and the buzzer will alarm for several second, then the compressor will stop to work when
the inner device water tank will be full.
- Press button “K” to select dehumidifying mode, the LCD screen will show “dh”. Under dehumidifying mode, sleep mode cannot be setup,
and fan speed is fixed on slow fan speed automatically and cannot be changed. In order to switch off the dehumidifying mode select other
operation mode: cooling or fan mode. 13The function of drain plug ( ) is to drain the condensate water from the device's upper part. Its use
is determined according to the local air humidity. It is need to open the drain plug ( ) and pour out the condensate water if the device 13
operates when local air humidity is high or the device operates on dehumidification mode continuously for 12-24 hours continuously. In dry
cooling mode (low air humidity) it is not necessary to open the drain plug ( ) because there is no need to drain the condensate.13
- Press button “J” to select cooling mode, next press the button “L” to get slow fan speed button or press the button “M” to get fast fan
speed button. Next press button “ C” or “ D” to adjust required temperature from 16 to 31, buttons are not available in fan or
dehumidifying mode.
Timer set up -
Timer operation range can be fixed by each one hour from 1 to 24 hours.
- When the device is not working, press button “G”, the LCD screen flashes, press the button “C” or “D” to set up the quantity of hours after
the device will start to operate. The LCD screen stops flashing and timer icon will be illuminated.
Water full -
- The sleep mode is automatically programmed. After the first hour of operation, the temperature will increase by 1 , after the second hour
of operation, the temperature will increase by another 1 , and then remain at the same level.
Cooling mode -
Fan mode -
- Press button “E” again to cancel sleep mode.
Sleep mode –
- Next press button “ C” or “ D” to adjust required temperature from 16 to 31.
- At first Press button “J” to cooling mode, next press button “E” to turn on the sleep mode, then the device will work on Energy-Saving and
quiet type.
NOTE: Sleep mode is not available in dehumidify and fan modes.
- Press button “F” to select fan mode, the LCD screen will show “FA”, next press the button “L” to get slow fan speed button or press the
button “M” to get fast fan speed button. During fan mode operation the temperature and sleeping functions cannot be setup.
Automatic air oscillation function –
Press button “A” to turn on and turn off the device, the buzzer will play signal once.
MODE SELECTION on manual operation of control panel –
G. Timer button
When the device is power on, choose mode you need between cooling mode or fan mode or dehumidifying mode as below:
CONTROL PANEL manual operation – picture D
E. Sleep mode button
F. Fan speed selection button
D. Temperature / timer up button
H. Air oscillation button
When the is powered on for the first time, the buzzer will shout, and then the device will get into standby status.
Button "B" - press it to select operation mode: cool mode → dry mode → fan mode.
Button "A" - the device will be started when it is energized or will be stopped, if you press this button again.
The remote controller transmits signals to the system.
Button "C" / "D" - press to set up the operation time from 1 to 24 hours or required room temperature from 15 to 31°C when cooling mode is
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Camry CR 7929 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Camry CR 7929 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds als bijlage per email.

De handleiding is 5.92 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info