632904
20
Verklein
Vergroot
Pagina terug
1/72
Pagina verder
20
Soil moisture sensor (Fig. 3, 5)
1. Registration
1) Place the soil sensor next to the gateway
2) Enable your WiFi reception on your iOS / Android device and run the “BRESSER Connect” app
3) Select “Garden” and then tap the “ i ” on the upper right corner to enter the setting display
4) Tap “OK” in the [Install a new sensor now?] or tap “Sensor list” and tap “+” to add a new sensor
5) Tap “Connect” on the app to search for the soil sensor.
6) Pull out the plastic strip from the battery compartment (or insert 1 piece of CR2450 battery inside the battery
compartment) of the soil sensor within 30 seconds after tapping the “Connect”. Once connection is established,
“Sensor is connected” appears and you have successfully registered your soil sensor. You may proceed to change
the name & photo. Tap the “Save” icon on the upper right corner anytime to save and exit.
7) Return to the “Garden” main display. Swipe up or down and the soil moisture readings will appear.
2. Setup
1) Select a location for the soil sensor that is within the effective transmission range (30 meter in open area). Reduce
distance if obstacles are between the soil sensor and the gateway.
- Remove the protecting tube from the soil sensor (fig. 7, B). Always clean the 2 metal pins located on the bottom of
the probe before use or taking another reading from a different pot or location
- Softly push the probe into soil to avoid damage to the 2 metal pins located at the front of the probe
- Insert the probe straight up as vertically as possible. If you are using a pot, insert about halfway between the plant
stem and the edge of the pot. For pots over 12 inch diameter, position the probe about a third of the way between the
stem and the edge of the pot.
- Push the probe down until the soil moisture sensor (or soil temperature sensor) reaches the root (or seedbed) level
or about two thirds of the depth of the pot. Never insert the probe beyond the level as shown in fig. 7 (A).
2) If your sensor is within the effective transmission range, the soil moisture reading will remain on the screen after
25 minutes of setup. If “---“ reading appears or “sensor is not connected” appears on its setting page after 25 minutes
of setup, your soil sensor is out of range. Shorten the distance between the sensor and the gateway. Go to the
“garden” setting page and tap [Connect] again to reconnect the sensor. Repeat this procedure until the sensor is
connected.
NOTE: If you have run the BRESSER Connect system for a long period of time, and one day your soil sensor fails to con-
nect with the system while the rest of the sensors work fine, it’s likely that the battery level in the soil sensor is low. Please
check the sensor and if the low battery icon appears on the LCD display, please reinstall new batteries and follow the setup
procedure in the manual to reconnect with your BRESSER Connect system
Notes:
The soil sensor measures electric current flowing between the 2 metal pins on the probe and converts the signal into
soil moisture level indication. Due to the fact that electrical conductivity varies between different type & density of soils
and fertilizers as well as the positioning & depth of the probe, the moisture level reading may vary accordingly and this is
normal. The soil moisture level is to provide general reference of the soil moisture condition only and the manufacturer
does not take any liability for any loss or damage caused to your plants.
The soil sensor may not be able to measure the soil moisture accurately for very coarse or grave soils due to possible
non-conductive air gaps or spacing hidden inside the soil. In this case the soil moisture reading may be lower than ex-
pected and this is normal.
The sensing cycle of the soil moisture is around 10 minute. After watering, wait for around 10 minute or more before the
soil moisture level is updated on display and allow time for the water to penetrate into the soil for about 10 minutes.
The operating temperature range of soil sensor is 0°C to 50°C. Accurate measurements and proper function of the sen-
sors are not guaranteed when parts of the BRESSER Connect are out of the range of the operating temperature.
WATERING
Different plants require different level of soil moisture. Some plants prefer drier soil conditions and some like to be kept moist.
20

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bresser 70-20000 Connect Set bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bresser 70-20000 Connect Set in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 4,16 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info