MEASUREMENT INTERVAL
Powered by DC adapter
The device measures PM2.5 or PM10 concentration every minute automatically when
powered with a DC adapter.
Manual detection
User can press [CHECK] button anytime to get an updated measurement of PM2.5 or PM10
concentration readings. (It takes approximate 10-12s to detect, the readings indicated by
blinking PM2.5/PM10 icon.)
Operated by batteries
When powered by batteries, it’s detecting every 10 minutes by default. To maximize the bat-
tery life, user can also change the detection interval from 10 minutes to 20 or 30 minutes.
Setting default mearurement interval
1. Press and hold [CHECK]for2secondsuntilthedisplayisashing
2. Press [MODE] to choose which interval time.
3. Thesettingsequence:10m‣20m‣30m
4. Press [CHECK]tonishthesettingandgobacktonormaldisplay.
Detection interval (Minute) Description
1 (when connected to adapter) The sensor will detect the PM value every 1 minute
10 (default) The sensor will detect the PM value every 10 minutes
20 The sensor will detect the PM value every 20 minutes
30 The sensor will detect the PM value every 30 minutes
PM2.5/PM10 CONCENTRATION
For easy visualization of air quality, the device spreads the concentration readings over 6 level scale.
The following provides some given health guidelines on activities between good and
hazardous air quality*:
PM2.5 PM10 Healthy persons Elderly, Children,
Pregnant Women Persons with chronic disea-
se or heart disease
0~35 0~35 Continue with normal activities Continue with normal activities Continue with normal activities
36~53 51~75 Continue with normal activities Continue with normal activities Continue with normal activities
54~70 76~100 Reduce prolonged or strenuous
outdoor physical exertion
Minimize prolonged or strenuous
outdoor physical exertion
Minimize prolonged or strenuous
outdoor physical exertion
71~150 101~350 Avoid prolonged or strenuous
outdoor physical exertion Minimize outdoor activity Avoid outdoor activity
151~250 351~420 Minimize outdoor activity Avoid outdoor activity Avoid outdoor activity
251+ 420+ Avoid outdoor activity Avoid outdoor activity Avoid outdoor activity
Good
Hazardous
* Always consult/check with your doctors for any medical advices concerning the air quality and your health.
Note:
This 6 level scale of PM2.5 / PM10 concentration is not the same as Air Quality Index (AQI).
BATTERY POWER STATUS
The device is powered by rechargeable batteries, and comes with battery power indicator.
The battery life of the device from fully charged batteries is determined by the number of
detections it performed, either through set intervals or manually activated by user.
100% 80% 60% 40% 20% < 20%
When battery power fails to below 20%, user should recharge the batteries by connecting to
a USB port using the cable provided.
Note:
When the wireless PM2.5/PM10 air quality sensor’s battery power is below 20%, its
detection function will temporary suspension.
CHARGING BATTERY
You can use the micro USB cable to charge the wireless PM2.5/PM10 sensor if the battery
states show in “Low battery”. When Micro USB port plug in the micro USB cable for
charging, the LCD will display andashingbatteryicon.
:
:
Charging underway
Charged to full capacity
Note:
- Charged to full capacity from <20% battery power status require 24 hours.
REPLACE THE RECHARGEABLE BATTERIES
Over time, the batteries may degrade in terms of holding the highest capacity for which it
wasdesignedfor.Ifyoundthedevice´sbatterypowerisnotlastingasitusedtobe,it´s
probably a good time to change them.
1. Unscrew and
remove the battery
door of sensor with
a screwdriver.
2. Pull the black ribbon
lying under the bat-
teries. All batteries
can be removed
together.
3. Insert new 3 x AA size rechargeable batteries into the battery compart-
ment according to the polarity mark inside battery compartment.
4. Screw the battery door compartment on tightly.
5. After inserting batteries, all LCD segment will be shown for 1 second.
Note:
Please prepare a screwdriver for removing and close the battery door.
PAIRING WIRELESS SENSORS TO CONSOLE DISPLAY
This Wireless PM2.5/PM10 Air Quality Sensor can connect to the Air Quality Display console.
1. After powering up the wireless air quality sensor, it will automatically enter
registration mode for 10 minutes until which it can be paired by the display console.
2. Once the connection is successful, the signal strength indication and PM2.5/PM10
infromation will appear on the display console.
Note:
- If you need to re-assign the sensor channel, slide the channel slide switch to the new
cahnnel position, then use a pin to press [RESET] key to restart the sensor.
- To avoid the sensor(s) and console pairing failure during new channel number assigned
andsetup,pleasepowerupthesensor(s)rst,andthenpress[SENSOR]keyonthemain
unit.
- After connected to the console display, the reading will transmit every 12 seconds in the
rst5minutes.Everyreadingtransmission,thesymbolofsignaltransmission , will
ash0.5secondsatonce.
VIEW DATA ON CONSOLE
You can view the readings of your PM2.5/PM10 sensor(s) on the console receiver to which
the sensor(s) is linked to. Readings can then be analyzed into averages of past 24 hours or
maximums of past 1 hour, 24 hours, or since its last reset.
DATA TRANSMISSION
Thedevicetransmitsitsupdatedreadingatxedintervalof60secondstothepaired
console receiver.
RESET THE SENSOR
In case of malfunction, use a pin to press [RESET] button to reset the sensor.
SENSOR INSTALLATION
The sensor is designed for desktop or wall mount for easy viewing. Follow the guidelines
below for the sensor placement.
1. Choose an open area away from any emissions source of pollutants, heat source, or
withairowgreaterthan1m/s.
2. Place the wireless PM2.5/PM10 sensor at least 1.5m to 4m above the ground to better
illustrate the detection of air quality in the human breathing zone.
3. Do not expose the sensor to direct sunlight.
Wall mounting
Sensorcanbemountedonthewallatdierent
angle, either at slant angle or vertically with the
mounting adapter (included).
Place a screw on the wall where you wish to hang for sensor. Hand the sensor on to the
screw with or without the mounting adaptor.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bresser 7009970 Air Quality Sensor bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bresser 7009970 Air Quality Sensor in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 2.21 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info