Bell• res wishes you many cosy evenings with your new Bell• res gas • re
This document is an essential part of your gas • re. Read it carefully before
installation and maintenance of the gas • re and keep it in a safe place!
INSTALLATION INSTRUCTIONS &
MANUAL FOR MAINTENANCE
YORK LARGE 3
CF/LF
Gas • re with closed combustion system
Serial number:
Production date:
3
Bell res English
Installation instructions
BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM:
York Large 3 CF (Centre Fire) (YKL3 CF)
York Large 3 LF (Line Fire) (YKL3 LF)
4
Bell res English
Installation instructions
5
Bell res English
Installation instructions
CONTENTS
Page
1. INSTALLATION INSTRUCTIONS .............................................................. 7
2. MAINTENANCE .....................................................................
...................
. 67
3. FAULTS ...................................................
.................................
...
.
...
..........
. 68
4. DISMANTLING / ASSEMBLING OF THE GLASS
.
....................
.
..
...
.......
... 69
5. DIAGRAM ELECTRICITY AND GAS ........................
........................
......... 75
6. DIMENSIONS ......................................................
..............................
....
....
. 76
7. TECHNICAL DETAILS/REGULATIONS .....................................
..
..
...
......... 84
8. REPLACEMENT PARTS LIST .........................................
..........
..
...
..
.
........ 88
9. DISPOSAL OF PACKAGING AND APPLIANCE .........
......................
...
.....
. 91
The installation must only be carried out by a
“Gas Safe Register” registered installation engineer.
IMPORTANT
6
Bell res English
Installation instructions
7
Bell res English
Installation instructions
1 INSTALLATION INSTRUCTIONS
1.1 GENERAL
The gas fi re must be positioned and connected as a “room sealed system” (balance
ue) appliance by a “Gas Safe Register” registered gas installation engineer in
accordance with the following installation instructions, nationally and locally applicable
regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have
any queries regarding the installation, please consult your local gas company.
Important: Before beginning the installation, check that the details on the
rating plate correspond to the gas type and pressure to which
the appliance will be connected.
The appliance is supplied with a “Centre Fire” or “Line Fire” double burner, as ordered.
These burners each have their own specifi c fl ame image which is defi ned by the
perforation pattern in the burner cover. See Chapter 5 and the Instructions for use.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the
correct level of consumption.
Depending on the requested version, the appliance will be delivered from the factory
with a Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm concentric connection for
extracting the fl ue gases and supply of combustion air.
It is possible to install the gas fi re with either a wall or roof outlet.
The roof connection must be carried out using the concentric fl ue system Ø100 mm -
Ø150 mm. The fumes are exhausted naturally to the outside environment through the
inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm
and Ø150 mm pipes.
The wall connection must be carried out using the concentric fl ue system Ø130 mm -
Ø200 mm. The fl ue gases are evacuated outside by means of natural draft through the
internal pipe of Ø130 mm, whereas the combustion air is supplied between the pipes of
Ø130 mm and Ø200 mm. The wall outlet itself is, depending on the concentric fl ue gas
system confi guration, Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm. (In some cases,
with a wall connection, a complete concentric fl ue system Ø100 mm - Ø150 mm is also
possible (see Chapter 1.6.1).)
The gas fi re can be installed in a completely sealed or mechanically ventilated house
without extra ventilation and/or fume extraction.
The gas fi re is installed as a built-in appliance in a fi replace.
In order to prevent the ! replace heating up excessively, it must be properly
ventilated by installing vents at the top and bottom of the fi replace.
8
Bell res English
Installation instructions
The appliance can be fi tted with a convection package as an optional extra. This is a
convection top plate for on top of the appliance, two fl exible aluminium pipes and two
built-in convection vents. This enables hot air to be circulated into the room.
If required, two additional convector grills can be fi tted (= 1x extra convection set).
If an existing chimney is to be used, please consult your installer fi rst. If the chimney
was previously used for a wood or coal fi re, then it should be cleaned by an expert.
1.2 CONCENTRIC FLUE SYSTEMS Ø100 MM - Ø150 MM AND
Ø130 MM - Ø200 MM : Bell! res (Muelink & Grol system)
Poujoulat (PGI system)
Ontop (Metaloterm US system)
The gas fi re, in combination with the concentric fl ue system [Ø100 mm - Ø150 mm] and/
or [Ø130 mm - Ø200 mm] (rigid and/or fl exible)
for the brands Bellfi res (Muelink & Grol
system), Poujoulat (PGI system) or Ontop (Metaloterm US system), has been approved
in accordance with the European CE-norm for gas appliances and may therefore be
used only with these systems. The permitted components for these systems are listed
in Chapter 1.6.2. The guarantee on the appliance lapses if it is installed, fully or partially,
with other components or a different fl ue system.
The concentric fl ue [Ø100 mm - Ø150 mm] and [Ø130 mm - Ø200 mm] systems can be
used with either a newly-built or existing chimney.
N.B. If any part is missing, please contact your dealer.
1.3 INCLUDED
Set documentation - Instructions for use
- Installation instructions
Attributes - Ceramic log set, or
marble pebbles white or marble pebbles grey
- Hook (for opening the frame and the glass)
9
Bell res English
Installation instructions
Part no Option
Convection package York Large 3
331456 1x Convection casing
330714 1x Top plate Convection
312829 1x Convection set General
331295 Black mirror, rear wall YKL3
329707 Black mirror sidewall DYL3/YKL3
332167 Fins set YKL3
330361 Set of high adjustable feet (4 pieces)
311967 Mantle iron, L = 1250 mm
1.4 OPTIONS AND ACCESSORIES
The following options and accessories can be supplied by your dealer:
Part no Accessorie
302092 Adapter receiver 6 VDC
312829 Convection set General: (for convection air extraction)
302188 1x Flexible aluminium pipe Ø125 mm, L= 3 m (max.)
310178 2x Fitting box 135 x 135 mm
309872 2x Convection exit grid, white, 145 x 145 mm
309730 2x Collar adaptor Ø125 mm
304040 4x Hose clamp Ø125 mm
329874 Set carrying brackets (2 pieces)
3........ Bellfi res (M&G) concentric fl ue system
See component summary
3........ Poujoulat (PGI) concentric fl ue system
See component summary
3........ Ontop (Metaloterm US) concentric fl ue system
See component summary
10
Bell res English
Installation instructions
1.5 PREPARATION FOR INSTALLATION
The following preparation must be carried out before the gas fi re can be installed.
1.5.1 Instructions for positioning the outlet
1.5.1.1 Positioning the outlet for correct operation:
Roof-mounted outlet:
Figure 1: Roof-mounted outlet
This must be positioned at least 0.5 m from the roof edge;
the apex of the roof can be disregarded.
Wall-mounted outlet:
Figure 2: Wall-mounted outlet
This must be positioned at least 0.5 m from:
the corner of the building.
the roof overhang, the rain gutter.
balconies etc., unless the exhaust construction
extends to at least the face of the protruding section.
>0.5 m
>0.5 m
11
Bell res English
Installation instructions
1.5.1.2. Positioning the outlet to avoid affecting the surrounding area
All listed “distances” in this section are no more than
guidelines.
For the exact minimum “distances”, please consult your
national and local directives.
“Distance” = minimum distance required for positioning of the outlet to avoid
adverse effects with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom.
B. A heating air supply, when the supply ! ows through an occupied room.
C. A window that can be opened and that is near an occupied room, a toilet
or a bathroom.
Roof-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At the same roof level. >3 m (*)
At a different roof level. >1 m (*)
At a lower positioned wall. >1 m
At a higher sloping surface. >3 m (**)
(*) If the required distance cannot be achieved, the outlet position rules take
precedence.
(**) If the required distance cannot be achieved, the position of the outlet must
be at least 1 m above the highest facade/roof.
12
Bell res English
Installation instructions
Wall-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At walls in buildings with staggered Not permitted if A, B, or C are located
heights. above the outlet.
On a wall - general. (*) Above the outlet: >2 m
Below the outlet: >0.75 m
Left and right of the outlet: >0.75 m
At <1 m from the roof overhang. >2 m
Beneath balconies, walkways etc. >2 m from the underside of the
protruding balcony or walkway.
Beneath balconies, walkways >2 m
etc. where the outlet extends to
the front.
To the garden or on the terrace. >2 m to the outside space. (**)
With respect to a facing wall. >2 m (if the distance from the facing
wall is less, the criteria detailed for
“On a wall - general” apply).
Enquire at your local gas company for the regulations relating to outlets
positioned opposite each other and outlet(s) in facade(s) that form an angle.
(*) These minimum distances do not apply if there is an obstruction
between the outlet and A, B and C that protrudes at least 0.5 m from
the wall and has a length exceeding the distance.
