577177
15
Verklein
Vergroot
Pagina terug
1/83
Pagina verder
11/ 2014
BENNING CM 11
10
J
COM jack, common jack for voltage and resistance measurements as well as for continuity
testing, marked in black
K
V-Ω jack (positive), common jack for voltage and resistance measurements as well as for
continuity testing, marked in red
L
Battery compartment cover, at the rear of the housing
5. General information
5.1 General information on digital current clamp multimeter
5.1.1 The digital display
9
is designed as a 4 digit liquid-crystal indicator with 12 mm digit
height and decimal point. The highest value displayed is 5000.
5.1.2 The polarity indication on the digital display
9
works automatically. Contrary to the
measurement-wire definition, only one pole is indicated as “-”.
5.1.3 In case of a range exceedance (overflow), “0L.” is displayed.
Attention: no display or warning by complete overload.
5.1.4 The rotary switch
5
is intended for selecting the measuring function.
5.1.5 ZERO button
6
: For zero adjustment in current measure ment. Can also be used for all
ranges for differential measurement (zero setting possible for any value). Indicated by
“ZERO” in the digital display
9
.
5.1.6 The MIN/ MAX key function
7
automatically records and stores the highest and the
lowest measured value. By pressing the key, the following values are displayed: “MAX”
shows the highest value stored, “MIN” shows the lowest value stored and “MIN/ MAX”
shows the current measured value. Press the key for approx. 2 seconds to switch the
device back to normal operating mode.
In the „ / Ω“ measuring function, press the „MIN/ MAX“ key
7
to change from the
acoustic continuity test to resistance measurement.
5.1.7 HOLD key function: The measuring result can be stored by pressing the HOLD key
8
.
The “HOLD” symbol simultaneously appears on the display
9
. Press the key again to
switch the device back to measuring mode.
5.1.8 The yellow illumination key
activates the illumination of the display
9
. It is switched
off by pressing the key again or automatically after approx. 30 seconds.
5.1.9 The measuring rate of the BENNING CM 11 amounts nominally to 2 measurements per
second for the digital display.
5.1.10 The BENNING CM 11 is switched on and off with the rotary switch
5
. Shutdown posi-
tion “OFF”.
5.1.11 The BENNING CM 11 switches off automatically after approx. 15 minutes (APO, Auto-
Power-Off is activated, if the symbol is shown on the display
9
). It switches on
again, if the rotary switch
5
is switched on again from switch position „OFF“ or if the
yellow illumination key
is pressed. It switches on again, if the HOLD key
8
or another
key is actuated. Automatic switch-off can be deactivated by pressing the HOLD key and
by simultaneously switching on the BENNING CM 11 from the switching position “OFF”.
The symbol disappears from the display
9
.
5.1.12 The BENNING CM 11 is supplied by two 1.5 V batteries (IEC LR03/ AAA/ micro).
5.1.13 If the battery voltage drops below the specified operating voltage of the BENNING CM 11,
then a battery symbol appears in the display
9
.
5.1.14 The battery life depends on the measuring function used and is approximately 30 hours
to 100 hours without using the acoustic continuity test and background lighting (alkaline
battery).
5.1.15 Temperature coefficient of the measured value: 0.1 x (stated measuring accuracy)/ °C
< 18 °C or > 28 °C, related to the value for the reference temperature of 23 °C
5.1.16 Dimensions of unit (length x width x height) = 206 x 76 x 33,5 mm.
Weight of unit: 262 g (incl. batteries)
5.1.17 The safety measuring leads and measurement tips supplied are spe cially suited to the
rated voltage of the BENNING CM 11. The measuring tips can be protected by caps.
5.1.18 Widest prong opening: 23 mm
6. Ambient conditions
- The BENNING CM 11 is intended for making measurements in dry environment.
- Maximum barometric elevation for making measurements: 2000 m,
- Overvoltage category: IEC 60664/ IEC 61010 → 300 V category IV
- Contamination class: 2 (EN 61010-1),
- Protection class: IP 30 (DIN VDE 0470-1, IEC/ EN 60529)
IP 30 means: Protection against access to dangerous parts and protection against solid
impurities of a diameter > 2.5 mm, (3 - first index). No protection against water, (0 - second
index).
- Operating temperature and relative humidity:
For operating temperatures from 0 °C to 40 °C: relative air humidity lower than 80 %, non-
condensing
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Benning CM11.0 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Benning CM11.0 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Pools, Turks als bijlage per email.

De handleiding is 2,55 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info