Preparation manual
Box Gas Panorama 73/52 MF
Serial number:
Production date:
©
© Barbas Bellfires BV
This document or parts thereof may not be reproduced, stored in a retrieval system, or transmitted,
in any form or by any means, electronic, mechanical, photocopying, recording, nor otherwise,
without the prior written permission of Barbas Bellfires BV. This document could contain technical
inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document
from time to time in the contents thereof.
Contact information
Barbas Bellfires BV
Hallenstraat 17, 5531 AB Bladel, The Netherlands
Phone: +31 49 733 9200
E-mail: info@bellfires.com
Introduction
2
Box Gas Panorama 73/52
C
Contents
1 About this document................................................................................ 4
1.1 How to work with this document.................................................................................................. 4
1.2 Warnings and cautions used in this document............................................................................ 4
1.3 Related documentation................................................................................................................4
2 Overview of the concentric flue system................................................... 5
3 Safety.......................................................................................................6
3.1 Safety instructions for installation................................................................................................ 6
4 Requirements...........................................................................................7
4.1 Requirements on the location...................................................................................................... 7
4.2 Other requirements......................................................................................................................7
4.3 Requirements on the outlet..........................................................................................................7
4.3.1 Requirements on the roof outlet........................................................................................7
4.3.2 Requirements on the wall outlet........................................................................................8
4.4 Requirements on the concentric flue system...............................................................................9
4.4.1 Possibilities for a concentric flue system with a roof outlet............................................. 10
4.4.2 Possibilities for a concentric flue system with a wall outlet............................................. 16
5 Technical specification...........................................................................17
5.1 Dimensions Box Gas Panorama 73/52......................................................................................17
5.2 Dimensions Box Gas Panorama 73/52 with Storage module ...................................................18
5.3 Dimensions Box Gas Panorama 73/52 with Support frame ......................................................19
5.4 Dimensions of the restriction plate.............................................................................................20
6 Available components for the concentric flue system............................ 21
6.1 Appliance part list.......................................................................................................................21
6.2 Bellfires - Muelink & Grol system Ø100 - Ø150......................................................................... 22
6.3 Poujoulat - DUOGAS system Ø100 - Ø150...............................................................................26
6.4 Ontop - Metaloterm US system Ø100 - Ø150............................................................................29
6.5 Jeremias/STB - H-Twin system Ø100 - Ø150............................................................................33
6.6 Jeremias - TWIN-GAS system Ø100 - Ø150.............................................................................37
Contents
Box Gas Panorama 73/52
3
1
1About this document
This document shows the necessary information to do these tasks on the Box Gas
Panorama 73/52 MF:
Preparation for installation
This document refers to the Box Gas Panorama 73/52 MF as 'the appliance'. This
document is an essential part of your appliance. Read it carefully before you do work on
the appliance. Keep it in a safe place.
The original instructions of the document are in English. All other language versions of
the document are translations of the original instructions. It is not always possible to
provide a detailed illustration of every single item of the equipment. The illustrations in
this document show a typical setup. The illustrations are for instructional use only.
1.1 How to work with this document
1. Make yourself familiar with the structure and content of the document.
2. Read the safety chapter in detail.
3. Make sure that you understand all the instructions.
4. Do the procedures completely and in the given sequence.
1.2 Warnings and cautions used in this document
Warning
If you do not obey these instructions, there is a risk that can cause personal injury or
death.
Caution
If you do not obey these instructions, there is a risk of damage to the equipment or to
property.
Note
A note shows more information.