(**) This distance is not required if the outlet is situated at least 1 m
higher than the intended area of the outside space.
If the outlet has a clearance of less than 0.5 m from the hard surface of a public area at
a height of less than 2 m, it must be fi tted with an effective protector. The mesh size of
the guard must not affect the correct operation of the appliance.
13
Bell res English
Installation instructions
Use as a wall support Use as a ! oor support
36
36
1.6 GENERAL SERVICES
1.6.1 The Fume Channel/Combustion Air Intake
The combined fume channel and combustion air intake requires one of the following
concentric ! ue system con" gurations.
Important: Due to the high temperature of the outer walls
(approx. 150°C), no fl ammable materials may be located
or used in the vicinity of the fl ue system.
The complete fl ue system, must therefore be sleeved
with a heat resistant material after assembly.
Ventilate the covered concentric fl ue by fi tting a
grid near the fl oor and ceiling (on each fl oor).
Do not insulate the concentric fl ue.
Use the universal wall/fl oor support Ø150 mm
to attach the covering of the concentric fl ue system
[Ø100 mm - Ø150 mm], see 1.6.2, drawing number 36.
Figure 3: Application universal wall/fl oor support Ø150 mm
14
Bell res English
Installation instructions
Figure 4: Vertical roof-mounted outlet without bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
18
10, 11, 12, 13
1
4
Y
28
16
17
16
24
23
24
23
(100)
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION
POSSIBILITIES
Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y Concentric Concentric
(min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
2.0 - 4.0 m Width: Width:
B = 30 mm B = 65 mm
York Large 3
4.0 - 12.0 m Width: Width:
B = 40 mm B = 80 mm
15
Bell res English
Installation instructions
Figure 5: Vertical roof-mounted outlet with bend
(*) : (Y1 + Y2) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
16
23
Y2
X
10, 11, 12, 13
14, 15
Y1
4
1
28
23
23
17
24
(100)
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 (*) Concentric Concentric
(min.-max.) (min.-max.) (min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
York 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m - Width:
Large 3 B = 40 mm
16
Bell res English
Installation instructions
Figure 6: Vertical chimney outlet using an existing lined chimney
(Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
(100)
1
4
28
32
18
23
25
26
29
7
5
29
30
10, 11, 12, 13
Y
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y Concentric Concentric
(min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
2.0 - 4.0 m Width: Width:
B = 30 mm B = 65 mm
York Large 3
4.0 - 12.0 m Width: Width:
B = 40 mm B = 80 mm
Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION
POSSIBILITIES
17
Bell res English
Installation instructions
Figure 7: Vertical chimney outlet using a lined chimney with a bend > 45°
(Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Y2
Y1
10, 11, 12, 13
> 45°
X
Y3
32
18
30
29
5
7
29
26
25
23 28
4
1
(100)
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y1 (*) Distance X (*)
Distance Y1 + Y2 + Y3 (*) Concentric Concentric
(min.-max.) (min.-max.) (min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
York 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m - Width:
Large 3 B = 40 mm
18
Bell res English
Installation instructions
Figure 8: Vertical chimney outlet using an existing unsound lined
chimney or when no chimney liners are present
(Flexible Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Y
7
6
8
1832
31
29
30
29
26
29
27
28
29
4
1
(100)
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y Concentric Concentric
(min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
2.0 - 4.0 m Width: Width:
B = 30 mm B = 65 mm
York Large 3
4.0 - 12.0 m Width: Width:
B = 40 mm B = 80 mm
19
Bell res English
Installation instructions
Figure 9: Vertical chimney outlet using an existing unsound lined
chimney or when the chimney is unlined; with a bend >45o
(Flexible Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Y3
Y2
Y1
X
> 45°
6
8
7
31
29
32
18
30
29
26
29
27
28
29
4
1
(100)
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y1 (*) Distance X (*)
Distance Y1 + Y2 + Y3 (*) Concentric Concentric
(min.-max.) (min.-max.) (min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
York 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m - Width:
Large 3 B = 40 mm
20
Bell res English
Installation instructions
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Wall
Termination
Position
(100)
4
28
1
Y
X19
14
10, 11, 13
0.16 m
Appliance: Concentric fl ue connection
Ø100-Ø150 mm or Ø130-Ø200 mm
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Figure 10: Horizontal wall termination
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance: Distance Y Distance X Concentric Concentric
(min.-max.) (min.-max.) connection connection
on appliance is on appliance is
Ø100-Ø150 mm Ø130-Ø200 mm
2.0 - 3.0 m 0 - 0.6 m - -
York Large 3
3.0 - 4.0 m 0 - 1.6 m - -
21
Bell res English
Installation instructions
Figure 11: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Wall
Termination
Position
100
4
128
1
Y
X19
14
110, 111, 113
0.16 m
Appliance: Concentric fl ue connection
Ø130-Ø200 mm
Assemble restriction plate:
Appliance: Distance Y Distance X Concentric connection on
(min.-max.) (min.-max.) appliance is Ø130-Ø200 mm
0.5 - 1.0 m 0 - 0.6 m Width: B = 40 mm
York Large 3
1.0 - 2.0 m 0 - 2.6 m -
Item descriptions:
see 1.6.2
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
22
Bell res English
Installation instructions
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Figure 12: Horizontal wall termination
Appliance: Concentric fl ue connection
Ø130-Ø200 mm
Assemble restriction plate:
Appliance: Distance Y Distance X Concentric connection on
(min.-max.) (min.-max.) appliance is Ø130-Ø200 mm
0.5 - 1.0 m 0 - 1.6 m -
York Large 3
1.0 - 3.0 m 0 - 4.6 m -
Item descriptions:
see 1.6.2
100
4
128
1
Y
X19
114
110, 111, 113
0.25 m
123
Wall
Termination
Position
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
23
Bell res English
Installation instructions
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Figure 13: Horizontal wall termination
Appliance: Concentric fl ue connection
Ø130-Ø200 mm
Assemble restriction plate:
Appliance: Distance Y1 Distance X1 Distance Y2 Distance X2 Concentric connection on
(min.-max.) (min.-max.) (min.-max.) (min.-max.) appliance is Ø130-Ø200 mm
0 - 0.5 m 0 - 0.5 m 0.5 - 1.0 m 0 - 0.6 m -
York 0.5 - 1.0 m 0 - 0.5 m 0 - 0.5 m 0 - 0.6 m -
Large 3
1.0 - 3.0 m 0 - 1.0 m 0.5 - 2.0 m 0 - 0.6 m -
1.0 - 3.0 m 0 - 3.0 m 1.0 - 3.0 m 0 - 0.6 m -
Item descriptions:
see 1.6.2
110, 111, 113
128
4
1
114
14
114
110, 113
110, 111,
113
100
19
0.16 m
Y2
X2
Y1
X1
Wall
Termination
Position
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
24
Bell res English
Installation instructions
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Figure 14: Horizontal wall termination
Item descriptions:
see 1.6.2
4
128
1
Y
X119
114
110, 111, 113
0.25 m
123
Wall
Termination
Position
Appliance: Concentric fl ue connection
Ø130-Ø200 mm
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø130 mm - Ø200 mm
Assemble restriction plate:
Appliance: Distance Y Distance X Concentric connection on
(min.-max.) (min.-max.) appliance is Ø130-Ø200 mm
0 - 0.5 m 0 - 0.6 m -
York Large 3 0.5 - 1.0 m 0 - 3.6 m -
1.0 - 3.0 m 0 - 8.6 m -
25
Bell res English
Installation instructions
AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC
FLUE SYSTEM Ø100 mm - Ø150 mm
1.6.2 Item descriptions for ! gures 4 t/m 14
FIG.
NO.
10
11
12
13
14
DESCRIPTION
Twin-wall balanced ! ue pipe,
L = 500 mm, incl. and
Twin-wall balanced ! ue pipe,
L = 1000 mm, incl. and
Telescopic twin-wall balanced ! ue
pipe, L = min. 325 / max. 440 mm,
incl. and
Adjustable length twin-wall
balanced ! ue pipe,
L = 500 mm, incl. and
Twin-wall balanced ! ue elbow 90°,
incl. and
BELLFIRES
ART. /
ORDER
NO.
302289
302290
302291
302292
302297
Color(*) Application
RVS
antr.
RIGID
FLEX
l
l
l
l
l
l
l
l
l
l
FIG. NO. DESCRIPTION
1 Gas " re; Concentric ! ue connection Ø130/Ø200 mm or Ø100/Ø150 mm
2 -
3 -
4 Restriction plate
(The different sizes restriction plates are supplied with every appliance)
5 Chimney, min. Ø150 mm internal, totally gas tight.
6 Chimney or " reproof sleeving. Min. Ø160 mm internal.
7 Ø100 mm internal ! exible stainless steel gas vent chimney liner AISI 316TI.
