41. Barometer reading
42. Barometer measurement unit (hPa / inHg / mmHg)
43. Alarm on
Rainfall (Fig. 15)
44. Time range record indicator
45. HI Alert and alarm on
46. Current rainfall rate
47. Rainfall unit (in / mm)
Multifunctional histogram (Fig. 16)
48. Histogram variable
49. Histogram
50. Hourly records indicator
BEFORE YOU START
IMPORTANT!
1. Insert batteries for the main unit before doing so for the 6 in 1 outdoor
sensor.
2. Place the main unit as close as possible to the remote unit.
3. Position the remote unit and main unit within the effective transmis-
sion range.
When changing batteries always change batteries in the main unit as well
as all remote units and replace them in the correct order, so the remote
connection can be re-established. If batteries are exchanged in only one
of the devices (i.e. the remote sensor) the signal can’t be received or
can’t be received correctly.
Note, that the effective range is vastly affected by building materials and
position of the main and remote units. Due to external inuences (var-
ious RC devices and other sources of interference), the maximum dis-
tance can be greatly reduced. In such cases we suggest to position the
main unit and the remote sensor at other places. Sometimes all it takes
is a relocation of one of these components of a few inches!
POWER SUPPLY
Main unit (Fig. 19)
1. Plug the DC power adaptor (D) into the DC jack (25)
2. Press RESET key to re-start the main unit
3. After reset, all LCD segments will show on the display for a short mo-
ment before the unit enters the AP (access point) setup mode and the
LED lights green.
Insert backup batteries (optional)
1. Open the battery compartment door.
2. Install 3 batteries (AAA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
The Main unit LED indicator can show the following status:
Status LED status
AP (access point) mode for setup ash green
light
Connected to Wi-Fi router blue light
Search the Wi-Fi router / Connection failed ash blue
light
Firmware update ash red light
Manual sensor pairing mode by pressing the [Wi-Fi /
Sensor] key
ash cyan
light
Refresh the upload data and sync internet time by
pressing the [Refresh] key
ash purple
Indoor sensor (Fig. 3)
1. Open the battery compartment door.
2. Install 2 batteries (AA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
NOTE!
1. If you need to re-assign the sensor channel, rstly slide the channel
slide switch to the new channel that you want, then press the [SEN-
SOR] button on the main unit and then press the [RESET] button on the
sensor to pair the sensor with the main unit again.
2. Avoid placing the sensors in direct sunlight, rain or snow.
3. To avoid the sensor's and main unit pairing failure during new setup,
please power up the sensor's rst, and then press the [RESET] button
on the main unit (not on the sensor's).
6-in-1 Multi Outdoor sensor (Fig. 20)
1. Open the battery compartment door.
2. Install 3 batteries (AA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
NOTE!
The LED will begin ashing every 12 seconds.
Low battery warning
When it is time to replace the batteries, the respective low battery indi-
cator
will be shown near to the Indoor temperature and humidity
display (batteries for main unit) or near to the Outdoor temperature and
humidity (batteries for remote sensor).
INSTALLATION
Indoor sensor
Use the mounting hole on the back of the sensor to install it on the wall
using a screw. You can also place the sensor directly to e.g. a table.
6-in-1 Multi Outdoor sensor (Fig. 17-18)
Install the wireless 6-in-1 Multi Outdoor sensor in an open location with
no obstructions above and around the sensor for accurate rain and wind
measurement. Install the sensor with the smaller end facing the North to
properly orient the wind direction vane.
Secure the mounting stand and bracket (included) to a post or pole, and
allow minimum 1.5m off the ground.
Fig. 17: Mounting on pole (Pole Diameter 50.8 mm (approx. 2“)).
Fig. 20: Circular level.
Mounting guidelines:
1. Install the wireless 6-in-1 sensor at least 1.5m off the ground for better
and more accurate wind measurements.
2. Choose an open area within 150 meters from the LCD display main
Unit.
3. Install the wireless 6-in-1 sensor as level as possible to achieve accu-
rate rain and wind measurements. A circular level device is provided to
ensure a level installation.
4. Mount the wireless 6-in-1 sensor with the wind meter end pointing to
the North to correctly orient direction of the wind vane.
Step 1:
Plug the stainless steel moun-
ting pole into the sensor's
mounting hole and tighten the
screws.
Screws
Step 2:
Fasten the stainless steel
tube on your x pole with 2
U-bolt, pole mounting clamps
and nuts.
U-bolt
Mounting
clamp
DE
EN
13

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Bresser-7002540-PROFI-W-LAN-WETTER-CENTER

Zoeken resetten

  • graag een nederlands talige handleiding w-lan wetter center artikel no 7002540 graag sturen naar info@veluwegroen.nl
    bij voorbaat dank Cees van Ee
    Gesteld op 3-12-2020 om 08:41

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bresser 7002540 PROFI W-LAN WETTER CENTER bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bresser 7002540 PROFI W-LAN WETTER CENTER in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 5,18 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bresser 7002540 PROFI W-LAN WETTER CENTER

Bresser 7002540 PROFI W-LAN WETTER CENTER Gebruiksaanwijzing - Français - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info