MIN records. The display sequence is: outdoor MAX temperature &
humidity outdoor MIN temperature & humidity current channel’s
indoor MAX temperature & humidity current channel’s indoor MIN
temperature & humidity MAX average MAX gust MAX dew
point MIN dew point MAX wind chill MIN wind chill MAX heat
index MIN heat index MAX UV index MAX Beaufort MAX
pressure MIN pressure MAX rain rate.
2. Press and hold [ MAX / MIN ] key for 2 seconds to reset all the MAX/
MIN records.
WEATHER WARNING/ALERT
Weather Alert can alert you of certain weather conditions. Once the alert
criterion is met, the alarm sound will activate and the LCD’s alert icon
will ash.
To set the alert
1. In normal mode, press and hold [ ALERT ] key for 2 seconds to enter
alert setting mode
2. During alert setting mode, press [ ALERT ] key to switch to the next
items in the sequence below:
Alert Setting
Range
Display Section Default
Value
Outdoor Temperature
High
-40°C ~ 80°C
Outdoor tempe-
rature & humidity
section (OUT-
DOOR)
40°C
Outdoor Temperature Low 0°C
Outdoor Humidity High
1% ~ 99%
80%
Outdoor Humidity Low 40%
Indoor Temperature High
-40°C ~ 80°C
Indoor tempera-
ture & humidity
section (INDOOR)
40°C
Indoor Temperature Low 0°C
Indoor Humidity High
1% ~ 99%
80%
Indoor Humidity Low 40%
Wind Speed
0.1m/s ~
50m/s
Wind direction
& speed section
(WIND)
172mm/h
Pressure Drop (within 30
minutes)
1hPa ~ 10hPa
Barometer section
(BARO)
3hPa
Rainfall 1mm ~ 1000
mm
Rainfall section
(RAINFALL)
100 mm
3. Press [ GRAPH / ] or [ °F / °C / ] key to adjust the value or press
and hold the key to change rapidly
4. After completing the rainfall alert setting, press [ ALERT ] key to save
and exit the setting mode
To activate the alert
1. In normal mode, press and hold [ ALERT ] key for 2 seconds to enter
alert setting mode
2. During alert setting mode, press [ ALARM ] key to toggle the regarding
alert
3. After setting Rainfall Alert, press [ ALERT ] key to save and exit the
setting
NOTE!
1. The unit will automatically exit setting mode in 5 seconds if no button
is pressed.
2. When ALERT alarm is on, the area and type of alarm that triggered the
alarm will be ashing and the alarm will sound for 2 minutes.
3. Press ALARM/SNOOZE button when alarm sounds to interrupt the
alarm. The alarm will then start again after 5 minutes.
POINTING 6-IN-1 SENSOR TO THE SOUTH
The 6-in-1 outdoor sensor is calibrated to be pointing to North by de-
fault. However, in some cases, users may wish to install the product with
the arrow pointing towards the South, especially for people living in the
Southern hemisphere (e.g. Australia, New Zealand).
1. First install the 6-in-1 outdoor sensor with its arrow pointing to the
South. (Please refer to 'Installation' chapter for mounting details)
2. Press and hold INDEX button for 8 seconds. Press the INDEX button
again until the N Symbol (Northern hemisphere) is blinking.
3. Use
or button to change to lower part (Southern hemisphere).
4. Press INDEXT button again to conrm and exit.
NOTE!
Changing from hemisphere setting will automatically switch the direction
of the moon phase on the display.
MOON PHASES
In the Northern hemisphere, the moon waxes (the part of the moon we
see that glows after the New Moon) from the right. Hence the sun-lit area
of the moon moves from right to left in the Northern hemisphere, while in
the Southern hemisphere, it moves from left to right.
Below are the 2 tables which illustrate how the moon will appear on the
main unit.
Northern hemisphere:
New moon Full moon
Waxing crescent Waning gibbous
First quarter Third quarter
Waxing gibbous Waning crescent
Southern hemisphere:
New moon Full moon
Waxing crescent Waning gibbous
First quarter Third quarter
Waxing gibbous Waning crescent
SUNRISE & SUNSET TIME
The main unit indicates your locations sunrise & sunset time by the time
zone, latitude and longitude you entered. Please insert the correct infor-
mation in the related settings. If the latitude and longitude values do not
match the time zone, the sunrise & sunset time cannot be shown.
TROUBLESHOOTING
Problem/Symptom Solution
Strange or no measure-
ment of rain sensor
1. Check drain hole in the rain collector.
Clean it if neccessary.
2. Check the circular level. Realign the
device if neccessary.
Strange or no measure-
ment of Thermo/Hygro
Sensor
1. Check radiation shield. Clean it if
neccessary.
2. Check sensor housing. Clean it if
neccessary
and --- (no signal
for 15 minutes)
1. Relocate main unit and 6-in-1 sensor
closer to each other.
2. Make sure the main unit is placed
away from other electronic appliances
that may interfere with the wireless
communication (TV‘s, computers,
microwaves).
3. If problem continues reset both, main
unit and 6-in-1 sensor.
and ER (no Signal for
1 hour)
SPECIFICATIONS
Main unit
Main power DC 5V 1A
Type: XLJXA-E050100
Batteries (backup) 3 x AAA, 1.5 V
Barometer unit hPa, inHg, mmHg
Barometer measuring range 540 - 1100 hPa
DE
EN
17

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Bresser-7002540-PROFI-W-LAN-WETTER-CENTER

Zoeken resetten

  • graag een nederlands talige handleiding w-lan wetter center artikel no 7002540 graag sturen naar info@veluwegroen.nl
    bij voorbaat dank Cees van Ee
    Gesteld op 3-12-2020 om 08:41

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bresser 7002540 PROFI W-LAN WETTER CENTER bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bresser 7002540 PROFI W-LAN WETTER CENTER in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 5,18 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bresser 7002540 PROFI W-LAN WETTER CENTER

Bresser 7002540 PROFI W-LAN WETTER CENTER Gebruiksaanwijzing - Français - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info