8 Ø150 mm internal ! exible stainless steel gas vent chimney liner AISI 316TI.
9 -
26
Bell res English
Installation instructions
FIG.
NO.
15
16
17
18
19
20
21
23
24
DESCRIPTION
Twin-wall balanced ! ue elbow 45°,
incl. and
Vertical (roof) termination kit,
L = 1360 mm (vertical),
incl. , and
Adjustable roof ! ashing.
Roof pitch 20° - 45° (**),
with lead ! ashing
Roof ! ashing for existing chimney
or ! at roof
Horizontal (wall) termination kit,
L = 600 mm (horizontally adjustable)),
incl. , and one set of wall spacer
plates
:
Stainless steel locking band
Ø150 mm, quick-fastening
: Silicone seal Ø150 mm
: Wall strap
Set of ceiling " nishing plates /
Fire stops
BELLFIRES
ART. /
ORDER
NO.
302298
302295
302212
302213
302296
302293
302210
302215
302214
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID
FLEX
27
Bell res English
Installation instructions
FIG.
NO.
25
26
27
28
29
30
31
32
33
DESCRIPTION
Ceiling plate for transition
Ø100 mm / Ø150 mm rigid -
Ø100 mm (! ex.).
Stainless steel adapter piece (100)
from " re to ! exible, Ø100 mm
external (rigid) x Ø107 mm internal
(! ex.).
[appliance - Ø100 mm ! ex.] and
[Ø100 mm rigid - Ø100 mm ! ex.].
Stainless steel adapter piece (150)
" re to ! exible, Ø148 mm external
(rigid) x Ø148 mm internal (! ex.)
[appliance - Ø150 mm ! ex.].
Stainless steel locking band
Ø150 mm.
For adapter 150 [appliance - Ø150
mm (! ex.)], Screw-fastening
Stainless steel screws Ø3.5 mm x
9.5 mm. For securing the ! exible
concentric ! ue. (Minimum 3 screws
per connection)
Hose clamp Ø100 mm.
(Minimum 2 per connection)
Hose clamp Ø150 mm.
(Minimum 2 per connection)
Vertical (roof) termination kit,
L = 610 mm (vertical), incl. and .
For the ! exible ! ue system.
Concentric T-piece with gauging
ori" ce, incl. and
BELLFIRES
ART. /
ORDER
NO.
302189
302278
302279
302217
303776
304041
304042
302307
302301
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID
FLEX
28
Bell res English
Installation instructions
FIG.
NO.
34
35
36
DESCRIPTION
Concentric pipe with gauging
orifi ce, L = 165 mm,
incl. and
90° concentric bend with
inspection panel,
incl. and
Universal wall / fl oor support
Ø150 mm
BELLFIRES
ART. /
ORDER
NO.
302302
302303
321948
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID
FLEX
(*) : Color : RVS : Stainless steel self-colour, polished
antr. : Anthracite colour lacquer, matt
(**) : Adjustable roof fl ashing for a slope > 45° can be supplied on request.
When installing a balanced-fl ue “clo
sed” ga
s fi re in an existing chimney, ens
ure st
ainless
steel fl exible liners (
Ø100 mm or Ø130 mm)
conforming with BS 316 are used to conduct
the spent gases.
29
Bell res English
Installation instructions
AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC
FLUE SYSTEM Ø130 mm - Ø200 mm
FIG
NO.
100
110
111
113
114
115
119
DESCRIPTION
Concentric reduction of
Ø130 / Ø200 mm
Ø100 / Ø150 mm
Twin-wall balanced ! ue pipe,
L= 500 mm, incl. and
Twin-wall balanced ! ue pipe,
L= 1000 mm, incl. and
Adjustable length twin-wall
balanced ! ue pipe,
L= 500 mm, incl. and
Twin-wall balanced ! ue elbow 90°,
incl. and
Twin-wall balanced ! ue elbow 45°,
incl. and
Horizontal (wall) termination kit
,
L= 600 mm (h
orizontally
adjustable), incl. , and one set
of wall spacer plates
BELLFIRES
ART. /
ORDER
NO.
302319
302308
302309
302310
302314
302315
302313
l
l
l
l
l
l
ll
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID
FLEX
30
Bell res English
Installation instructions
FIG.
NO.
120
121
123
124
126
127
128
129
130
131
DESCRIPTION
: Stainless steel locking band
Ø200 mm, quick-fastening
: Silicone seal Ø200 mm
ˆ : Wall strap
Set of ceiling fi nishing plates /
Fire stops
Stainless steel adapter piece (130)
from fi re to fl exible,
Ø130 mm
external (rigid) x Ø137 mm internal
(fl ex.), [appli
ance - Ø130 mm fl ex.]
and [Ø130 mm rigid - Ø130 mm fl ex.]
Stainless steel adapter piece (200)
from fi re to fl exible, Ø198 mm
external (rigid) x Ø198 mm internal
(fl ex.), [appliance - Ø200 mm fl ex.]
Stainless steel locking band Ø200
mm. For adapter 200. [appliance -
Ø200 mm fl ex.]. Screw-fastening
Stainless steel screws Ø3.5 mm x
9.5 mm. For securing the fl exible
concentric fl ue. (Minimum 3 screws
per connection)
Hose clamp Ø130 mm.
(Minimum 2 per connection)
Hose clamp Ø200 mm.
(Minimum 2 per connection)
BELLFIRES
ART. /
ORDER
NO.
302311
302248
302251
302250
302281
302282
302257
303776
304045
304046
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID
FLEX
31
Bell res English
Installation instructions
FIG.
NO.
10
11
12
14
15
DESCRIPTION
Twin-wall balanced ! ue pipe,
L = 250 mm
Twin-wall balanced ! ue pipe,
L = 450 mm
Twin-wall balanced ! ue pipe,
L = 950 mm
Telescopic twin-wall balanced ! ue pipe,
L = min. 390 mm / max. 640 mm
Twin-wall balanced ! ue elbow 90°
Twin-wall balanced ! ue elbow 45°
POUJOULAT
ART. /
ORDER
NO.
37100403
37100404
37100405
37100429
37100441
37100421
AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC
FLUE SYSTEM Ø100 mm - Ø150 mm
32
Bell res English
Installation instructions
FIG.
NO.
16
17
DESCRIPTION
Twin-wall balanced ! ue elbow 30°
Twin-wall balanced ! ue elbow 15°
Vertical (roof) termination kit,
L = 140 mm
Roof ! ashing, suitable for a brick roof,
with a roof pitch of 15°- 30°
Roof ! ashing, suitable for a tiled roof,
with a roof pitch of 15°- 30°
Roof ! ashing, suitable for a brick roof,
with a roof pitch of 30°- 45°
Roof ! ashing, suitable for a tiled roof,
with a roof pitch of 30°- 45°
POUJOULAT
ART. /
ORDER
NO.
37100411
37100401
37100654
45150171
45150170
45150172
45150173
33
Bell res English
Installation instructions
FIG.
NO.
18
19
20
23
24
34
DESCRIPTION
Roof ! ashing for existing chimney
or ! at roof
Horizontal (wall) termination kit
,
L = min. 365 mm / max. 585 mm
Stainless steel locking band Ø150 mm,
quick-fastening
Wall strap, Ø150 mm
Ceiling/wall plate with spacers and
ventilation grooves
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 0°- 10°
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 10°- 30°
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 30°- 40°
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 40°- 50°
Concentric pipe with inspection opening,
L = 250 mm
POUJOULAT
ART. /
ORDER
NO.
45150169
37100610
45150076
45150072
37100442
37100425
37100426
37100427
37100428
37100407
34
Bell res English
Installation instructions
FIG.
NO.
36
36
37
100
101
DESCRIPTION
Roof support, (universal) Ø150 mm
Floor support, (universal) Ø150 mm
Adapter: Bellfi res Ø100-150 mm
Poujoulat PGI Ø100-150 mm
(Appliance 100/150 Poujoulat PGI
100/150)
Adapter: Bellfi res Ø130-200 mm
Poujoulat PGI Ø100-150 mm
(Appliance 130/200 Poujoulat PGI
100/150)
Concentric reduction of
Poujoulat PGI Ø130-200 mm
Poujoulat PGI Ø100-150 mm
POUJOULAT
ART. /
ORDER
NO.
45150165
45150081
37100611
37100614
37100613
35
Bell res English
Installation instructions
AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC
FLUE SYSTEM Ø130 mm - Ø200 mm
FIG.
NO.
110
111
112
114
115
POUJOULAT
ART. /
ORDER
NO.
