662398
9
Verklein
Vergroot
Pagina terug
1/71
Pagina verder
9
E - UTILISATION
OPERATING PRECAUTIONS
DO NOT install the appliance next to a wall,
curtains or a sofa or armchair.
DO NOT cover the appliance with clothes or other
objects.
DO NOT move the appliance when in operation.
The appliance must ALWAYS be directed to the
centre of the room.
The appliance must be put in a dry place.
This appliance protecting grid is designed to
prevent fire hazards or burns and no part shall be
permanently removed.
THE GRID DOES NOT TOTALLY PROTECT YOUNG
CHILDREN OR THE DISABLED.
E - 1 - Igniting the appliance
Note: Gas opening and closing controls are located on
gas bottle and/or on pressure reducing valve.
Ignition spark, gas inlet control and temperature or
power controls are actuated from the control panel
located in the appliance top right section (fig. 1 item 1)
and (fig. 5 items A, B and C).
1- Open bottle cock and/or pressure reducing valve
handle and carry out a leak test.
2-a-CR 5000 Version and CR 5000 Turbo Versions
Electrically connect the CR 5000 Turbo Version.
Caution: The appliance was designed to be supplied
with a 230 V 50 Hz voltage. Your installation must be
equipped with a grounding connection compliant
with electrical systems specifications in force.
- Do not place the heater just below an electric socket.
- Do not use the heater near a bath, shower or
swimming pool.
Set handle (A) to position (START) and press the
handle for 10 seconds to allow the gas to reach the
pilot burner (fig. 5).
2-b-CR 5000 Thermo Version
Set handle (C) to the maximum position (IIII) and
press control button (A) for 10 seconds to allow the
gas to reach the pilot burner (fig. 5).
3- Fully press several times the LH button marked with
a stylised lightning (
) (B) for lighting up the
flame, while holding handle (A) or control button (A)
depressed for 10 seconds. The thermocouple is
activated and the safety valve does not cut off gas
feed.
Release button A or handle A.
4- Check whether the appliance did light up. If not,
repeat the procedure from step 2).
5- The appliance must be held in maximum position for
about 10 minutes in order to fully activate the catalytic
panel.
Note: Some air may be trapped in the gas line. This
will prevent the appliance from lighting up during the
first attempt. In this case, it is necessary to repeat the
ignition procedure several times until the safety pilot
burner lights up.
During appliance operation, the safety pilot burner
must remain permanently lit in order to ensure correct
operation of the atmosphere analyser.
During the first setting to service, operate the appliance
at maximum power for at least 15 minutes in order
to eliminate the typical new appliance smell due to
the presence of protecting substances applied to the
component parts.
Ventilate the room during this operation.
national regulations in force (BS, UNI, UNE, etc....).
The hose shall be 0.50 m long. It shall be replaced if
it appears to be damaged or cracked. Do not pull or
twist the hose. Keep it away from parts that are likely
to get heated.
- Check tightness in compliance with indications of
paragraph D-2.
D - CONNECTING THE GAS BOTTLE
If an empty bottle is in place, read paragraph
F-”Removing or replacing gas bottle”.
To install or remove a gas bottle, always operate
in a well-ventilated place and never in presence of
a flame, spark or heat source (cigarette, electric
appliance, etc.).
- Open appliance rear plate (fig. 1 item 3).
Note: If the appliance is new, remove the plastic cable
tie (Figure 1 number 4), lift and remove rear plate (3).
D - 1 - Installing gas bottle:
- Position the gas bottle on the floor behind the appliance.
- Check whether bottle cock and/or pressure reducing
valve handle is in “closed” position.
- Screw in or engage pressure reducing valve to gas
bottle or gas bottle cock (fig. 3 item B).
- Install gas bottle through appliance rear so that the
hose does not touch appliance metal panels and is
not excessively bent or pinched.
- Check that the hose runs normally and is neither bent
nor pulled.
- Install appliance rear plate (fig. 4 item A).
D - 2 - Tightness:
In case of leak, appliance gas supply must be
shut down using gas bottle cock and/or pressure
reducing valve handle.
Do not carry out leak tests with a flame, use a gas
leak detecting liquid.
- Apply gas leak detecting liquid to bottle/pressure
reducing valve/hose/appliance unions.
- Open the gas inlet (bottle cock and/or pressure
reducing valve handle) (fig. 4).
- If bubbles appear, this means that there are gas
leaks.
- To remove the leak, tighten hose nuts and/or hose
clamps if any. If a part is defective, have it replaced.
The appliance should not be returned to service until
the leak is removed.
- Close gas bottle cock.
Important:
In case of gas leak or odour, immediately close
bottle cock and/or pressure reducing valve handle.
Enhance room ventilation by opening the windows.
Ask a specialised technician to check the appliance
and proper bottle connection.
A leak test should be carried out at least once a year
and whenever the gas bottle is changed.
GB
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Campingaz CR 5000 Thermo bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Campingaz CR 5000 Thermo in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 1,74 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info