6.2 - PowerBox™ Comfort 24l Additional cleaning
notice
You can remove the textile liner as shown drawing H1.
Never put in the washing machine.
First clean outside and inside with damp cloth. Please ensure
that you correctly place the liner back under the plastic box
in order to keep original performance.We advise you to use
a ruler to put the liner back.( Drawing H2)
7.TROUBLESHOOTING GUIDE
The PowerBox™ thermo-electric cooler is guaranteed for 2
years. If you have a problem with your thermo-electric cooler,
we advise you to read the following with care.
7.1 - Pr
oblem with connection
Your cooler and the outside fan are not running
(Green LED off).
• Check the car lighter socket. In most vehicles, the ignition
must be turned on for the lighter to work. If the ignition is
turned on but the cooler is not operating. Remove the plug
from the socket immediately, and make the following checks:
- Cigarette lighter socket: when the cigarette lighter is used
frequently, it can be soiled by tobacco, causing a bad elec-
tric contact. Clean it with a non-metallic brush.
- If the cooler plug heats abnormally in the cigarette lighter,
clean the socket or check to make sure the plug is assem-
bled correctly.
- Connector fuse: the connector of your 12Vdc power
supply cable is protected by a fuse (7A). Check that the
fuse has not blown by unscrewing the cooler 12Vdc
connector plug. (drawing I)
7.2 - Pr
oblem with cooling
• The green LED is working, but the cooler does not cool
correctly and the outside fan is not running.The fan motor
is probably defective, contact After Sales Service.
• The cooler does not cool correctly and the outside fan is
running. Open the lid to check the operation of the inside fan:
- If the inside fan is not running, the fan motor is probably
defective, Contact After Sales Service.
- If the inside fan is running, the Peltier System is probably
defective, Contact After Sales Service.
8. GUARANTEE (drawing J)
The PowerBox™ thermo-electric cooler is guaranteed
for 2 years. Our general guarantee conditions cover
the cooler. For repair, return the unit to the point of purchase
or to the After Sales Service, with the following information:
1. A copy of the receipt - with the date of purchase.
2.The reason for the claim / A description of the fault
concerned.
This does not affect your statutory rights.
Please only return the Thermo-electric lid.
TECHNICAL CHARACTERISTICS
PowerBox™ PowerBox™
24l Classic-A 28l Classic -A
ref. 068679 ref. 069180
Capacity 24l 28l
Voltage 12Vdc 12Vdc
Intensity 4.5A 4.5A
Power Input 54W 54W
Weight 3.5
kg
3.8
kg
Heating Capacity
Battery Control
Insulation without
CFC and HCFC
●●
Lid insulation EPS foam EPS foam
Box insulation PU foam PU foam
Refrigerating Unit:
thermo-electric system
●●
Extra Passive lid
Dimensions (cm) (drawing K)
A 34.5 34.5
B2222
C3238
D 27.5 27.5
E 38.5 38.5
F 42.5 50
PowerBox™ PowerBox™ PowerBox™
28l Classic-AP 24l Comfort-A 28l Deluxe-B
ref. 069182 ref. 068678 ref. 069181
Capacity 28l 24l 28l
Voltage 12Vdc 12Vdc 12Vdc
Intensity 4.5A 4.5A 4.5A
Power Input 54W 54W 54W
Weight 4.3
kg
3.3
kg
4.3
kg
Heating Capacity 65°C
Battery Control ●
Insulation without
CFC and HCFC
●●●
Lid insulation EPS foam EPS foam EPS foam
Box insulation PU EPE closed PU
foam cells foam foam
Refrigerating Unit:
thermo-electric system
●●●
Extra Passive lid ●●
Dimensions (cm) (drawing K)
A 34.5 34.5 34.5
B222222
C383238
D 27.5 27.5 27.5
E 38.5 38.5 38.5
F 50 42.5 50
United Kingdom, Ireland • Consumer Service • Coleman
®
Uk Plc
Gordano Gate Portishead • BRISTOL BS20 7GG • ENGLAND
Phone: 0044 1275 845 024 - Fax: 0044 1275 849 255
E-mail: customerservices@colemanuk.co.uk
GB
5