37130403
37130404
37130405
37130429
37130441
37130421
DESCRIPTION
Twin-wall balanced ! ue pipe,
L = 250 mm
Twin-wall balanced ! ue pipe,
L = 450 mm
Twin-wall balanced ! ue pipe,
L = 950 mm
Telescopic twin-wall balanced ! ue pipe,
L = min. 390 mm / max. 640 mm
Twin-wall balanced ! ue elbow 90°
Twin-wall balanced ! ue elbow 45°
36
Bell res English
Installation instructions
FIG.
NO.
115
119
120
123
124
DESCRIPTION
Twin-wall balanced ! ue elbow 30°
Twin-wall balanced ! ue elbow 15°
Horizontal (wall) termination kit
,
L = min. 425 mm / max. 585 mm
Stainless steel locking band Ø200 mm,
quick-fastening
Wall strap, Ø200 mm
Ceiling/wall plate with spacers and
ventilation grooves
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 0°- 10°
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 10°- 30°
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 30°- 40°
Set of ceiling " nishing plates / Fire stops,
suitable for a roof pitch of 40°- 50°
POUJOULAT
ART. /
ORDER
NO.
37130411
37130401
37130610
45200076
45200072
37130442
37130425
37130426
37130427
37130428
37
Bell res English
Installation instructions
FIG.
NO. DESCRIPTION
Concentric pipe with inspection opening,
L = 250 mm
Roof support, (universal) Ø200 mm
Floor support, (universal) Ø200 mm
Adapter: Bellfi res Ø130-200 mm
Poujoulat PGI Ø130-200 mm
(Appliance 130/200 Poujoulat PGI
130/200)
POUJOULAT
ART. /
ORDER
NO.
37130407
45200165
45200081
37130615
38
Bell res English
Installation instructions
AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC
FLUE SYSTEM Ø100 mm - Ø150 mm
FIG.
NO.
10
11
12
14
15
DESCRIPTION
Adapter for Bellfi res appliances with Ø100-Ø150 mm
concentric connection
Twin-wall balanced fl ue pipe, L = 250 mm
Twin-wall balanced fl ue pipe, L = 500 mm
Twin-wall balanced fl ue pipe, L = 1000 mm
Telescopic twin-wall balanced fl ue pipe,
L = min. 60 / max. 250 mm
Twin-wall balanced fl ue elbow 90°
Twin-wall balanced fl ue elbow 45°
Twin-wall balanced fl ue elbow 30°
ONTOP
ART. /
ORDER
NO.
USA 10
US 25 10
US 50 10
US 100 10
USPP 10
USB 90 10
USB 45 10
USB 30 10
39
Bell res English
Installation instructions
FIG.
NO.
16
16
17
17
18
18
19
DESCRIPTION
Twin-wall balanced ! ue elbow 15°
Vertical (roof) termination kit,
L = 375 mm, incl.
Storm collar Ø150 mm
Adjustable roof ! ashing.
Roof pitch 20° - 45° (**), with lead ! ashing
Roof ! ashing plate for roof pitch 5°- 30°
Roof ! ashing for existing chimney
or ! at roof
Roof ! ashing - Aluminium for existing chimney
or ! at roof
Horizontal (wall) termination kit,
L = 475 mm (horizontally adjustable))
,
incl.
ONTOP
ART. /
ORDER
NO.
USB 15 10
USDVC2 10
USSR 10
USLS 10
USDH 10
USDP 10
USDPAL 10
USDHC5 10
40
Bell res English
Installation instructions
FIG.
NO.
20
21
23
23
24
24
25
25
DESCRIPTION
:
Locking band, quick-fastening
: Cover band, screw-fastening
Wall strap, adjustable
Fitting bracket
Set of ceiling fi nishing plates / Fire stops /
Centring plates
Roof support
Renovation set
Top of renovation set
ONTOP
ART. /
ORDER
NO.
USKB 10
USAB 10
USMB 10
USEB 10
USCP 10
USDQ 10
USSAN 10
USSAN1 10
41
Bell res English
Installation instructions
FIG.
NO.
25
28
34
35
DESCRIPTION
Bottom renovation set
Locking band
, screw-fastening
Concentric pipe with inspection panel,
L = 250 mm
Concentric pipe with gauging orifi ce,
L = 150 mm
90° concentric bend with inspection panel
Rosette smooth Ø150 mm
Wall plate large Ø150 mm,
300 mm
Spacer bracket
ONTOP
ART. /
ORDER
NO.
USSAN2 10
USKBS 10
USI 10
USEM 10
USBI 10
USR 10
USMPG 10
ASAH 10
42
Bell res English
Installation instructions
AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC
FLUE SYSTEM Ø130 mm - Ø200 mm
FIG.
NO.
10
11
12
14
DESCRIPTION
Adapter for Bellfi res appliances with Ø130-Ø200 mm
concentric connection
Twin-wall balanced fl ue pipe, L = 250 mm
Twin-wall balanced fl ue pipe, L = 500 mm
Twin-wall balanced fl ue pipe, L = 1000 mm
Telescopic twin-wall balanced fl ue pipe,
L = min. 60 / max. 250 mm
Twin-wall balanced fl ue elbow 90°
ONTOP
ART. /
ORDER
NO.
USA 13
US 25 13
US 50 13
US 100 13
USPP 13
USB 90 13
FIG.
NO. DESCRIPTION
Concentric reduction of Ø100-Ø150 mm
Ø130-Ø200 mm
ONTOP
ART. /
ORDER
NO.
USVG 10 13
43
Bell res English
Installation instructions
FIG.
NO.
15
16
16
17
17
DESCRIPTION
Twin-wall balanced ! ue elbow 45°
Twin-wall balanced ! ue elbow 30°
Twin-wall balanced ! ue elbow 15°
Vertical (roof) termination kit,
L = 375 mm, incl.
Storm collar Ø150 mm
Adjustable roof ! ashing.
Roof pitch 20° - 45° (**), with lead ! ashing
Roof ! ashing plate for roof pitch 5°- 30°
ONTOP
ART. /
ORDER
NO.
USB 45 13
USB 30 13
USB 15 13
USDVC2 13
USSR 13
USLS 13
USDH 13
44
Bell res English
Installation instructions
FIG.
NO.
18
18
19
20
21
23
23
24
DESCRIPTION
Roof ! ashing for existing chimney
or ! at roof
Roof ! ashing - Aluminium for existing chimney
or ! at roof
Horizontal (wall) termination kit,
L = 475 mm (horizontally adjustable))
,
incl.
:
Locking band, quick-fastening
: Cover band, screw-fastening
Wall strap, adjustable
Fitting bracket
Set of ceiling " nishing plates / Fire stops /
Centring plates
ONTOP
ART. /
ORDER
NO.
USDP 13
USDPAL 13
USDHC4 13
USKB 13
USAB 13
USMB 13
USEB 13
USCP 13
45
Bell res English
Installation instructions
FIG.
NO.
24
25
25
25
28
34
DESCRIPTION
Roof support
Renovation set
Top of renovation set
Bottom renovation set
Locking band
, screw-fastening
Concentric pipe with inspection panel,
L = 250 mm
Concentric pipe with gauging orifi ce,
L = 150 mm
ONTOP
ART. /
ORDER
NO.
USDQ 13
USSAN 13
USSAN1 13
USSAN2 13
USKBS 13
USI 13
USEM 13
46
Bell res English
Installation instructions
FIG.
NO.
35
DESCRIPTION
90° concentric bend with inspection panel
Rosette smooth Ø200 mm
Wall plate large Ø200 mm,
350 mm
Spacer bracket
Concentric reduction of Ø130-Ø200 mm
Ø100-Ø150 mm
ONTOP
ART. /
ORDER
NO.
USBI 13
USR 13
USMPG 13
ASAH 13
USVG 13 10
The room-sealed gas appliances have been approved in combination
with the components of the concentric ! ue systems listed in this
instruction book, according to the European CE norm for gas appliances
and may therefore be used only with these components.
The components of the concentric ! ue system of Bell" res (M&G system),
Poujoulat (PGI system) and Ontop (Metaloterm US system) may
not be used together in one installation.
Check whether the wall or roof termination kit to be used exactly
matches one of those listed in this instruction book.
1.6.3 Gas connection
Operation (gas regulating block (and receiver)) outside the appliance (in the operating
unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.
47
Bell res English
Installation instructions
Figure 15: A clearence of at least 6 cm must be maintained between
the bottom of the appliance and the fl oor.
1.6.4 Operating unit
If the appliance is fi tted with an operating unit comprising gas control block and receiver,
this will be located, once it has been built in, at a maximum of 50 cm from the left or
right hand side of the appliance.
