780636
11
Verklein
Vergroot
Pagina terug
1/24
Pagina verder
Settings Customer level
Rego 1000 – 6 721 831 662 (2021/03) en 11
To set the desired time of day:
Select Program 1 or Program 2.
Go to menu 1.1.11.2 View/edit active program.
Select day by turning the menu dial.
Fig. 24
Press the menu dial to mark the value to be changed.
Fig. 25
Turn the menu dial until the desired setting has been selected.
Then press the menu dial.
Turn the menu dial to be able to set additional values in the same way
as above.
Go back one step with .
Select Saving alternative:
Return without saving
Program 1
Program 2
The set changes are saved as a selected program or not at all.
To adjust the normal temperature, proceed to menu 1.1.11.3 Room
temperature normal.
To adjust the exceptional temperature, proceed to menu 1.1.11.7
Room temperature exception.
Room temperature program when there is a room sensor:
1.1.11 Room temperature program
1.1.11.1 Active program
If a program is selected, the following (if the menu button is turned) is
displayed:
1.1.11.2 View/edit active program
1.1.11.3 Room temperature normal
Set the desired set point for the room temperature.
1.1.11.6 Room temperature influence
Set the values in the same way as for1.1.10.1 Room temperature
influence .
1.1.11.7 Room temperature exception
Set the temperature that should apply as exceptional temperature in
the program.
The menu is only displayed if Program 1 or Program 2 is selected.
1.1.11.8 Copy to all heating circuits
Select Yes to have the same control for all installed circuits.
The menu is displayed only under Circuit 1 .
Room temperature program when there is no room sensor:
1.1.11 Room temperature program
1.1.11.1 Active program
1.1.11.2 View/edit active program
The same as when there is a room sensor, see above.
1.1.11.3 Room temperature normal
Set the measured value in the room.
The indicated value is used by temperature programs to calculate the
difference between normal and exceptional temperature.
1.1.11.4 Temperature increase/decrease
Use this function to adjust the room temperature so that the normal
room temperature (see the previous menu) becomes the desired
temperature.
Use this function to simply increase or decrease the heat when there
are no room sensors.
– Results in approx. 1 °C lower room temperature.
– results in approx. 0.5 °C lower room temperature.
+ results in approx. 0.5 °C higher room temperature.
++ results in approx. 1 °C higher room temperature.
1.1.11.6 Room temperature influence
Set the values in the same way as for 1.1.10.1 Room temperature
influence .
1.1.11.7 Room temperature exception
The same as when there is a room sensor, see above.
1.1.11.8 Copy to all heating circuits
The same as when there is a room sensor, see above.
1.3 Circuit 2 (option)
Set the values in the same way as for 1.1 Circuit 1 Heating .
1.4 Circuit 3 (option)
Set the values in the same way as for 1.1 Circuit 1 Heating .
1.5 Circuit 4 (option)
Set the values in the same way as for 1.1 Circuit 1 Heating .
6.2.1 Set point value
The heating circuit's set point value is the temperature of the flow that
the heat pump attempts to maintain. Sometimes, the measured actual
value fluctuates a bit upward and downward depending on changes in
the outdoor temperature or a large hot water demand.
The set point value is normally based on:
Current curve value (the low line temperature at the current outdoor
temperature according to the applicable heat curve).
Current curve influence through:
Room sensor
Holiday
Active program
Program Day Start Stop
Program 1, 2 Mon - Sun 5:30 22:00
Table 7 Program 1 and 2
6 720 643 415-13.1I
6 720 643 415-14.1I
It always takes some time for a change of a heating
setting, e.g. an increase or decrease in room
temperature, to apply. The same applies in the event of a
quick change of the outdoor temperature. This is why
you should always wait for at least 24 hours before
making a new change.
The set point value specified by the customer/installer is
most often the room temperature, which is recalculated
by the control unit into a corresponding flow
temperature set point value. Under normal conditions, 1
K ( °C) in room temperature corresponds to approx. 3 K
( °C) in flow temperature.
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bosch Rego 1000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bosch Rego 1000 in de taal/talen: Engels als bijlage per email.

De handleiding is 4.13 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info