771276
13
Verklein
Vergroot
Pagina terug
1/20
Pagina verder
13
next setting.
3. Repeat step 2 for setting hours, minutes, seconds, year, month, date,
hour offset, language and daylight saving time (DST).
NOTE!
1. The unit will automatically exit setting mode if no button was pressed
in 60 seconds.
2. The hour offset is for DCF and MSF version. Its range is between -23
and +23 hours.
3. The language options are English (EN), French (FR), German (DE),
Spanish (ES), and Italian (IT).
4. DST (Daylight Saving Time) feature is set to Auto (factory set). The
clock has been programmed to automatically switch when the daylight
saving time is in effect. User can set the DST to OFF to disable the
feature.
Disable / Enable RCC signal reception (Fig. 12)
1. Press and hold RCC button 8 seconds to disable the reception.
2. Press and hold RCC button 8 seconds to enable automatic RCC
reception.
Fig. 22
RCC signal on RCC signal off
ALARM CLOCK SETTING
Turn on/off alarm clock (and ice-alert function) (Fig. 13)
1. Press button to show the alarm time.
2. Press button twice to activate the alarm.
3. Press button three times to activate alarm with ice-alert function.
4. To disable the alarm, press button until the alarm icons disappear.
Fig. 23
Alarm off Alarm on Alarm and ice-alert on
NOTE!
1. Press SNOOZE/LIGHT button when alarm sounds to interrupt the
alarm. The alarm will then start again after 5 minutes.
2. Pres button when alarm sounds to deactivate the alarm until next
time.
Alarm time setting
1. Press and hold button for 2 seconds to enter alarm setting mode.
Hours will begin to flash.
2. Use or button to adjust the desired value and press button
to proceed to set minutes.
3. Repeat step 2 to set minutes, then press button to exit.
NOTE!
Press button twice when alarm time is being displayed will activate
the temperature-adjusted pre-alarm (ice-alert). The alarm will sound 30
minutes earlier if it detects outside temperature is below -3°C.
WEATHER FORECAST
The device contains sensitive pressure sensor built-in with sophisticated
and proven software that predicts weather for the next 12 hours.
sunny, clear slightly cloudy cloudy rainy rainy, stormy snowy
Fig. 24
NOTE!
1. The accuracy of a general pressure-based weather forecast is about
70% to 75%.
2. The weather forecast is meant for the next 12 hours, it may not
necessarily reflect the current situation.
3. The “Snowy” weather forecast is not based on the atmospheric
pressure, but based on the outdoor temperature. When the outdoor
temperature is below -3°C (26°F), the “Snowy” weather indicator will
be displayed on the LCD.
4. The icon will flash on the screen when the rainstorm comes.
BAROMETRIC / ATMOSPHERIC PRESSURE
Atmospheric Pressure is the pressure at any location of the Earth caused
by the weight of the column of air above it. One atmospheric pressure
refers to the average pressure and gradually decreases as altitude
increases. Meteorologists use barometers to measure atmospheric
pressure. Since variation in atmospheric pressure greatly affected by
weather, it is possible to forecast the weather by measuring the changes
in pressure.
Select display mode
1. Press and hold button for 2 seconds to enter atmospheric pressure
setting mode.
2. Use or button to select between absolute and relative
atmospheric pressure:
• ABSOLUTE the absolute atmospheric pressure of your location
• RELATIVE the relative atmospheric pressure based on the sea level
Set relative atmospheric pressure value
1. Get the atmospheric pressure data of the sea level (it is also the
relative atmospheric pressure data of your home area) through the local
weather service, internet and other channels.
2. Press and hold button for 2 seconds until ABSOLUTE or RELATIVE
flashes.
3. Press or button to switch to RELATIVE mode.
4. Press button again and the number for RELATIVE flashes.
5. Use or button to change the value.
6. Press button to save and exit the setting mode.
NOTE!
1. The default relative atmospheric pressure value is 1013 mb/hPa
(29.91 inHg), which refers to the average atmospheric pressure.
2. When you change the relative atmospheric pressure value, the weather
indicators will change along with it.
3. The built-in barometer can notice the environmental absolute
atmospheric pressure changes. Based on the data collected, it can
predict the weather conditions in the forthcoming 12 hours. Therefore,
the weather indicators will change according to the detected absolute
atmospheric pressure after you operate the clock for 1 hour.
4. The relative atmospheric pressure is based on the sea level, but it
will change with the absolute atmospheric pressure changes after
operating the clock for 1 hour.
Select barometer measurement unit
Press button several times until the desired measurement unit is
displayed: inHg, mmHg or hPa.
TEMPERATURE & HUMIDITY
Comfort Indication
The comfort indication is a pictorial indication based on indoor air
temperature and humidity in an attempt to determine comfort level.
Fig. 25
too cold, too dry comfortable too warm, too humid
HINWEIS!
1. Comfort indication can vary under the same temperature, depending
on the humidity.
2. There is no comfort Indication when temperature is below 0°C (32°F)
or over 60°C (140°F).
13

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bresser 7902510 Weather Center 5-in-1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bresser 7902510 Weather Center 5-in-1 in de taal/talen: Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bresser 7902510 Weather Center 5-in-1

Bresser 7902510 Weather Center 5-in-1 Gebruiksaanwijzing - Nederlands - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info