Symbol Description
Visual sign that there is a hazard
Visual sign that there is a notice
1.3 Related documentation
Preparation manual
Installation and maintenance manual
User manual
About this document
4
Box Gas Panorama 73/52
2
2Overview of the concentric flue system
The concentric flue system provides the appliance with combustion air and removes the
flue gases from the appliance. The concentric flue system is made of these items:
Item Description
Concentric flue The concentric flue is a pipe with an inner pipe. The in-
ner pipe is used as flue gas channel and the space be-
tween the inner pipe and the outer pipe is used as
combustion air channel
Flue gas channel The flue gases from the appliance flow through the
channel to the outlet by a natural draft
Combustion air channel Supplies the appliance with fresh air from the outlet
through the channel
Outlet/terminal Entry for the combustion air channel and exit for the
flue gas channel
Overview of the concentric flue system
Box Gas Panorama 73/52
5
3
3Safety
3.1 Safety instructions for installation
Caution:
The appliance must be installed as a 'room sealed system' appliance by a
certified and registered gas installation engineer in accordance with the
supplied installation instructions, and nationally and locally applicable
regulations.
If you have any questions regarding the installation, consult your local gas
company.
Only use items in the installation that are specified in this manual and the
related documents.
Only use the following brands for the installation of the concentric flue
system:
Manufacturer system
Bellfires Muelink & Grol system
Poujoulat DUOGAS system
Ontop Metaloterm US system
Jeremias/STB (STB = Schoorsteen
Techniek Brummen NL)
H-Twin system
Jeremias TWIN-GAS system
Do not use a combination of parts from different brands for the installation
of the concentric flue system.
Before beginning the installation, check that the details on the rating plate
correspond to the gas type and supply pressure to which the appliance will
be connected.
Safety
6
Box Gas Panorama 73/52
4
4Requirements
4.1 Requirements on the location
The floor must be sufficiently strong and stable, because of the weight of the
appliance.
Make sure that you keep the minimum safety distances of the appliance to flammable
and nonflammable materials. Refer to the installation and maintenance manual.
Make sure the wall can support the weight of an appliance when attached to the wall.
Situate the appliance in such a way that the concentric flue outlet connection is
precisely in line with the concentric flue pipe to the ceiling or wall.
If the fire burns in the appliance, make sure that the wall temperatures, and floor
temperatures below and in front of the appliance, cannot be higher than 85 °C .
Make sure that the room where the appliance is installed is properly ventilated.
4.2 Other requirements
The gas supply connection is located at the rear of the appliance for an easy
connection to all directions.
Only use gas piping of at least 1/2" and a shut-off valve to connect the gas supply to
the gas connection of the appliance.
Make sure that there is a wall socket with earth connection nearby the appliance. The
socket must be accessible at all times. The powercable (+ 0.5 m) is coming from the
rear of the appliance.
If the wall of floor is made of flammable material, take correct safety measures. Refer
to the installation and maintenance manual.
If the concentric flue system is installed in a chimney that is used for wood or coal fire,
clean the chimney.
4.3 Requirements on the outlet
4.3.1 Requirements on the roof outlet
Make sure that the outlet is installed at least 0.5 meter from the edge of the roof.
Note:
All the minimum distances are guidelines. Consult your national and local
directives for the exact minimum distances.
Location of any of the items(*) Minimum distance between the items
and the roof outlet
At the same roof as the outlet 3 m
At a different roof as the outlet 1 m
At a lower positioned wall than the outlet 1 m
At a higher sloping surface than the outlet 3 m
(*) Items:
A ventilation opening that services an occupied room, a toilet or a bathroom.
A combustibion air supply, if the supply flows through an occupied room.
A window that can be opened that services an occupied room, a toilet or a bathroom.
Requirements
Box Gas Panorama 73/52
7
4
4.3.2 Requirements on the wall outlet
Make sure that the outlet is installed at least 0.5 meter from:
The corner of a building
the edge of the roof
The roof overhang and rain gutter
Balconies etc. unless the exhaust construction extends to at least the face of the
protruding section
Note:
All the minimum distances are guidelines. Consult your national and local
directives for the exact minimum distances.
If the outlet is installed horizontally in less than 0.5 m and vertically in less than 2 m from
a public area, install an effective protector. Make sure that the mesh size of the guard
does not affect the operation of the appliance.
If the height of the outlet is less than 3 meter from the floor, the distance between the
outlet and a garden or a terrace must be at least 2 meter.
