Pull the first master finger over the finger sensor. 3.
The green LED will slowly flash once as a positive acknowledgement.
Pull the same finger over the finger sensor again. 4.
The green LED will slowly flash once as a positive acknowledgement.
Pull the same finger over the finger sensor again. 5.
The blue LED will go out and the green LED is illuminated.
After 2 seconds, the red LED will also be illuminated, signalling that the 6.
second master finger must be learned.
If the red LED flashes three times as a negative acknowledgement during step 3,
repeat the step until you receive a positive acknowledgement.
If the timeout elapses during the learning process, the radio finger-scan will
switch itself off and you must begin again with step 1.
NOTE:
In order to ensure operational reliability, we recommend using a fingerprint from a
different person to learn the second master finger. If both of the learned master
fingers are from the same person, we recommend learning a fingerprint from
each hand.
Learning the second master finger (M2)7.2.2
Push the cover up to the 1. second notch or press the ON button to activate the
device.
The red and green LEDs are illuminated.
Press the PRG button for at least2.
5 seconds (selection of the a. first radio code location). The red and green
LEDs will go out and the blue LED slowly flashes for the duration of the
learning process.
10 seconds (selection of the b. second radio code location). The red and
green LEDs will go out and the blue LED slowly flashes in pairs for the
duration of the learning process.
Pull the second master finger over the finger sensor. 3.
The green LED will slowly flash once as a positive acknowledgement.
Pull the same finger over the finger sensor again. 4.
The green LED will slowly flash once as a positive acknowledgement.
Pull the same finger over the finger sensor again. 5.
The blue LED will go out and the green LED is illuminated.
If the green LED is illuminated after step 3, two master fingers have been 6.
learned and the device is now in identification mode.