English - 1
The machine is intended for cutting, roughing and
brushing metal and stone materials without using
water. For cutting stone, a cutting guide is re-
quired.
Slots in structural walls are subject to the Stand-
ard DIN 1053, Part 1 or country-specific regula-
tions.
These regulations are to be observed under all
circumstances. Before beginning work, consult
the responsible structural engineer, architects or
the construction supervisor.
Measured values determined according to
EN 50 144.
Typically the A-weighted noise levels of the ma-
chine are: Sound pressure level: 90 dB (A);
sound power level: 103 dB (A).
Wear hearing protection!
The typical hand/arm vibration is below 2.5 m/s
2
(1.7 m/s
2
).
Tool Specifications
Angle Grinder GWS 21-180 HV
PROFESSIONAL
GWS 21-230 HV
PROFESSIONAL
GWS 24-180 BV
PROFESSIONAL
Order number 0 601 851 B.. 0 601 852 B.. 0 601 853 B..
With residual current-limit control GWS 21-180 JHV
PROFESSIONAL
GWS 21-230 JHV
PROFESSIONAL
GWS 24-180 JBV
PROFESSIONAL
Order number 0 601 851 G.. 0 601 852 G.. 0 601 853 G..
Rated input power* [W] 2 100 2 100 2 400
Output power [W] 1 350 1 350 1 700
No-load speed [rpm] 8 500 6 500 8 500
Grinding disc dia., max. [mm] 180 230 180
Grinder spindle thread M 14 M 14 M 14
Weight without cable, approx. [kg] 4.4 4.4 5.2
Protection class / II / II / II
Angle Grinder GWS 24-230 BV
PROFESSIONAL
GWS 26-180 BV
PROFESSIONAL
GWS 26-230 BV
PROFESSIONAL
Order number 0 601 854 B.. 0 601 855 B.. 0 601 856 B..
With residual current-limit control GWS 24-230 JBV
PROFESSIONAL
GWS 26-180 JBV
PROFESSIONAL
GWS 26-230 JBV
PROFESSIONAL
Order number 0 601 854 G.. 0 601 855 G.. 0 601 856 G..
Rated input power* [W] 2 400 2 600 2 600
Output power [W] 1 700 1 800 1 800
No-load speed [rpm] 6 500 8 500 6 500
Grinding disc dia., max. [mm] 230 180 230
Grinder spindle thread M 14 M 14 M 14
Weight without cable, approx. [kg] 5.2 5.2 5.2
Protection class / II / II / II
Please observe the order number of your machine. The trade names of the individual machines may vary.
Inrush currents cause short-time voltage drops. Under unfavourable power supply conditions, other equipment may be
affected. If the system impedance of the power supply is lower than 0.25 Ohm, disturbances are unlikely to occur.
* The values given are valid for nominal voltages [U] of 230/240 V. For lower voltages and models for specific countries,
these values can vary.
Intended Use
Information on Structures
Noise/Vibration Information
15 • 1 609 929 F55 • TMS • 18.12.03