Appropriate use
Clean the extractor hood thoroughly prior to first use. As is the case prior to any other cleaning and servicing, pull the
power plug or disable the circuit breaker to disconnect the unit from power.
Lamps can become very hot when operated. Disconnect the extractor hood from power and allow lightbulbs to
cool down before replacing lightbulbs!
The extractor hood should only be operated with installed lightbulbs. Always switch on the extractor hood
when using a stove top burner. Condensate can form if the hood is switched off, potentially resulting in
corrosion damage on the equipment.
An extractor hood is not a shelf! Do not place objects on the extractor hood..
FIRE HAZARD
You should neither flambee nor work with an open flame under the hood. The flames can be pulled into the filter
by the airflow created when the extractor hood is switched on, in which case the deposits on the grease filter can
ignite. Fire hazard!
The extractor hood must only be installed above fireplaces that can create a fire hazard due to airborne sparks if
the fireplace has a closed, non-removable enclosure and in all cases meets country-specific regulations.
Never leave pots, pans, and fryers unattended when preparing meals with oil and grease, such as French fries.
Oil and grease are easily ignitable!
Regularly cleaning the grease filter and changing the activated carbon filter routinely will mitigate a fire hazard.
The extractor hood must never be operated without a grease filter.
OPERATING MODES – EXHAUST AIR AND RECIRCULATING AIR
Instructions for exhaust air mode
Exhaust air is evacuated to the outside either upward by an air duct or directly through an exterior wall.
NOTE: The exhaust air must be discharged neither through an operational smoke or exhaust chimney nor
through a duct used to ventilate installation rooms for fireplaces. The approval of a competent chimney sweep
specialist must be obtained before the exhaust air can be routed through a non-operational smoke or exhaust
chimney. The regulatory and statutory regulations must be observed when discharging exhaust air (for example
regional construction codes). A telescoping wall sleeve should be used when the exhaust air is routed through
the exterior wall.
The extractor hood achieves its best possible performance with a short, straight exhaust pipe and the largest
possible pipe diameter. If pipe bends cannot be avoided, the radii should be made as large as possible.
In exhaust air mode, it is particularly important that the air volume collected from the room can be made up
unrestricted. The otherwise resulting negative pressure can substantially reduce the extraction performance.
The pressure equalization steps required for this purpose are mandatory in this case. This is either accomplished
with an appropriate makeup air opening with at least the same cross-section as the exhaust air opening or by
using a window switch that only allows the extractor hood to be operated when the
window is opened and/or tilted.
Diverters and reductions
Turbulence and backflows are created on reductions and diverters. These can further reduce the backpressure and
increase the noise profile, while also reducing the efficiency of the extractor hood. The use of at least one elbow is
generally unavoidable. However, as a general rule, the fewest possible number of diverters should be used, while re
-
ductions and sharp angles should be avoided whenever possible. For instance, the use of two bends with large radii
(> 90°) results in a far lower airflow performance reduction than one 90° elbow. However, the installation must always
take into account that different individual resistances are created depending on the shape of round pipe, hoses
and flat duct, diverters and reductions. These are cumulative and result in a reduction of the airflow volume and in
increased operating noise. We therefore recommend keeping the line as short and straight as possible and using the
lowest possible number of reductions, and taking the location and design of the exhaust airline into consideration
when specifying the airflow volume.
DIN EN 6191 defines a metering arrangement for determining performance, which specifies an exhaust airline
typically used in practice, along with the resulting backpressures. The following pipes are connected to the exhaust
flange of the hood:
- a vertical pipe section with a length of 300 mm
- a 90° elbow
- a horizontal pipe section with a length of 1000 mm
NOTE: Using long, rough exhaust air pies, many pipe bends, or pipe diameters below 150 mm results in a variance
from the optimal air output and in increased noise levels. The exhaust air line must only be routed using pipes and
hoses made from non-combustible materials. The manufacturer of the stove hoods assumes no warranty liability
for claims in connection with the planning and layout of the pipe assembly.
Pipe connections
The diameter of the exhaust pipes should not be below 150 mm.
Round pipes: We recommend an inner diameter of 150 mm, and min. 120 mm.
Flat ducts must have the same inner cross section as round pipes. They should not have sharp changes in direction.
Ø 150 mm approx. 177 cm
Ø 120 mm approx. 113 cm
Sealing strips should always be used for deviating pipe diameters.
Diameter of exhaust pipe connection: 150 mm (recommended size)
Attach the exhaust air directly on the air pipe flange and seal appropriately. Smooth out the interface area first
when using aluminum pipes.
GB
14

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bielmeier BHG52 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bielmeier BHG52 in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 2,62 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info