1.6.5 Convection package connections
When fi tting a convection package (= convection casing and convection set (1x or 2x)),
consideration should be given to the openings at approximately 1 meter above the
appliance for the warm air exiting grids.
1.7 POSITIONING THE APPLIANCE
Important: The fi replace is constructed on a suffi ciently solid fl oor that
can bear the weight of the appliance.
Ensure a free space of at least 6 cm between the bottom of
the appliance and the fl oor.
Ensure that the temperature of the fl oor under and in front of
the appliance can never rise above 85°C!
Make use of a temperature protection plate (of nonfl ammable
material) on the fl oor if necessary.
Take care with a fl oor made of a fl ammable material.
Min. 1 cm
48
Bell res English
Installation instructions
Never position the appliance directly against the rear wall,
but always place an nonfl ammable insulation plate, at least
12 mm thick, between the appliance and the rear wall, with
free space on either side of 2 cm. (Total ± 5 cm.)
The rear wall must be made of nonfl ammable material.
Never use combustible materials during the installation.
Ventilate the fi replace, by allowing vents above and
below the fi replace.
During installation of the gas fi re, a clearance of 3 mm
should be maintained on all sides of the appliance to
allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides
may be fi tted with a strip of white, loose insulation wool
(heat-resistant to 1000°C), width 15 cm max. to protect
the wall.
Do not use fi breglass or Rockwool, or any other sort of
insulating material. These emit a pungent odour.
This is considered extremely unpleasant.
They may also cause discolouring of the column.
Flammable materials, such as curtains, should not
be placed in the vicinity of the gas fi re.
Minimum safe distance: 100 cm.
If desired, fi t a convection package to the appliance.
(See chapter 1.1)
The appliance can be easily installed using a set of carrying brackets (accessory).
After installing: remove carrying brackets"
49
Bell res English
Installation instructions
Figure 16: Appliance installed in ventilated chimney breast
Horizontal outlet of the fl ue gas exhaust /combustion air
supply via the wall.
Fitted with the options / accessories:
convection package (= convection casing and 1x convection set)
1x extra convection set
high adjustable feet
1 Inlet opening (appliance) convection air
2 Inlet opening (grate) (chimney breast) convection air
3 Natural convection in the chimney breast
4 Outlet opening (grate) (chimney breast) natural convection air
5
Outlet opening (appliance) convection air / connection convection set (2x or 4x)
6
Outlet opening (grill convection set) (chimney breast) convection air (2x or 4x)
7 -
8 Concentric ! ue connection appliance; Ø130-200 mm for a horizontal wall outlet
9 Horizontal wall outlet
10 Built in operating unit with gas regulating block and receiver

50
Bell res English
Installation instructions
Figure 17: Appliance installed in ventilated chimney breast
Vertical outlet of the fl ue gas exhaust / combustion air
supply via the roof.
Fitted without convection package
1 Inlet opening (appliance) convection air
2 Inlet opening (grate) (chimney breast) convection air
3 Natural convection in the chimney breast
4 Outlet opening (grate) (chimney breast) convection air (2x)
5 Concentric ! ue connection appliance; Ø100-150 mm for a vertical roof outlet
6 Concentric ! ue system; Ø100-150 mm for a vertical roof outlet
7 Built in operating unit with gas regulating block and receiver
51
Bell res English
Installation instructions
When • tting the appliance, it can be levelled with the adjustable feet
.
These adjustable feet can be reached via the openings (4x), after removing the
protective covers, in the corners of the • oor of the combustion chamber.
The • oor of the combustion chamber can be reached after the window and the grill
around the burner have been removed (see chapter 4).
Using an Allenkey (no. 5), the appliance can be adjusted to the required height.
- Position 4 protecting covers. - Protecting cover.
- Adjustable feet seen from the bottom - Adjust height with Allenkey no. 5.
of the appliance.
ƒ
Press the
4 protecting covers back into the • oor.
52
Bell res English
Installation instructions
- 2x Mounting bracket.
Position the gas supply pipe such that it can be easily mounted after installation.
Because the control system is outside the appliance, the gas pipe must lead to where
the operating unit (built in), the gas regulating block (and the receiver) assembly are
tted.
Move the appliance until it is ± 5 cm from the rear wall and ensure it is level. Place the
non• ammable insulation plate (min. 12 mm) between the appliance and rear wall. The
appliance may not be installed against a • ammable rear wall.
Attach the appliance to the rear wall with 2 wedge bolts. Use the adjustable mounting
brackets at the side of the appliance for this.
53
Bell res English
Installation instructions
Figure 18: Operating unit
Frame with
door (white)
Operating unit
1.7.1 Gas connection operating unit
Important: During gas connection, take care not to twist the gas
regulator block. Make sure that both the gas regulator
block and the supply pipes are not subjected to stresses.
The appliance is supplied with a built-in operating unit.
Remove the decorative edging and door of the operating unit.
Fit the separate operating unit, where the gas regulator block and receiver will be
placed, on max. 50 cm from the appliance.
The burner, gas regulator block and receiver have been fully factory assembled.
Disconnect the bracket with the gas regulator block and receiver from the appliance.
Carefully move the bracket with the gas regulator block, receiver, pipes and cables to
the operating unit. Mount the bracket at the bottom of the operating unit.
Important: Take care that no pipes get damaged and no compression ! ttings
come loose when moving the gas regulator block. Prevent twisting
the " exible pipes# Check all compression ! ttings for leaks
afterwards#
Mount the receiver in the top of the operating unit. Check afterwards that all electric
connections are properly connected.
General:
Route all piping and cables from the operating unit to the appliance through an easily
accessible hollow cavity.
During subsequent installation of the operating unit, protect the gas regulator block and
piping against encasement by cement etc.
54
Bell res English
Installation instructions
Gas pipe
“rear burner”
Ø8 mm Flex.
Gas valve
“rear burner”
Gas pipe
“front burner”
Ø8 mm Flex.
Gas supply
connection
Gas regulator block
Thermocouple
Pilot light pipe
Ø4 mm Flex.
Thermocouple
interrupter
Figure 19: Gas regulator block and gas valve: Gas and thermocouple connections
Important : Cement and chalk can damage
the piping and can, in turn,
lead to gas leaks.
Disassembly and assembly of pipes and cables:
If necessary for mounting, all pipe compression fi ttings and cable connectors can be
temporarily disassembled. After mounting, carefully reassemble all pipes and cables.
Check afterwards all compression fi ttings for leaks and that all electric connections are
properly connected.
Important : Screw the thermocouple connection (and thermocouple
interrupter) manually into the gas regulator block. Afterwards,
carefully fasten a half turn with a spanner.
Note : Check that the fl exible burner pipes are correctly connected!
The gas connection of the gas valve “rear burner” must be
connected to the “rear burner”! See Chapter 5. Switching over the
exible burner pipes during assembly can lead to an explosive
ignition. Prevent this at all costs!
55
Bell res English
Installation instructions
Figure 20: Gas regulator block - Front
Inlet
Pressure Tap
Outlet
Pressure Tap
Gas supply
connection
Gas connection for
to the “front burner”
Gas connection for gas valve
to the “rear burner”
Thermocouple
interrupter
connection
Adjustment
Screw
Minimum
Burner pressure
Pilot light
connection
Figure 21: Gas regulator block - Rear
Pilot Gas Adjustment Screw
(Pierce the housing with
a small screwdriver)
Adjustment Screw
Maximum
Burner pressure
Motor-knob
Microswitch8 Wire connecting
cable receiver
56
Bell res English
Installation instructions
Figure 22: Receiver - Top
Figure 23: Receiver - AUX connection - RESET button
Thermocouple
voltage / current
OUT - connection (yellow)
Piezo cable
connection
RESET button
AUX:
Electrical
connection
for gas valve
“rear burner”
TCSW
Thermocouple
voltage / current
IN - connection (red)
6 VDC Adapter
connection
(option)
Connection
8 wire cable
gas regulator block
Connection for
external operating
(option)
RESET button
AUX:
Electrical
connection
for gas valve
“rear burner”
57
Bell res English
Installation instructions
1.7.2 Connecting the concentric fl ue
Assemble the concentric ! ue system according to one of the examples in section 1.6.1,
" gure 4 to 14 inclusive.
Make sure that all connections are completely gas tight.
1.7.3 Building in the appliance
Remove the front of the casing, if applicable. (See Chapter 4: Dismantling / Assembling
of the glass.)
Decide on positions of the vents (grilles above and below the " replace) and, if
applicable, the hot air grids of the convection package.
The brickwork must be built up around the hearth. In connection with the hearth
expanding during burning: there must be at least 3 mm clearance on either side of the
appliance. Do not build up the brickwork farther than the angle irons/brackets (keep in
mind the thickness of any plastering#).
Do not use masking tape on the appliance when installing
and plastering.
