67
Bellfi res English
Installation instructions
2 MAINTENANCE
2.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric
fl ue system (where possible) and the outlet are cleaned and
inspected annually by a recognised fi tter/gas specialist.
The safe operation of the appliance will thus remain
guaranteed.
Maintenance consists of the following:
• Remove fi rst the embers, vermiculite granules, logs set or pebbles from the main
burner and carefully clean these with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber,
fl ue system and combustion air intake. Dust can be removed using a vacuum
cleaner.
• Clean the glass on the inside of the appliance with glass spray or ceramic hob
cleaner. This also applies to the black mirror side panels, if the appliance is fi tted
with these.
• After cleaning;
Carefully replace the embers, vermiculite granules, logs set or pebbles on and
around the main burner according to the installation directions in this instruction
booklet.
Do not place any embers, vermiculite granules, logs or pebbles against the
pilot light burner. Make sure that the pilot fl ame can burn at all times freely over
the main burner. Only in this way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, fl ue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check the complete concentric fl ue system including the outlet construction.
A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake.
Also check that all connections are secure.