SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety
precaution should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS - READ AND FOLLOW
ALL INSTRUCTIONS.
WARNING:
• The spa must be supplied through an isolating transformer or
supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
• The spa must be connected to a grounded mains supply socket
with a supply cord fitted with a plug and PRCD with a tripping current
of 10mA.
• The pump must be tested before each use, to test follow the
instruction of pump.
• If the supply cord is damaged, it must be replaced by the
manufacturer, service agent or similarly qualified persons in order to
avoid a hazard.
• To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
• No part of the appliance is to be located above the bath during use.
• Parts containing live parts, except parts supplied with safety
extra-low voltage not exceeding 12V, must be inaccessible to a
person in spa pool; Parts incorporating electrical components,
except remote control devices, must be located or fixed so that they
cannot fall into the spa pool.
• The spa must be supplied by earthed power source.
Warning: Always keep plug dry, plug in with wet plug is
definitely forbidden!
• The plug shall be directly connected only to a socket-outlet of the
fixed electrical installation.
• It is necessary to have the plug accessible after installation of the
spa.
CAUTION: In order to avoid a hazard due to inadvertent resetting of
the thermal cut-out, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a circuit
that is regularly switched on and off by the utility.
After using your spa for 3-5 years, you should contact your local
qualified maintenance technician to ensure the safety and
performance of the spa. The main components, such as heating
element, air blower motor and non-return valves within the electric
unit should be checked and replaced (if necessary) by professional
persons.
• TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT
IS RAINING,THUNDERING OR LIGHTNING.
• Never wear your contact lenses when in your spa.
• Do not use spa during chemical maintenance.
• Extension cords can’t be used.
• Don’t plug or unplug the appliance if hand is wet.
Always unplug the appliance:
- before cleaning or other maintenance
- if leave it unattended on holidays
• When the appliance will be not used for a long time, such as in the
winter, the spa or pool set should be disassembled and stored
indoor.
Caution: Read the instruction before using the appliance and
installation or reassemble every time.
• Safekeeping the instruction. If instruction is missed, please contact
with manufacturer or search it in website www.bestwaycorp.com
• Warning: For electric safety, a PRCD is incorporated in the
power cord, if the leakage current is detected more than 10mA,
the device will operate and cut-off the power supply, in such
case, please unplug and stop using the spa at once. Don’t reset
the product by yourself. And you must contact the local service
agent to check and repair the product.
• This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play
with the appliance. (For EU market)
• Cleaning and user maintenance must be performed by an adult
above18 years old who is familiar with the risk of electric shock.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure
that they do not play with the appliance. (For market other than EU)
• Water attracts children; always attach a spa cover after each use.
• Do not bury cord. Locate cord to minimize abuse from lawn mowers,
hedge trimmers, and other equipment.
• Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure
that children can not use this spa unless they are supervised at all
times.
• RISK OF INJURY. Never operate spa if inlet / outlet pipes are broken
or missing. Never attempt to replace the inlet / outlet pipes. Always
consult your local Aftersales centre.
RISK OF ELECTRIC SHOCK. Install at least 2m from all metal
surfaces.
• RISK OF ELECTRIC SHOCK. Never operate any electrical
appliance when in your spa or when your body is wet. Never place
any electric appliance, such as a light, telephone, radio, or television,
within 2m of spa.
• During pregnancy, soaking in hot water may cause damage to the
fetus. Limit use to 10 minutes at a time.
TO REDUCE THE RISK OF INJURY:
A. The water in a spa should never exceed 40°C (104°F). Water
temperature between 38°C (100°F) and 40°C (104°F) is
considered safe for a healthy adult. Lower water temperatures
are recommended for young children and when spa use exceeds
10 minutes.
B. Since excessive water temperatures have a high potential for
causing fetal damage during the early months of pregnancy,
pregnant or possibly pregnant women should limit spa water
temperature to 38°C (100°F).
C. Before entering a spa, the user should measure the water
temperature with an accurate thermometer since the tolerance of
water temperature regulating device varies.
D. The use of alcohol, drugs, or medication before or during spa use
may lead to unconsciousness with the possibility of drowning.
E. Obese persons and persons with a history of heart disease, low or
high blood pressure, circulatory system problems, or diabetes
should consult a physician before using a spa.
F. Persons using medication should consult a physician before using
a spa since some medication may induce drowsiness while other
medication may affect heart rate, blood pressure, and circulation.
• TO REDUCE THE RISK OF INJURY: Never pour water with a
temperature higher than 40°C (104°F) into the spa pool directly.
