544370
15
Verklein
Vergroot
Pagina terug
1/157
Pagina verder
English | 15
Bosch Power Tools 1 609 929 U13 | (17.8.12)
Noise/Vibration Information
Measured noise values determined according
to EN 12549.
Typically the A-weighted noise levels of the pneumatic tool
are: Sound pressure level 96 dB(A); sound power level
110 dB(A). Uncertainty K=2 dB.
Wear hearing protection!
Vibration total values a
h
and uncertainty K determined ac-
cording to EN ISO 20643: a
h
< 2.5 m/s
2
, K= 1.5 m/s
2
.
Declaration of Conformity
We declare under our sole responsibility that the product
described under “Technical Data” is in conformity with the
following standards or standardization documents:
EN 792 according to the provisions of the directive
2006/42/EC.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 16.08.2012
Assembly
Connecting the Air Supply (see figure A)
Make sure that the pressure of the compressed-air system
is below the maximum permitted rated pressure of the
pneumatic tool. Firstly, set the air pressure to the lower
value of the recommended rated pressure (see “Technical
Data”).
When in doubt, check the pressure at the air inlet with a
pressure gauge with the pneumatic tool switched on.
For maximum performance, the values for the supply-air
hose 17 (connection thread, maximum operating pres-
sure, inner hose diameter, maximum hose length; see
“Technical Data”) must be observed.
The compressed air supplied should be free of foreign ma-
terial and moisture to protect the tool from damage, con-
tamination, and the formation of rust.
All fittings, connecting lines and hoses must be dimen-
sioned for the pressure and the required air volume.
Avoid restrictions in the air supply, e.g., from pinching,
kinking, or stretching!
Connecting the Air Supply to the Pneumatic Tool
Empty the magazine 8.
(See “Emptying the Magazine”, page 15)
For the following worksteps, a fastener can be dis-
charged when interior parts of the pneumatic tool are
not in the starting position due to repairs, maintenance
or transport.
Connect the air connector 6 with a supply-air hose 17
equipped with an air-connection coupling 16.
Check the proper function by placing the outlet 13 or
the rubber workpiece protector 1 of the pneumatic tool
onto a piece of scrap wood or wood material, and dis-
charging once or twice.
Loading the Magazine
Disconnect the air supply before making
any adjustments, changing accessories,
or placing the pneumatic tool aside. This
safety measure prevents accidental start-
ing of the pneumatic tool.
f Use only original Bosch accessories (see “Technical
Data”). The precision parts of the pneumatic tool such
as the magazine, the outlet and the shot duct are
matched to Bosch staples, nails and brads. Other man-
ufacturers use other steel qualities and sizes.
Using fasteners not permitted, can damage the pneu-
matic tool and cause injuries.
While loading the magazine, hold the pneumatic tool in
such a manner that the outlet 13 is not pointed at your own
body or at other persons.
GTK 40 (see figures B1B2)
Pull back the magazine slider 11 until the button of mag-
azine-slider lock 7 fully engages.
Clean and lubricate the magazine slider 11 as required
and make sure that the magazine 8 is not dirty/soiled.
Place a fitting strip of staples 18 over magazine 8.
The staple heads must face completely flush against the
surface of the magazine and the staple strips must move
easily in the magazine.
Lightly pull back magazine slider 11 and press the but-
ton of magazine-slider lock 7 inward.
Carefully guide the magazine slider to the front until it
touches the staple strip.
Note: Do not let the magazine slider snap back without
guiding it. Otherwise, the magazine slider could become
damaged, and there is danger of your fingers being caught
or pinched.
GSK 50 (see figures C1C2)
Press magazine lock 14 and at the same time pull maga-
zine 8 toward the rear to the stop.
Clean and lubricate magazine rail 20 as required.
Insert a fitting nail strip 19.
If possible, the nail tip should touch the magazine rail
20.
Slide the nail strip in the magazine all the way to the
front.
Insert the magazine until magazine lock 14 engages
again.
Refill the magazine when the red bars of refill indicator 15
can be seen halfway.
Operation
Actuation systems
The pneumatic tool can be operated with two different ac-
tuations systems:
Single actuation with safety run
With this actuation system, the discharge lock-off 2
must first be firmly pressed against the workpiece. A
fastener is not discharged until the trigger 10 is pulled.
Afterwards, further discharging procedures can only be
actuated, when the trigger and the discharge lock-off
have first been set back to the starting position.