Location of any of the items(*) Minimum distance between the items
and the wall outlet
On a wall where the item services a living space other
than that of the owner of the fireplace.
Do not install the wall outlet under an
item.
On a wall (**)
Below the item: 2 m
Above the item: 0.75 m
Left or right of the outlet: 0.75 m
within 1 meter of the roof overhang 2 m
Under a balcony, walkway, etc. 2 meter from the underside of the bal-
cony or walkway
Under a balcony, walkway, etc. if the outlet extends to the
front 2 m
A facing wall less than 2 meters from the outlet. Apply the minimum distance for items
on a wall.
(*) Items:
A ventilation opening that services an occupied room, a toilet or a bathroom.
A combustion air supply, if the supply flows through an occupied room.
A window that can be opened that services an occupied room, a toilet or a bathroom.
(**) If an obstruction protrudes at least 0.5 meter between the item and the outlet and the
obstruction has a lenght of at least the recommended minimum distance, ignore the
recommended minimum distance.
Requirements
8
Box Gas Panorama 73/52
4
4.4 Requirements on the concentric flue system
Caution:
Make sure that no flammable materials are located close to the flue
system. The outer walls of the flue system can be 150 °C.
Make sure that the part of the concentric flue system, which goes up from
the ceiling, is in a casing.
Make sure that the casing is made of heat resistant material.
Make sure that air can flow in the casing. Use grates near the floor and
near the ceiling. Do this for every floor where the casing is located.
Do not insulate the concentric flue.
The parts that are required for the installation of the concentric flue system are numbered
in the illustrations and refer to the part list in
6
.
Use the universal wall/floor support (number 36 in the part list) to attach the concentric
flue system to the casing and/or the floor.
Floor support Wall support
Install a concentric flue system as described in this section.
Some configurations of the concentric flue system require the installation of a flue
restriction plate. Different sizes of the flue restriction plate are delivered with the
appliance. Refer to the Installation and maintenance manual.
Requirements
Box Gas Panorama 73/52
9
4
4.4.1 Possibilities for a concentric flue system with a roof outlet
Rigid concentric flue systems
4,28,(100)
1
10/11/12/13
23
24
17
16
24
18
16
Y
Y
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance is
Ø100-Ø150 mm
2.0 - 4.0 m 30 mm
4.0 - 12.0 m 40 mm
Requirements
10
Box Gas Panorama 73/52
4,28,(100)
1
10/11/12/13
14,15
17
16
24
23
23
Y1
X
Y2
Y1
(min. - max.)
X
(min. - max.)
Y1 + Y2
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance is
Ø100-Ø150 mm
1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m -
Caution:
Make sure that Y1 + Y2 is at least 2 times larger than X.
Requirements
Box Gas Panorama 73/52
11
F
Flexible concentric flue systems
4,28,(100)
1
30
32
29
5
7
26
29
23
25
18
10/11/12/13
Y
Y
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance is
Ø100-Ø150 mm
2.0 - 4.0 m 30 mm
4.0 - 12.0 m 40 mm
Roof outlet using an flexible Ø100 mm liner in an existing lined chimney.
Requirements
12
Box Gas Panorama 73/52
4,28,(100)
1
30
32
29
5
7
26
23
25
29
≥45°
18
10/11/12/13
Y3
Y1
Y2
X
Y
Y1
(min. - max.)
X
(min. - max.)
Y1 + Y2 + Y3
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance is
Ø100-Ø150 mm
1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m -
Caution:
Make sure that Y1 + Y2 + Y3 is at least 2 times larger than X.
Roof outlet using an flexible Ø100 mm liner in an existing lined chimney.
Requirements
Box Gas Panorama 73/52
13
4,28,(100)
1
31
30
32
29
6
8
7
26,29
27,28,29
18
29
Y
Y
Y
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance is
Ø100-Ø150 mm
2.0 - 4.0 m 30 mm
4.0 - 12.0 m 40 mm
Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing
unsound lined chimney.
