E  UTILISATION
OPERATING PRECAUTIONS:
DO NOT install the appliance next to a wall, curtains or a
sofa or armchair.
DO NOT cover the appliance with clothes or other objects.
DO NOT move the appliance when in operation.
The appliance must ALWAYS be directed to the centre of
the room.
The appliance must be put in a dry place.
This appliance protecting grid is designed to prevent
fire hazards or burns and no part shall be permanently
removed.
THE GRID DOES NOT TOTALLY PROTECT YOUNG CHILDREN
OR THE DISABLED.
E - 1 - Igniting the appliance:
Note: Gas opening and closing controls are located on gas
bottle and/or on pressure reducing valve.
Ignition spark and gas inlet control are actuated from the
control panel located in the appliance top right section. (fig. 1
item 1) and (fig. 5 items A and B)
1. Open bottle cock and/or pressure reducing valve handle and
carry out a leak test.
2. Press control button (A) for 10 seconds to allow the gas to
reach the safety pilot burner (fig. 1 and 6 item 2).
3. Push the flame ignition button (B) next to the (
) symbol
all the way down several times while holding down the
control button (A) for 10 seconds. The thermocouple is
activated and the safety valve does not cut off gas feed.
Release control button (A)
4. Check whether the appliance did light up. If not, repeat the
procedure from step 2.
Note: Some air may be trapped in the gas line. This will prevent
the appliance from lighting up during the first attempt. In this
case, it is necessary to repeat the ignition procedure several
times until the safety pilot burner lights up.
During appliance operation, the safety pilot burner must
remain permanently lit in order to ensure correct operation of
the atmosphere analyser.
During the first setting to service, operate the appliance at
maximum power for at least 15 minutes in order to eliminate
the typical new appliance smell due to the presence of
protecting substances applied to the component parts.
Ventilate the room during this operation.
E - 2 - SHUTTING DOWN THE APPLIANCE:
- Close bottle cock and/or gas pressure reducing valve handle.
THIS APPLIANCE IS EQUIPPED WITH AN ATMOSPHERE
ANALYSER DEVICE WHICH AUTOMATICALLY TURNS OFF
THE APPLIANCE SHOULD THE ROOM CONTAIN TOO HIGH A
CARBON DIOXIDE PERCENTAGE (Co2).
IN THIS CASE, THOROUGHLY VENTILATE THE ROOM,
OTHERWISE THE APPLIANCE WILL NOT RELIGHT.
F  REMOVING OR REPLACING THE GAS BOTTLE
- Check that gas bottle cock and/or pressure reducing valve
handle is in the closed position.
- Open appliance rear plate (fig. 4 item B) and remove the
bottle from its housing, taking care not to pull or bend the
hose.
- Disconnect pressure reducing valve from gas bottle.
- Install the new gas bottle and carry out a leak test as
described under paragraphs D-1 and D-2.
- Check tightness in compliance with indications of paragraph
D-2).
D  CONNECTING THE GAS BOTTLE
If an empty bottle is in place, read paragraph F- “Removing or
replacing gas bottle”.
To install or remove a gas bottle, always operate in a well-
ventilated place and never in presence of a flame, spark or heat
source (cigarette, electric appliance, etc.).
- Open appliance rear plate (fig. 1 item 3).
Note: if the appliance is new, remove the plastic cable tie
(Figure 1 number 4), lift and remove rear plate (3).
D - 1- Installing gas bottle:
- Position the gas bottle on the floor behind the appliance.
- Check whether bottle cock and/or pressure reducing valve
handle is in “closed” position.
- Screw in or engage pressure reducing valve to gas bottle or
gas bottle cock (fig. 3 item B).
- Install gas bottle through appliance rear so that the
hose does not touch appliance metal panels and is not
excessively bent or pinched.
- Check that the hose runs normally and is neither bent nor
pulled.
- Install appliance rear plate (fig. 4 item A).
D - 2 - Tightness:
In case of leak, appliance gas supply must be shut down
using gas bottle cock and/or pressure reducing valve
handle.
Do not carry out leak tests with a flame, use a gas leak
detecting liquid.
- Apply gas leak detecting liquid to bottle/pressure reducing
valve/hose/appliance unions.
- Open the gas inlet (bottle cock and/or pressure reducing
valve handle) (fig. 4).
- If bubbles appear, this means that there are gas leaks.
- To remove the leak, tighten hose nuts and/or hose clamps
if any. If a part is defective, have it replaced. The appliance
should not be returned to service until the leak is removed.
- Close gas bottle cock.
Important:
In case of gas leak or odour, immediately close bottle cock
and/or pressure reducing valve handle. Enhance room
ventilation by opening the windows. Ask a specialised
technician to check the appliance and proper bottle
connection.
A leak test should be carried out at least once a year and
whenever the gas bottle is changed.
GB
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Campingaz IR 3000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Campingaz IR 3000 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 1,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info