11
pressure.
- We recommend that you clean the device
after each time nished using.
- Clean the equipment regularly with a moist
cloth and some soft soap. Do not use cleaning
agents or solvents; these could attack the
plastic parts of the equipment. Ensure that
no water can seep into the device.
8.2 Air filter (B10-11)
In this connection, please also read the
service information.
- Clean the air lter at regular intervals, and
replace it if necessary.
- Remove xing bolt on the air lter cover
(B10).
- Remove the lter elements (B11).
Important!
Do not use abrasive cleaning agents or petrol
to clean the elements.
- Clean the elements by tapping them on a
at surface. In cases of stubborn dirt rst
clean with soapy water, and then rinse with
clear water and air dry.
- Assemble in reverse order.
8.3. Spark plug (B9)
Check the spark plug (item 18) for dirt and
grime after 50 hours of operation and if
necessary clean with a copper wire brush.
Thereafter service the spark plug after every
50 hours of operation.
- Pull off the spark plug boot with a twist.
- Remove the spark plug with the supplied
spark plug wrench (19).
- Assemble in reverse order.
8.4 Changing the oil and checking the oil level
(B12-B14)
The motor oil is best changed when the
Engine is at working temperature.
- Only use motor oil SAE - 15W40 / (<0
O
C)
[SAE - 5W30].
8.4.1 Fill up Oil. (B12)
- Open the oil ller plug by screw it off (9).
- Add exactly 0.6L engine oil with an oil lling
jug.
Or refer to content in 8.4.2.
- Screw the Oil ller plug back.
8.4.2 Checking Oil level. (B13)
- Place the generator on a slightly inclined
surface so that the dip stick is at proper
position.
- Screw off the Oil Filler plug and wipe off
any oil on the dip stick.
- Put the oil dip stick back without screw into
the Oil ller.
Important!
Do not screw the dipstick in to check the oil
level; simply insert it up to the thread.
- Check the dip stick; make sure the oil level
is between “H” and “L” mark.
8.4.3 Let out used Oil (B14)
- Open the oil ller plug (8).
- Screw off the oil drain nut (9) and let the hot
engine oil drain out into a drip tray.
- After the old oil has drained out, close the
oil drain plug and place the generator on a
level surface again.