BRULA NEO operating instructions
2. Safety instructions
• At the start of combustion, the BRULA NEO must be activated by
pressing the screen so that the throttle valve opens. A fire may only
be ignited if the throttle valve (air slider) is at 100
• The BRULA NEO combustion control may only be used in combination
with a wood-fired fireplace.
• Only fireplaces which are ordered with this combustion control system
and that are appropriately prepared from the factory can be combined
with the BRULA NEO.
• The combustion control system cannot be retrofitted!
• The maximum ambient temperature for the electrical components is
50°C. Measures must be taken by the customer to ensure that this
temperature is not exceeded.
• The total electrical installation of the individual components may only be
conducted by an authorised specialist company.
• All electrical installations are to be carried out as per the VDE regulations
(e.g. VDE 0105, VDE 0116, VDE 0100, etc.) and the technical connection
conditions of the local power company.
• All equipment must be switched off at the main switch before performing
work on it.
• The cables must be laid so as to allow maintenance work to be performed
and the individual components of the BRULA NEO to be replaced without
any problems.
• Building moisture and condensation are to be avoided as these can result
in corrosion and failure of the electrical components.
• The connecting cable of the flue gas temperature sensor can only be
extended with a special compensation cable!
• The specified factory settings which are required for the safe operation of
the combustion control may not be changed.
• The installed wires on the fireplace insert must not be pulled. Outside the
fireplace insert, these must be installed so that no tensile forces and no
compression, chafing or shearing points are created.