15
Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
Setting the DHW alternating operation
If DHW alternating operation is not activated, DHW heating has priority
and interrupts the heat requirement of the heating system, if necessary.
Menu: DHW alternating operation
Table 11 Settings for the DHW alternating operation
Settings for the DHW circulation
Menu: Circulation
Table 12 Settings for the circulation
3.3.3 Settings for the venting function
Menu: Ventilation
Table 13 Ventilation settings
3.3.4 Setting up a holiday program
Menu: Holiday
CAUTION
Risk of system damage!
Before a prolonged period of absence, only change the settings
under Holiday.
After a long absence, check the operating pressure of the heating
system and check the pressure gauge of the solar system if
applicable.
Do not switch off the solar system during long absences.
Cooling mode will not be activated during a holiday program.
Menu: Holiday 1, Holiday 2, Holiday 3, Holiday 4 and Holiday 5
Menu item Description
DHW alt.
operation on
In the event of simultaneous DHW and heating
demand, the system will alternate between DHW
heating and heating mode based on the times set in
[Prioritise DHW for] and [Heating priority for].
Prioritise DHW
for
Duration of DHW heating.
Heating priority
for
Duration of heating mode.
Menu item Description
Op. mode [Off]: Circulation is switched off permanently.
[On]: The pump will run according to the settings under
[Start frequency]. The time program for the DHW
circulation pump is not active.
The circulation can be linked to the time program for
DHW heating.
[My circulation time prog.]: Set a time program for the
DHW circulation pump that works independently of the
time program for DHW.
Start frequency The start frequency determines how often the DHW
circulation pump goes into operation for three minutes at a
time every hour (1 x 3 minutes/h ... 6 x 3 minutes/h) or if it
is constantly in operation. Whatever the case, circulation is
only active during the times set in the time program.
My circulation time
prog.
6 switching times can be set for each day or group of days.
The DHW circulation pump can be switched on or off at
each switching time. The minimum duration of a time slot
between two switching times is 15 minutes.
Resetting prog. The time program is reset to factory default.
Menu item Description
Op. mode [Select vent. operating mode.]
[Sleep]
[High vent. rate] (high ventilation rate)
[Auto (time program)]
[Demand-ctrlled] (demand controlled)
[Ex.air bypass] (exhaust air bypass)
[Party vent.] (party ventilation)
[Firepl.] (fireplace)
[Fan speed 1 ... 4]
[Ventil. switched off] (ventilation off)
Time program [Enter vent. time program.]
Reset time prog. [Reset ventilation time program.]
Humidity [Setting the desired humidity level]:
•[Dry]
•[Normal]
•[Moist]
Air quality [Setting the desired air quality level:
•[Adequate]
•[Normal]
[High]
Bypass [Bypass] for more opening hours:
•[Open]
•[Close.]
Supply air temp.
control
Set the [Supply air temp.]:
[Heating]
[HtgCool] (heating and cooling)
[Cooling]
•[Off]
Supply air temp.
control (Electric)
Set the [Supply air temp.]:
[Heating]
•[Off]
Reheat supp.air
temp.
[Set the desired supply air temp. of reh. bank.]
10 ... 22 ... 30 °C
Filter timer [Set the time in months until the next filter change.]
1 ... 6 ... 12 Months
Confirm filter
change
The filters in the ventilation unit must be changed.
Please confirm the filter change.
Rename ventil.
zone
The names of the ventilation zones can be changed
in the same way as the names of the heating
circuits. This helps in choosing the right ventilation
zone.
Menu item Description
Holiday period Set the start and end date of the absence during
holiday: the holiday program starts at the set start
time at 00:00 o'clock. The holiday program ends at
the set end time at 24:00 o'clock.
Selection of htg
circ./DHW
The holiday program is applied to the sections of the
system highlighted here. Only the heating circuits
and DHW systems actually installed in the system
are available for selection.
Heating Control of the room temperature for the selected
heating circuits during the holiday period:
Any [Constant temperature] can be set for the
selected heating circuits throughout the entire
holiday period.
The [Off ]setting deactivates the heating system
completely for the selected heating circuits.
Menu item Description
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bosch Compress 7400i AWE bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bosch Compress 7400i AWE in de taal/talen: Engels als bijlage per email.

De handleiding is 4.98 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bosch Compress 7400i AWE

Bosch Compress 7400i AWE Installatiehandleiding - Deutsch - 28 pagina's

Bosch Compress 7400i AWE Gebruiksaanwijzing - Deutsch - 28 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info