729922
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
OVERVIEW
MAIN UNIT
12
563
49
10 117
8
1
2
1. LCD display
2. [ SNOOZE / LIGHT ] key
- When alarm is sounding, press to stop the current alarm and enter snooze.
- When alarm is sounding, press and hold for 2 seconds to stop the current alarm, the
clock will sound again in the next day.
3. [ HISTORY ] key
- In normal mode, press to display the past 24 hour pressure records.
4. [ MEM ] key
- In normal mode, press to check maximum and minimum thermo-hygro reading, or
press and hold for 3 seconds to delete both records.
5. [ 12/24 /
] key
- In normal mode, press to switch between 12 or 24 hour format of time display, or
press and hold for 3 seconds to activate wireless sensor pairing mode.
- In setting mode, press to decrease the setting values.
6. [ CH /
] key
- In normal mode, press to switch between CH 1~3 of outdoor sensor’s weather
display, or press and hold for 2 seconds to enter auto-cycle mode.
- In setting mode, press to increase the setting values.
7. [ TIME ] key
- In normal mode, press to switch between alarm 1 and alarm 2, or press and hold for
2 seconds to enter time setting mode.
- In time setting mode, press to step the setting.
8. [ ALARM ] key
- In normal mode, press to turn on/o alarm1 and alarm 2, or press and hold for 2
seconds to enter alarm setting mode.
- In alarm setting mode, press to step the setting.
9. [ °C / °F ] key
- In normal mode, press to switch between Celsius and Fahrenheit, or press and hold
for 3 seconds to receive the RC signal once.
10. [ BARO ] key
- In normal mode, press to switch between hPa (mb) and inHg, or press and hold for 3
seconds to enter the “rel” and “abs” switch mode.
11. [ RESET ] key
- In case of malfunction, press to reset the main unit.
12. Battery compartment
LCD DISPLAY
1. Ch. 1-3 temperature & humidity
reading
2. Indoor temperature & humidity
reading
3. Weather forecast, Baro pressure
& moon phase section
4. Time and calendar section
1
2
3
4
WIRELESS THERMO-HYGRO SENSOR
1. LED indicator
- Flashes when the remote unit is
transmitting.
2. LCD display
- to show the detected temperature or
humidity of the sensor.
3. Wall mounting holder
4. [ RESET ] key
- Press to restart the sensor.
5. [ CHANNEL ] slide switch
- Assign the transmitter to Channel
from 1 to 3.
6. Battery compartment
- Accommodates 2 x AA size batteries.
GETTING STARTED
WIRELESS SENSOR
1. Remove the battery door.
2. Insert 2 x AA size batteries into the battery compartment. Make sure you insert
them the right way according to the polarity information marked on the battery
compartment.
3. Replace the battery door.
The sensor will now start transmitting signals, and LED indicator ashes.
NOTE:
- Once the channel is assigned to a sensor, you can only change it by removing the
batteries or resetting the sensor, you also need to press and hold [ 12/24 /
] key for
3 seconds on main unit to pair this sensor.
- After replacing the batteries of the wireless sensor or the unit fails to receive wireless
sensor signal of a specied channel, you need to press and hold [ 12/24 /
] key for 3
seconds on main unit to pair this sensor again.
- Avoid placing the transmitter in direct sunlight, rain or snow.
- The building material and the position of the receiver and transmitter aect the
eective range. So try various locations to obtain the best result.
- Place the units away from metal objects and electrical appliances to minimize the
interference. Position the receiver and transmitter within the eective transmission
range: 30m in usual circumstances.
MAIN UNIT
1. Remove the battery door and insert 2 x AA batteries into the battery compartment,
according to the polarity mark on the battery compartment.
2. After the batteries are installed, all LCD segment will be shown.
3. Press the [ RESET ] key of main unit rst.
4. Replace the battery door.
5. After 5 minutes channel searching, it will turn to RC signal reception automatically.
6. Radio Controlled function, the current time & date automatically synchronized with
the time signal transmitted from Germany (DCF77) or UK (MSF).
NOTE:
- If no display appears on the LCD after installing the batteries, press the [ RESET ] key
by using a metal wire.
- You may not receive the RCC and wireless sensor(s) signal immediately. Due to the
atmospheric disturbance, the best reception often occurs during night time.
VIEW MULTIPLE WIRELESS SENOR CHANNELS
1. In normal mode, press [ CH /
] key to switch the display between CH 1~3.
2. In normal mode, press and hold [ CH /
] key for 2 seconds to enter auto-cycle
mode, After a “bi” sounds, it will alternately displays the CH 1~3 at 4 second intervals.
3. During auto-cycle mode, press [ CH /
] key again to stop auto-cycle mode and
display the current channel.
RECEPTION OF RADIO CONTROLLED SIGNAL
The time and date are radio-controlled. The current time and date are automatically
synchronized with the time signal transmitted from Germany (DCF77) or UK (MSF).
When used for the rst time (after inserting the batteries or pressing the [ RESET ]
key), the clock will start to receive the RC signal after 5 minutes with the signal strength
indicator ashing. You can also press and hold [ °C / °F ] key with 3 seconds to receive
the RC signal once.
RCC SIGNAL INDICATOR
The signal indicator shows signal receive status. The signal receiving status could be
classied into 2 types:
No RCC signal received Receiving RCC signal Received RCC signal
NOTE:
- Every day the wireless sensor will automatically search for the time signal at 2:00 ,
3:00, 4:00 and 17:00.
- Always place the unit away from interfering sources such as TV set, computer, etc.
- Avoid placing the unit on or next to metal plate.
- Closed area such as airport basement, tower block or factory is not recommended.
- Do not start reception on a moving article such as vehicle or train.
- User can permanent disable or enable the RC function by press and hold the
[SNOOZE/LIGHT] key for 8 seconds, once the setting complete, the ON or OFF icon
will show on the LCD.
DAYLIGHT SAVING TIME (DST)
This clock has been programmed to automatically switch when the daylight saving time is
in eect. User can disable the DST function in time and calendar setting mode.
NOTE:
DST AUTO/OFF setting only available when RCC function is ON.
TIME AND CALENDAR SETTING
1. In normal mode, press and hold [ TIME ] key for 2 seconds to enter date and time
setting mode.
2. Press [ CH /
] or [ 12/24 / ] key to adjust the setting.
3. Press [ TIME ] key to enter the next setting.
4. The setting sequence: year
DM / MD month day DST AUTO / OFF
hour minute second weekday language ± 23 Hour oset.
5. Press [ TIME ] key or leave the unit for 30 seconds to complete the setting and return
to normal mode.
6. Weekday language GB
FR DE ES IT
GB
Instruction Manual
Wetterstation • Weather station
TENDENCE WSX
Art. No. 7006405
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bresser 7006405 TENDENCE WSX bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bresser 7006405 TENDENCE WSX in de taal/talen: Engels als bijlage per email.

De handleiding is 0,37 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bresser 7006405 TENDENCE WSX

Bresser 7006405 TENDENCE WSX Snelstart handleiding - Nederlands - 20 pagina's

Bresser 7006405 TENDENCE WSX Gebruiksaanwijzing - Deutsch - 3 pagina's

Bresser 7006405 TENDENCE WSX Snelstart handleiding - Français - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info