Contact actuation
With this actuation system, the trigger 10 must be
pulled first. A fastener is always discharged when the
discharge lock-off 2 is firmly pressed against the work-
piece while the trigger is pressed.
This enables a higher working speed to be achieved.
The actuation system is set via the selector switch 9.
Starting Operation
Disconnect the air supply before making
any adjustments, changing accessories,
or placing the pneumatic tool aside. This
safety measure prevents accidental start-
ing of the pneumatic tool.
Working with Single Actuation (see figure D)
Press selector switch 9 inward and at the same time piv-
ot it to the bottom position until it engages.
The actuation system “single
actuation” is set.
Release the selector switch 9 again.
Firmly position the outlet 13 or the rubber workpiece
protector 1 on the workpiece until discharge lock-off 2
is pressed in completely.
Afterwards, briefly press trigger 10 and release again.
A staple (GTK 40) or a brad (GSK 50) is discharged.
Allow the pneumatic tool to bounce back from the work-
piece.
For another driving procedure, completely lift the pneu-
matic tool from the workpiece and position it firmly at
the next desired location.
Working with Contact Actuation (see figure E)
Press selector switch 9 inward and at the same time piv-
ot it to the upper position until it engages.
The actuation system
“contact actuation” is
set.
Release the selector switch 9 again.
Press and hold the trigger 10.
Firmly position the outlet 13 or the rubber workpiece
protector 1 on the workpiece until discharge lock-off 2
is pressed in completely.
A staple (GTK 40) or a brad (GSK 50) is discharged.
Allow the pneumatic tool to bounce back from the work-
piece.
For another driving procedure, completely lift the pneu-
matic tool from the workpiece and position it firmly at
the next desired location.
Move the pneumatic tool uniformly over the workpiece
by lifting it off and applying it again.
Each time when applying the pneumatic tool while the
discharge lock-off is pressed in, a staple (GTK 40) or a
brad (GSK 50) is discharged.
As soon as the desired amount of staples (GTK 40) or
brads (GSK 50) have been driven in, release trigger 10
again.
Working Advice
Disconnect the air supply before making
any adjustments, changing accessories,
or placing the pneumatic tool aside. This
safety measure prevents accidental start-
ing of the pneumatic tool.
Check the proper function of the safety and actuation de-
vices, and the tight seating of all screws and nuts each time
before using.
Disconnect a defective or not properly operating pneumat-
ic tool immediately from of the air supply and contact an
authorised service agent for Bosch power tools.
Do not perform any incorrect manipulations on the pneu-
matic tool. Do not disassemble or block any components of
the pneumatic tool, such as the discharge lock-off.
Do not carry out “emergency repairs” with unsuitable
means. The pneumatic tool is to be maintained regularly
and properly (see “Maintenance and Cleaning”, page 16).
Avoid any weakening and damage whatsoever of the pneu-
matic tool, e.g., through:
Imprinting or engraving,
Retrofitting measures not approved by the manufactur-
er,
Guiding along templates manufactured of hard material,
e.g. steel,
Dropping on or sliding over the floor,
Using as a hammer,
Applying any kind of force.
Make sure to check whatever is below or behind your work-
piece. Do not shoot staples (GTK 40) or brads (GSK 50) in-
to walls, ceilings or floors, when persons are behind them.
The fasteners can burst through the workpiece and injure
someone.
Do not shoot a staple (GTK 40) or brad (GSK 50) on al-
ready driven-in fasteners. This could cause the fastener to
deform, the fasteners could become jammed or the pneu-
matic tool could move uncontrolled.
When the pneumatic tool is used under cold ambient con-
ditions, the first staples (GTK 40) or brads (GSK 50) are
driven in slower than usual. Once the pneumatic tool has
warmed up during working, normal operating speed will be
regained.
Avoid blank shots in order to reduce the wear of the impact
striker.
For longer work breaks or after finishing work, disconnect
the pneumatic tool from the air supply and empty the mag-
azine.
Emptying the Magazine
GTK 40
Pull back the magazine slider 11 until the button of mag-
azine-slider lock 7 fully engages.
Remove staple strip 18.
Dr. Egbert Schneider
Senior Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
OBJ_BUCH-1038-003.book Page 15 Friday, August 17, 2012 10:59 AM
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bosch GTK 40 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bosch GTK 40 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Turks, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 16,63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info