Tape can damage the fi nish of the hearth.
Connect up the convection package, if applicable.
The optional mantle iron is intended for supporting the brickwork above the hearth.
The mantle iron must rest on the brickwork on both sides so that upward building is
possible. The brickwork therefore must not rest on the " replace; there must be approx.
3 mm clearance in connection with the weight.
If using other materials, such as stone or heat-resistant plating, you should follow the
supplier’s instructions.
Once the " replace has been " nished, you can now, " t the frame with the small door to
the operating unit.
After installation in a new fi replace and/or applying new cement work, the
appliance cannot be used for at least four weeks.
58
Bell res English
Installation instructions
1.7.4 Checking the gas connection
After connection of the gas supply, check that all connections are completely gas tight
using soapy water or a leak tester.
1.7.5 Positioning the ceramic log set or marble pebbles
The appliance can be supplied with:
Ceramic log set + embers
Marble pebbles white (small, white marble stones)
Marble pebbles grey (small, grey marble stones)
Important: Carefully place the chips of wood/embers/vermiculite granules/
log set or marble pebbles, on and around the main burner
according to the directions in this chapter.
Do not place any chips of wood/embers/vermiculite granules/
log set or marble pebbles against the pilot light burner.
For that reason, the main burner has a protective pilot-light cowl.
Never remove this cowl! Make sure that the pilot fl ame can burn
at all times freely over the main burner. Only in this way is
proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
Make sure that all burner orifi ces remains free at all times!
The burner bed (with chips of wood/embers/vermiculite
granules) and the positioning of the logs or marble pebbles
must not be changed.
Only use those items supplied! These been rigorously
checked and the quantities adapted to the appliance.
Replacement parts, including the ceramic mat are available
from your dealer.
Fitting may only be carried out by a qualifi ed person.
Remove the glass according to the instructions in chapter 4; DISMANTLING /
ASSEMBLING OF THE GLASS.
59
Bell res English
Installation instructions
1.7.5.1 Ceramic log set + chips of wood + embers + vermiculite granules
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Remove the embers carefully from their packaging and spread them evenly over the
burner mat and the grate around the burner.
3 Distribute the vermiculite granules (50 gram) evenly over the burner.
60
Bell res English
Installation instructions
Note ! : Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifi ces.
Embers and vermiculite granules must not be placed next to
the pilot light burner.
Important: make sure that all burner openings remain free !!
Burner orifi ces, which are not open, could lead to a dangerous
situation.
4 Place the logs on the burner:
Appliance Natural gas-burner Propane / Butane-burner
see fi gure: see fi gure:
York Large 3 CF/LF 24 25
Keep the burner orifi ces unblocked """
5 Place the chips of wood around the burner.
61
Bell res English
Installation instructions
Logs:
Log no u Log no v
Log no w Log no x
Log no y Log no z
Log no { Log no |
62
Bell res English
Installation instructions
Keep the burner orifi ces unblocked"
Embers must not be placed next to the pilot light burner
Keep the burner orifi ces unblocked"
Figure 24: Log set York Large 3 CF/LF
Position natural gas burner
Embers must not be placed next to the pilot light burner
Figure 25: Log set York Large 3 CF/LF
Position propane/butane burner
y
z
{
w
x
u
v
y
z
{
w
x
uv
63
Bell res English
Installation instructions
1.7.5.2 Marble pebbles
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Spread the pebbles over the whole burner bed (burner and grid around the burner).
Make sure that the pilot light remains free.
York Large 3 CF/LF : see fi gure 27
Figure 26: Marble pebbles-set natural gas and propane/butane-burner
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot fl ame to the burner
Keep the burner
orifi ces unblocked
64
Bell res English
Installation instructions
Keep the burner orifi ces unblocked"
Figure 27: Marble pebbles York Large 3 CF/LF
Position natural gas and propane/butane burner
Marble pebbles must not be
placed next to the pilot light
burner
Keep the burner
orifi ces unblocked"
Important: Do not place any marble pebbles in front of the pilot light.
Make sure that the pilot light can burn freely over the main
burner.
Keep the burner ori! ces unblocked.
Only this way a proper ignition of the main burner is ensured.
Once the logs / marble pebbles have been positioned, replace the glass in the appliance,
following the instructions in chapter 4: DISMANTLING / ASSEMBLING OF THE
GLASS.
1.7.6 Mounting " ue gas restriction plate
Depending on the length and shape of the concentric # ue system and the chimney
construction, you should, if indicated, fi t a restriction plate with a certain width (B) into
the ceiling of the combustion chamber.
To do this, see the set-up options as listed in fi gure 4 through 14.
65
Bell res English
Installation instructions
Important: Ensure that the correct fl ue gas restriction plate is mounted.
Use of the correct fl ue gas restriction plate will provide
optimum effi ciency, fl ame effect and combustion. Mounting
an incorrect fl ue gas restriction plate can result in damage
to the gas fi re.
Figure 28: Positioning restriction plate
Assembly
restriction
plate
66
Bell res English
Installation instructions
The following restriction plates are supplied:
1.7.7 Checking the appliance following installation
After installation, visually check the gas ! ame. When the " re is ignited, the ! ames
should be short and blue/yellow in colour. These ! ames should gradually increase in
height and become more yellow. When all ! ames are yellow, the gas " re has reached
the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
Concentric ! ue connection appliance
[Ø130 - 200 mm]
[Ø100 - 150 mm]
Restriction plate: Horizontal wall outlet Roof-mounted outlet
Width: - B = 30 mm
Width: B = 40 mm B = 40 mm
Width: B = 50 mm B = 50 mm
Width: B = 65 mm B = 65 mm
Width: B = 80 mm -
67
Bell res English
Installation instructions
2 MAINTENANCE
2.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric
ue system (where possible) and the outlet are cleaned and
inspected annually by a recognised fi tter/gas specialist.
The safe operation of the appliance will thus remain
guaranteed.
Maintenance consists of the following:
Remove fi rst the embers, vermiculite granules, logs set or pebbles from the main
burner and carefully clean these with a soft brush.
Clean and inspect (visually) the main burner, pilot light, combustion chamber,
ue system and combustion air intake. Dust can be removed using a vacuum
cleaner.
Clean the glass on the inside of the appliance with glass spray or ceramic hob
cleaner. This also applies to the black mirror side panels, if the appliance is fi tted
with these.
After cleaning;
Carefully replace the embers, vermiculite granules, logs set or pebbles on and
around the main burner according to the installation directions in this instruction
booklet.
Do not place any embers, vermiculite granules, logs or pebbles against the
pilot light burner. Make sure that the pilot fl ame can burn at all times freely over
the main burner. Only in this way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
Check the gas supply, fl ue system, and combustion air supply route for leaks.
Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
Check the complete concentric fl ue system including the outlet construction.
A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake.
Also check that all connections are secure.
68
Bell res English
Installation instructions
3 FAULTS
3.1 POSSIBLE REASONS
Possible reasons for the gas fi re going out are:
The concentric fl ue system is not installed according to one of the methods detailed
in Paragraph 1.6.
An incorrect “fl ue gas restriction plate” is fi tted.
The pilot light extinguishes if fumes are not exhausted or are insuffi ciently
exhausted.
The pilot light is either dirty or defective.
Insuffi cient gas pressure.
(Internal) leak of the concentric fl ue system.
Thermocouple voltage is too low. This is usually caused by insuffi cient heating of the
thermocouple by the pilot light.
Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
Batteries in receiver or remote control are fl at.
3.2 SAFETY MEASURES IN THE APPLIANCE
3.2.1 Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event
of a gas escape from the main burner.
3.2.2 Over pressure safety system
The appliance is fi tted with a patented safety system, whereby the door will extract any
over-pressure that arises in a controlled way. In this, a spring system briefl y causes the
door to hinge forward a few centimetres. A loud noise can occur.
A safety strip limits the maximum degree to which the door can be tilted.
If an over-pressure situation occurs, the appliance should be thoroughly checked by the
installer.
69
Bell res English
Installation instructions
- York Large 3 - Use the hook supplied (see photo) for
Floating Frame opening the frame and the glass.
Note ! : When loosening the frame and
after it has been loosened, sup-
port it with your hand to prevent
it falling forward !
4 DISMANTLING / ASSEMBLING OF THE GLASS
4.1 YORK LARGE 3 FLOATING FRAME
Dismantling of the glass:
- With the hook, pull the thin, metal
spring strips on the top left and
right from the studs on the frame.
70
Bell res English
Installation instructions
- Detail of the stud (right). - Place paperboard on the chimney
breast, under the frame. This helps
prevent damage.
- Dismantle the safety strip from the frame.
stud (right)
71
Bell res English
Installation instructions
- Frame and glass are now removed from the appliance.
