This model stores the last 9 temperature measurements.
To display the stored measurement, the thermometer must
be turned on.
Press the Mem button.
The display shows the temperature, and when releasing the
Mem button, the stored temperature for that memory number
is displayed, together with “M”.
Each time the Mem button is pushed, the stored
reading and an M is displayed to indicate each
temperature measurement (eg. M2).
Memory mode is automatically exited by
not pressing the memory button for 5 seconds.
In the cases below, wait 20 minutes prior to taking a temperature.
Factor A ects
Extreme hot and cold room temperature
Hearing aid
Lying on pillow
Use the untreated ear if ear drops or other ear medications have been placed in the ear canal.
Memory mode
1
1
2
3
6520
6520
Night light feature
The thermometer includes a convenient night light to illuminate
the display in a dim environment.
The light will turn on when you press any button. It will stay on until the
thermometer is inactive for up to 15 seconds even after temperature is
taken.
The last temperature taken is stored in its memory
and will be automatically displayed for 5 seconds
when it is turned on again.
Changing the temperature scale
Your Braun ThermoScan is shipped with the Celsius (°C) temperature scale
activated. If you wish to switch to Fahrenheit (°F) and/or back from Fahrenheit
to Celsius, proceed as follows:
Make sure the thermometer is turned o .
Press and hold down the Power button
. After about 3 seconds
the display will show this sequence: °C / SET / °F / SET.
1
2
Care and cleaning
The probe tip is the most delicate part of the thermometer.
It must be clean and intact to ensure accurate readings.
If the thermometer is ever accidentally used without a lens  lter, clean the
probe tip as follows:
Very gently wipe the surface with a cotton swab or soft cloth moistened
with alcohol. After the alcohol has completely dried out, you can put a new
lens  lter on and take a temperature measurement.
If the probe tip is damaged, please contact Consumer Relations.
Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners.
Never submerge this thermometer in water or any other liquid. Store thermometer and lens  lters
in a dry location free from dust and contamination and away from direct sunlight.
Additional lens  lters (LF 40) are available at most stores carrying Braun ThermoScan.
Replacing the batteries
The thermometer is supplied with two 1.5 V type AA (LR 06) batteries. For
best performance, we recommend Duracell
®
alkaline batteries.
Insert new batteries when the battery symbol appears on the display.
Open the battery compartment. Remove the batteries and replace with
new batteries, making sure the poles are in the right direction.
Snap battery door into place.
1
2
3
Only discard empty batteries. To protect the environment, dispose of
empty batteries at your retail store or at appropriate collection sites
according to national or local regulations.
Calibration
This device was designed and manufactured for a long service life, however it is generally
recommended to have the device inspected once a year to ensure correct function and accuracy.
Please contact the authorized service centre located in your country.
Note: The calibration checking is not a free service. Please contact the Authorized Service Centre to
get a quotation before you send out the product.
Manufacturing date is given by the LOT number located in the battery compartment.
The  rst three (3) digits after LOT represent the Julian date that the product was manufactured and
the next two (2) digits represent the last two numbers of the calendar year the product was
manufactured. The last identi ers are the letters that represent the manufacturer.
An example: LOT 11614k, this product has been manufactured on the 116th day of the year 2014.
Release the Power
button when the desired temperature scale is shown.
There will be a short beep to con rm the new setting, then the thermometer is turned o
automatically.
3
English
6

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Braun-ThermoScan-7---IRT6520

Zoeken resetten

6
12

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Braun ThermoScan 7 - IRT6520 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Braun ThermoScan 7 - IRT6520 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Turks als bijlage per email.

De handleiding is 9,59 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info