• The use of alcohol, drugs, or medication can greatly increase the risk
of fatal hyperthermia. Hyperthermia occurs when the internal
temperature of the body reaches a level that is several degrees
above the normal body temperature of 37°C (98.6°F). The symptoms
of hyperthermia include an increase in the internal temperature of
the body, dizziness, lethargy, drowsiness, and fainting. The effects of
hyperthermia include failure to perceive heat; failure to recognize the
need to exit spa or hot tub; unawareness of impending hazard; fetal
damage in pregnant women; physical inability to exit the spa or hot
tub; and unconsciousness resulting in the danger of drowning.
• Electric installations should follow national wiring rules, consult a
qualified electrician with any questions.
8
Be sure to cover the spa with the spa cover whenever the
heating function is activated. Leaving the spa uncovered will
increase the heating duration required.
Please do not use the spa when ambient temperature is
lower than 4ºC (39ºF).
Power Rate
Massage Tube Power
Heat Element Power
Water Pump Power
2,000W at 20ºC 50W
220-240V AC,
2,050W at 20ºC
800W
INSTALLATION
NOTE: Drawings for illustration purpose only. May not
reflect actual product. Not to scale.
1. Insert the plug.
2. Press the “RESET” button, the indicator light turns on.
3. Press the “TEST” button, the indicator light turns off.
4. Press the “RESET” button, the indicator light turns on.
5. Press the “On/Off” button for 2 seconds, your pump is ready to use.
6. After inserting the plug, when the indicator light turns on, press the “TEST” button directly.
WARNING: The PRCD plug must be tested before each use to avoid risk of electric shock.
WARNING: Before inserting plug into a power outlet, make sure the current rate of the power outlet is suitable for the pump.
WARNING: Do not use the pump if this test fails and contact our Customer Service.
PRCD Test
RESET
TEST
2
RESET
TEST
4
RESET
TEST
1
3
RESET
TEST
303021185661/14x21cm/54112; 54113; 54123; 54129; 54148; 54154; 54171; 54174; 54175; 54183; 54186/欧规AirJet SPA说明书/
Selected Location
WARNING: The selected location has to be able to support
of supporting the expected load.
WARNING: An adequate drainage system has to be provided
to deal with overflow water for both indoor and outdoor
installations.
IMPORTANT: Because of the combined weight of the Lay-Z-Spa, water, and users, it is extremely important
that the base where the Lay-Z-Spa is installed is smooth, flat, level and capable of uniformly supporting the
weight for the entire time the Lay-Z-Spa is installed (not on the carpet or other similar material). If the
Lay-Z-Spa is placed on a surface, which does not meet these requirements, any damage caused by improper
support is not covered under the manufacturers warranty. It is the responsibility of the Lay-Z-Spa owner to
assure the integrity of the site at all times.
1. Indoor Installation:
Be aware of special requirements if you install the spa indoors.
• Humidity is a natural side effect with Lay-Z-Spa installation. Determine the effects of
airborne moisture on exposed wood, paper, etc. in the proposed location. To minimize these effects it is best to
provide plenty of ventilation to the selected area. An architect can help determine if more ventilation is needed.
2. Outdoor Installation:
• During filling, draining or when in use, water may flow out of the spa. Therefore the Lay-Z-Spa should be
installed near a floor drain.
• Do not leave the spa's surface exposed to direct sunlight for long periods of time.
To reach 40ºC (104ºF), the heating duration required is base on the starting water temperature and ambient
temperature, the data below is purely for reference. To display the current water temperature, run the filter
system for at least a minute.
Ambient Temperature
10ºC(50ºF)
15ºC(59ºF)
20ºC(68ºF)
25ºC(77ºF)
30ºC(86ºF)
Water Temperature
10ºC(50ºF)
15ºC(59ºF)
20ºC(68ºF)
25ºC(77ºF)
30ºC(86ºF)
Set Temperature
40ºC(104ºF)
40ºC(104ºF)
40ºC(104ºF)
40ºC(104ºF)
40ºC(104ºF)
Heating Duration
18.5 h
15 h
11.5 h
8.5 h
5.5 h
IMPORTANT !
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bestway 54113 Lay-Z-Spa - Monaco AirJet bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bestway 54113 Lay-Z-Spa - Monaco AirJet in de taal/talen: Engels als bijlage per email.

De handleiding is 40,79 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Bestway 54113 Lay-Z-Spa - Monaco AirJet

Bestway 54113 Lay-Z-Spa - Monaco AirJet Gebruiksaanwijzing - Nederlands - 12 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Gebruiksaanwijzing - Deutsch - 12 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Aanvulling / aanpassing - Alle talen - 2 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Snelstart handleiding - Alle talen - 40 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Gebruiksaanwijzing - Alle talen - 196 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info