- Carefully tilt the frame and the window - Take hold of the frame and the glass
forwards. clamped together and pull these
Note ! : Frame and window are upwards.
two separate parts !
Assembling of the glass:
The assembly of the glass takes place in reverse order.
Important:
Check whether the frame is properly positioned underneath in the 2 holes of the front.
Check whether the frame is placed in the middle of the front.
Check whether the safety strip is securely fastened to the top of the frame (middle).
The glass (frame) must " t tightly all round to the edge of the combustion chamber.
Check that the spring strips, on the top, remain in their proper place.
72
Bell res English
Installation instructions
4.2 YORK LARGE 3 HIDDEN DOOR
Dismantling of the glass:
- York Large 3 Hidden Door.
- Use the hook to pull the frame at the top forward and hold the frame fi rmly.
- Use the hook supplied for opening the
frame (including glass).
73
Bell res English
Installation instructions
Note ! : When loosening the frame and after it
has been loosened, support it with your
hand to prevent it falling forward !
- Dismantle the safety strip from the frame.
- With the hook, pull the thin, metal spring strips on the top left and right from the studs
on the frame.
74
Bell res English
Installation instructions
- Carefully tilt the frame and the glass forwards
at the top.
Prevent damage by laying paperboard on the
chimney breast, under the frame.
Pull the frame upwards and remove it from
the appliance.
Assembling of the glass:
The assembly of the glass takes place in reverse order.
Important:
Check whether the frame is properly positioned underneath in the 2 holes of the front.
Check whether the frame is placed in the middle of the front.
Check whether the safety strip is securely fastened to the top of the frame.
The glass (frame) must fi t tightly all round to the edge of the combustion chamber.
Check that the spring strips, on the top, remain in their proper place.
75
Bell res English
Installation instructions
5 DIAGRAM ELECTRICITY AND GAS
Gas supply
connection
Thermocouple
Ignition(piezo)cable
2 Wire cable
Motor-
knob
Gas pipe “Rear burner”
GAS
REGULATOR
BLOCK
“red”
“black”
AUX
“red”
“yellow”
Pilot light
“Front burner”
“Rear burner”
Pilot light gas pipe
Thermocouple interruptor
8 Wire
connecting
cable
Gas pipe “Front burner”
Gas valve
“Rear burner”
AC power
adapter
230 VAC
(option)
Button “RESET”
Receiver
(with battery compartment
for 4 AA-batteries)
Connection cable
(option) for
external operating
(i.a. Domotica
systems)
Thermo-electrical
cable TC
Thermo-electrical
cable SW
Double burner: : Perforation pattern “Centre Fire” double burner.
+ : Perforation pattern “Line Fire” double burner.
76
Bell res English
Installation instructions
6 DIMENSIONS
6.1 YORK LARGE 3
6.1.1 YORK LARGE 3 - Hidden Door
77
Bell res English
Installation instructions
6.1.2 YORK LARGE 3 - Floating Frame
78
Bell res English
Installation instructions
6.2 YORK LARGE 3 Fitted with the options: - Convection casing
- High adjustable feet
6.2.1 YORK LARGE 3 - Hidden Door
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the ! oor.
79
Bell res English
Installation instructions
6.2.2 YORK LARGE 3 - Floating Frame
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the ! oor.
80
Bell res English
Installation instructions
6.3 YORK LARGE 3 Hidden Door Plus (+)
6.3.1 YORK LARGE 3 - Hidden Door Plus (+) 7 cm Frame
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the ! oor.
81
Bell res English
Installation instructions
6.3.2 YORK LARGE 3 - Hidden Door Plus (+) 10 cm Frame
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the ! oor.
82
Bell res English
Installation instructions
6.3.3 YORK LARGE 3
Hidden Door Plus (+) 10 cm Frame & Decorative Stone
Fitted with the options: - Convection top plate
- High adjustable feet
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the ! oor.
With this model the remote control receiver and the gas regulating block
are located in the " re and can be accessed via the metal cover, under the
stone. The gas " re does not have a separate operating unit ##
83
Bell res English
Installation instructions
OPERATING UNIT
84
Bell res English
Installation instructions
7 TECHNICAL DETAILS/REGULATIONS
National installation regulations:
UK : Gas safety installation and use regulations 1998 plus all relevant
safety and building regulations concerning ! re installation
Document J: Combustion appliances and fuel storage systems
Model : YORK LARGE 3 CF (Centre Fire)
Gas : NATURAL GAS : BUTANE / PROPANE
Country :
GB; G
reat Britain
/IE;
Ireland :
GB; G
reat Britain
/IE;
Ireland
Product identifi cation no : 0063CM3684 : 0063CM3684
Type of appliance under CE-norm : C11 / C31 / C31S : C11 / C31 / C31S
Category of appliance : I2E+ natural gas G20 : I3B/P butane/propane G30/G31
Nominal heat input : 13.7 kW : Butane (G30) : 11.7 kW
(Gross calorifi c value) Propane (G31) : 10.0 kW
Nominal heat output : 10.5 kW : 7.7 - 9.0 kW
Effi ciency class : 1 (85%) : 1 (85%)
NOx-class : 5 : 5
Gas rate (max.) : 1.28 m3
s/hr. : Butane (G30) : 880 gr/hr.
Propane (G31) : 730 gr/hr.
Supply pressure : 20.0 mbar : Butane (G30) : 37.0 mbar
Propane (G31) : 37.0 mbar
Burner pressure (max.) Hot : 15.0 mbar(*) : 29.0 mbar(*)
Burner pressure (max.) Cold : 14.3 mbar(**) : 29.0 mbar(**)
Burner pressure (min.) : 0.8 mbar(***) : 3.0 mbar(***)
Primary air inlet burner Rear : 1x Ø12.0 mm : 1x Ø20.0+corner mm +
2x Ø5.0 mm
Primary air inlet burner Front : 1x Ø12.0 mm : 1x Ø20.0+corner mm +
2x Ø5.0 mm
Gas regulator block : Mertik GV 60 : Mertik GV 60
(remote control)
Main burner : Centre Fire 694 x 130 mm : Centre Fire 694 x 130 mm
Main burner injector Rear : no 210 (= 1x Ø2.10 mm) : no 110 (= 1x Ø1.10 mm)
Main burner injector Front : no 210 (= 1x Ø2.10 mm) : no 130 (= 1x Ø1.30 mm)
Pilot light burner : SIT 0.145.019 : SIT 0.145.019
Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150)
Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system connection : Ø100 mm - Ø150 mm or : Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm : Ø130 mm - Ø200 mm
85
Bell res English
Installation instructions
Model : YORK LARGE 3 CF (Centre Fire)
Gas : NATURAL GAS : BUTANE / PROPANE
Country :
GB; G
reat Britain
/IE;
Ireland :
GB; G
reat Britain
/IE;
Ireland
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
Weight:
- Basis model : 126 kg : 126 kg
- Including all options : 148 kg : 148 kg
- Convection package : 17 kg : 17 kg
(*) : Both burners at maximum. Appliance is on temperature.
(**) : Both burners at maximum. Appliance is cold.
(***) : Both burners at minimum.
Flue gas exhaust and combustion air supply:
Roof-mounted outlet : Concentric ! ue system Ø100 mm - Ø150 mm. Rigid and/or ! exible.
Horizontal wall outlet : Concentric ! ue system Ø130 mm - Ø200 mm. Rigid.
With wall outlet, depending on the ! ue con" guration; Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm.
Heat changing surface: Entire front of the appliance.
86
Bell res English
Installation instructions
Model : YORK LARGE 3 LF (Line Fire)
Gas : NATURAL GAS : BUTANE / PROPANE
Country :
GB; G
reat Britain
/IE;
Ireland :
GB; G
reat Britain
/IE;
Ireland
Product identifi cation no : 0063CM3684 : 0063CM3684
Type of appliance under CE-norm : C11 / C31 / C31S : C11 / C31 / C31S
Category of appliance : I2H natural gas G20 : I3B/P butane/propane G30/G31
Nominal heat input : 14.0 kW : Butane (G30) : 13.5 kW
(Gross calorifi c value) Propane (G31) : 11.5 kW
Nominal heat output : 10.8 kW : 8.8 - 10.4 kW
Effi ciency class : 1 (85%) : 1 (85%)
NOx-class : 5 : 5
Gas rate (max.) : 1.33 m3
s/hr. : Butane (G30) :
1030 gr/hr.
Propane (G31) : 850 gr/hr.
