809088
34
Verklein
Vergroot
Pagina terug
1/36
Pagina verder
CAUSES REASONS SOLUTIONS
The water flow sensors work
without pressing the filter or heat
button.
1. The water flow sensor flags didn’t fall back into the
correct position.
2. The water flow sensors are broken.
1. Unplug the plug gently, strike the side of the pump but not violently, and plug it
back in.
2. For assistance, please visit the support section on our website,
www.bestwaycorp.com.
After starting or during the
functions of filtering or/and
heating, the water flow sensors do
not detect water flow.
1. You forgot to remove the 2 stopper caps from
inside the pool.
2. Filter cartridges are dirty.
3. Activate the filter or heat system and put your
hand in front of the outlet pipe inside the pool to
check if you can feel water flowing out.
a. If no water flows out the water pump is broken.
b. Water flows out but the alarm appears,
the water flow sensors are broken.
4. Filter blockage
5. Bent pipes or poor water flow through the plastic
pipes of the liner
6. Debris screens are blocked: debris screens can
become blocked by hard water due to calcium
build-up.
7. Perished washers
The washers within the spa couplings may have
become perished or worn.
1. Remove the 2 stopper caps before heating, refer to Assembly section in the
User’s Manual.
2. Remove the filter set from inside the pool and push the filter or heat button. If
no alarm appears, clean or change the filter cartridges install the filter set
inside the pool.
3. For assistance, please visit the support section on our website,
www.bestwaycorp.com.
4. Clean the filter and check for damage. Replace or re-install as necessary. For
assistance, please visit the support section on our website,
www.bestwaycorp.com.
5. Please check through the spa connection to see if the pipes are bending. For
assistance, please visit the support section on our website,
www.bestwaycorp.com.
6. Empty the spa and place a garden hose inside the pipes to wash the debris. To
be sure all debris are removed, perform the operation from the outside and
inside of the spa.
Use a toothbrush to remove any stubborn debris.
For assistance, please visit the support section on our website,
www.bestwaycorp.com.
7. Check the washers inside the coupling for damage. Unscrew the couplings and
remove the washer for further inspection.
For assistance, please visit the support section on our website,
www.bestwaycorp.com.
The pump’s thermometer reads
the water temperature below
4°C (40°F).
1. The water temperature is lower than 4°C (40°F)
2. If the water temperature is higher than 7°C (44.6°F),
the pump’s thermometer is broken.
1. The spa is not designed to operate with water temperatures lower than
4ºC (40°F). Unplug the pump and only re-start the pump when the water
temperature reaches 6°C (43°F).
2. For assistance, please visit the support section on our website,
www.bestwaycorp.com.
The pump’s
thermometer reads the water
temperature over 50°C (122°F).
1. The water temperature is over 50°C (122°F)
2. If the water temperature is lower than 45°C (113°F),
the pump’s thermometer is broken.
1. The spa is not designed to operate with water temperatures greater than
40°C (104°F). Unplug the pump and only re-start the pump when the water
temperature reaches 38°C (100°F) or lower.
IMPORTANT: Before you re-start the pump, push the pump’s reset button.
2. For assistance, please visit the support section on our website,
www.bestwaycorp.com.
The pump’s
thermometer
connections have issues.
1. The pump’s thermometer connectors don’t work
properly.
2. The pump’s thermometer is broken.
For assistance, please visit the support section on our website,
www.bestwaycorp.com.
The manual reset thermal cut-out
has problem
The manual reset thermal cut-out trips off. 1. Unplug the pump and push the reset button, then plug the pump back in.
2. In case the alarm still remains, check the RESET BUTTON section in manual.
3. For assistance, please visit the support section on our website,
www.bestwaycorp.com.
Ground Connection Failed. 1. The ground bonding of your home has some
problem.
2. The pump has some problem.
For assistance, please visit the support section on our website,
www.bestwaycorp.com.
ERROR CODES
34
34

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bestway 60015 Palm Springs bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bestway 60015 Palm Springs in de taal/talen: Engels als bijlage per email.

De handleiding is 4.46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bestway 60015 Palm Springs

Bestway 60015 Palm Springs Gebruiksaanwijzing - Nederlands, Deutsch, English, Français, Italiano, Português, Espanõl, Polski, Svenska, Suomi - 252 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info