If a permanent connection is required
A disconnector must be provided on the
installation side. Switches with a contact
opening of more than 3 mm and all-pole
disconnection are regarded as disconnectors.
This includes LS switches, fuses and contactors.
Electrical specications
The required connection data can be found on
the rating plate inside the appliance when the
grease lters have been removed.
Length of the power cord: approx. 1.30 m.
This extractor hood complies with the EC
interference suppression regulations.
ELECTRICAL CONNECTION
Before connecting the appliance to the
power supply, always follow the instructions
and warnings in the chapter entitled ”Safety
instructions”!
The extractor hood may only be connected
by a qualied electrician who is familiar with
the regulations of the relevant electricity
supply company.
ṇ RISK OF INJURY
If the power cord of the extractor hood is
damaged, it must be replaced by the
manufacturer, his customer service or a
similarly qualied person to prevent hazardous
situations.
The extractor hood may be connected to a
correctly installed earthed socket only.
The earthed socket must be attached in the
indicated area.
– The earthed socket should be connected via
its own circuit.
– If the earthed socket is no longer accessible
following installation of the extractor hood,
a disconnector must be tted as for a
permanent connection.
Installation instructions