Supply pressure : 20.0 mbar : Butane (G30) : 37.0 mbar
Propane (G31) : 37.0 mbar
Burner pressure (max.) Hot : 11.4 mbar(*) : 29.0 mbar(*)
Burner pressure (max.) Cold : 10.7 mbar(**) : 29.0 mbar(**)
Burner pressure (min.) : 1.3 mbar(***) : 1.0 mbar(***)
Primary air inlet burner Rear : 1x Ø12.0 mm : 1x Ø20.0+corner mm +
2x Ø5.0 mm
Primary air inlet burner Front : 1x Ø12.0 mm : 1x Ø20.0+corner mm +
2x Ø5.0 mm
Gas regulator block : Mertik GV 60 : Mertik GV 60
(remote control)
Main burner : Line Fire 694x130 mm : Line Fire 694x130 mm
Main burner injector Rear : no 210 (= 1x Ø2.10 mm) : nr. 120 (= 1x Ø1.20 mm)
Main burner injector Front : no 255 (= 1x Ø2.55 mm) : nr. 140 (= 1x Ø1.40 mm)
Pilot light burner : SIT 0.145.019 : SIT 0.145.019
Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150)
Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system connection : Ø100 mm - Ø150 mm or : Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm Ø130 mm - Ø200 mm
87
Bell res English
Installation instructions
Model : YORK LARGE 3 LF (Line Fire)
Gas : NATURAL GAS : BUTANE / PROPANE
Country :
GB; G
reat Britain
/IE;
Ireland :
GB; G
reat Britain
/IE;
Ireland
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
Weight:
- Basis model : 126 kg : 126 kg
- Including all options : 148 kg : 148 kg
- Convection package : 17 kg : 17 kg
(*) : Both burners at maximum. Appliance is on temperature.
(**) : Both burners at maximum. Appliance is cold.
(***) : Both burners at minimum.
Flue gas exhaust and combustion air supply:
Roof-mounted outlet : Concentric ! ue system Ø100 mm - Ø150 mm. Rigid and/or ! exible.
Horizontal wall outlet : Concentric ! ue system Ø130 mm - Ø200 mm. Rigid.
With wall outlet, depending on the ! ue con" guration; Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm.
Heat changing surface: Entire front of the appliance.
88
Bell res English
Installation instructions
8 REPLACEMENT PARTS LIST
When requesting service or ordering replacement parts, please quote the model type
and serial number. All parts listed in this manual may be ordered from a Bellfi res dealer.
No Article no Description
1 335116 Main burner “Centre Fire” 694 x 130 mm
Natural gas G20 / Butane/Propane G30/G31
G20: 1x Ø12.0 mm front + 1x Ø12.0 mm rear
G30/G31: 1x Ø20.0+corner mm + 2x Ø5.0 mm front and
1x Ø20.0+corner mm + 2x Ø5.0 mm rear
2 335112 Burner mat L = 694 mm “Centre Fire”
3 334876 Main burner injector Natural gas; Front: no 210 (1x Ø2.10 mm)
4 334876 Main burner injector Natural gas; Rear: no 210 (1x Ø2.10 mm)
5 301928 Main burner injector Butane/Propane; Front: no 130 (1x Ø1.30 mm)
6 334992 Main burner injector Butane/Propane; Rear: no 110 (1x Ø1.10 mm)
7 335117 Main burner “Line Fire” 694 x 130 mm
Natural gas G20 / Butane/Propane G30/G31
G20: 1x Ø12.0 mm front + 1x Ø12.0 mm rear
G30/G31: 1x Ø20.0+corner mm + 2x Ø5.0 mm front and
1x Ø20.0+corner mm + 2x Ø5.0 mm rear
8 335113 Burner mat L = 694 mm “Line Fire”
9 301909 Main burner injector Natural gas; Front: no 255 (1x Ø2.55 mm)
10 334876 Main burner injector Natural gas; Rear: no 210 (1x Ø2.10 mm)
11 334878 Main burner injector Butane/Propane; Front: no 140 (1x Ø1.40 mm)
12 334874 Main burner injector Butane/Propane; Rear: no 120 (1x Ø1.20 mm)
13 333597 Gas regulator block; GV 60 (M10 Thermocouple connection)
14 302122 3/8” male x Ø12 Compression fi tting
15 302084 Nut Ø8 mm for burner supply GV 60 for “front burner”
16 302089 Olive Ø8 mm for burner supply GV 60 for “front burner”
17 333607 Gas valve “rear burner”
18 333608 Adapter 3/8”bsp x 3/8”+ O-ring
19 333610 Nut Ø8 mm for gas valve “rear burner”
20 333611 Olive Ø8 mm for gas valve “rear burner”
21 302086 Cut-off nipple Ø4 mm GV 60
22 333601 Cable (sw): Receiver - Thermocouple interrupter, L = 500 mm
23 333602 Cable (tc): Receiver - Thermocouple interrupter, L = 500 mm
24 333598
Hand-held transmitter: Display screen: Temperature and two programmes
25 333599 Cover battery compartment hand-held transmitter - with imprint:
Operating double burner
26 333600 Receiver GV 60 - EU
27 302068 8 Wire connecting cable Gas regulator block - Receiver, L = 500 mm
28 302421 Piezo ignition cable, 2x 2.8 x 0.8 mm, L = 1500 mm
89
Bell res English
Installation instructions
No Article no Description
29 321926 Thermocouple M10 - 1500 mm
30 333604 Thermocouple interrupter M10
31 310908 Pilot light set outer casing, Double ! ame
32 310909 Packing pilot light set outer casing
33 310910 Pilot light injector; Natural gas; no 36
34 310912 Pilot light injector; Butane/Propane; no 23
35 310907 Piezo electrode for pilot light, 2.8 x 0.5 mm
36 302062 Nut piezo electrode
37 319842 Nut thermocouple
38 332552 Pilot light olive; Ø4 mm, steel
39 332553 Pilot light nut; Ø4 mm, steel
40 322552 Pilot light pipe; Ø4 mm, L = 1500 mm, Flexible, Stainless steel
41 325750 Burner pipe; Ø8 mm, L = 1500 mm, Flexible, Stainless steel - 10 kW+,
“front burner”
42 325750 Burner pipe; Ø8 mm, L = 1500 mm, Flexible, Stainless steel - 10 kW+,
“rear burner”
43 326055 Nut; Ø8 mm, compression elbow main burner
44 326054 Olive; Ø8 mm, compression elbow main burner
45 331294 Glass York Large 3 Hidden Door (990 x 642 x 4 mm)
46 331293 Glass York Large 3 Floating Frame (982 x 648 x 4 mm)
47 301669 Tube ceramic glue
48 301593 Black " bre glass tape 15 x 3 mm, adhesive
49 319664 Black " bre glass tape 30 x 2 mm, adhesive
50 311006 Black " bre glass tape 20 x 2 mm, adhesive
51 301617 Black " bre glass cord Ø10 mm
90
Bell res English
Installation instructions
Logs - Chips of wood - Embers - Vermiculite granules - Marble pebbles
Appliance Log set
Marble pebbles
Marble pebbles
set (white) set (grey)
Set Log no
Art. no:
I 332585
York Large 3
1
331357
1x
2
331358
1x
3
331359
1x
4
331360
1x
6
331362
1x
7
331363
1x
8
331364
-
5
331361
1x
3 pieces
xxxxxx
1x
Bag: 125 gr.
301863
3x
Bag: 50 gr.
332583
1x
Bag: 2.5 kg.
310937
3x
Bag: 2.5 kg.
325758
3x
Chips of Embers with Vermiculite no 4
wood set Glow-effect black
Anthracite ltered
91
Bell res English
Installation instructions
9 DISPOSING OF PACKAGING AND APPLIANCE
The appliance comes in recyclable packaging.
This can include:
Cardboard
Wood
Plastic
Paper
Such materials must be disposed of responsibly, in line with local regulations.
Batteries should be disposed of as chemical waste. Batteries must be disposed of
responsibly, in line with local regulations.
The authorities or fi tter can provide you with information on responsible disposal of
obsolete appliances.
02 - 291123 - 335743
Your Bell• res dealer
90

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bellfires YORK LARGE 3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bellfires YORK LARGE 3 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.93 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Bellfires YORK LARGE 3

Bellfires YORK LARGE 3 Installatiehandleiding - Nederlands - 88 pagina's

Bellfires YORK LARGE 3 Gebruiksaanwijzing - Nederlands - 28 pagina's

Bellfires YORK LARGE 3 Installatiehandleiding - Deutsch - 112 pagina's

Bellfires YORK LARGE 3 Gebruiksaanwijzing - Deutsch - 28 pagina's

Bellfires YORK LARGE 3 Gebruiksaanwijzing - English - 28 pagina's

Bellfires YORK LARGE 3 Gebruiksaanwijzing - Français - 28 pagina's

Bellfires YORK LARGE 3 Installatiehandleiding - Français - 92 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info