Requirements
14
Box Gas Panorama 73/52
4,28,(100)
1
30
31
32
29
6
7
8
26,29
27,28,29
≥45°
18
29
Y3
Y1
Y2
X
Y
Y1
(min. - max.)
X
(min. - max.)
Y1 + Y2 + Y3
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance is
Ø100-Ø150 mm
1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m -
Caution:
Make sure that Y1 + Y2 + Y3 is at least 2 times larger than X.
Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing
unsound lined chimney.
Requirements
Box Gas Panorama 73/52
15
4
4.4.2 Possibilities for a concentric flue system with a wall outlet
Install the wall outlet in the correct position as shown in the figure. The centre of the inner
pipe must be positioned above the centre of the outer pipe.
Rigid concentric flue systems
19
1
10/11/12/13
4,28,(100)
14
Y
0.16 m
X
Y
(min. - max.)
X
(min. - max.)
Flue gas restriction plate
width
Concentric connection on
the appliance is Ø100-
Ø150 mm
1.0 - 2.0 m 0 - 5.0 m -
Requirements
16
Box Gas Panorama 73/52
5
5Technical specification
5.1 Dimensions Box Gas Panorama 73/52
Technical specification
Box Gas Panorama 73/52
17
5
5.2 Dimensions Box Gas Panorama 73/52 with Storage module
Technical specification
18
Box Gas Panorama 73/52
5
5.3 Dimensions Box Gas Panorama 73/52 with Support frame
Technical specification
Box Gas Panorama 73/52
19
5
5.4 Dimensions of the restriction plate
Width of the delivered flue restriction plates in mm
Concentric flue connection Ø100 - Ø150
Roof-mounted outlet
30
40
50
65
Technical specification
20
Box Gas Panorama 73/52
6
6Available components for the concentric flue
system
Caution:
Observe the installation instructions that are supplied with the components of
the concentric flue system.
The gas fire, in combination with the concentric flue system [Ø100 mm - Ø150 mm] (rigid
and/or flexible) for the brand types mentioned below, has been approved in accordance
with the European CE-norm for gas appliances and may therefore be used only with
these systems.
Table 1: Approved brands
Manufacturer system
Bellfires Muelink & Grol system
Poujoulat DUOGAS system
Ontop Metaloterm US system
Jeremias/STB (STB = Schoorsteen Techniek
Brummen NL)
H-Twin system
Jeremias TWIN-GAS system
The permitted components for these systems are listed in this chapter. The guarantee on
the appliance lapses if it is installed, fully or partially, with other components or a different
flue system. The concentric flue [Ø100 mm - Ø150 mm] systems can be used with either
a newly-built or existing chimney.
Make sure that the wall or roof termination kit that is used for the installation of the
concentric flue system is also listed in the available parts list.
6.1 Appliance part list
Fig No. Description
1 Gas fire; Concentric flue connection Ø100/Ø150 mm.
2-
3-
4Restriction plate (The different sizes restriction plates are supplied with every appli-
ance).
5 Chimney, min. Ø150 mm internal, totally gas tight.
6 Chimney or fireproof sleeving. min. Ø160 mm internal.
7 Ø100 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
8 Ø150 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
9-
Available components for the concentric flue
system
Box Gas Panorama 73/52
21
6
6.2 Bellfires - Muelink & Grol system Ø100 - Ø150
Fig.
NO.
Bellfires
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
10 302289 Twin-wall balanced flue pipe.
L= 500 mm. ●●
11 302290 Twin-wall balanced flue pipe.
L= 1000 mm. ●●
12 302291
Telescopic twin-wall balanced
flue pipe, L= min. 325 / max.
440 mm.
●●
13 302292
Adjustable length twin-wall
balanced flue pipe, L= 500
mm.
●●
14 302297 Twin-wall balanced flue el-
bow 90°. ●●
Available components for the concentric flue
system
22
Box Gas Panorama 73/52
F
Fig.
NO.
Bellfires
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
15 302298 Twin-wall balanced flue el-
bow 45°. ●●
16 302295 Vertical (roof) termination kit,
L= 1360 mm. ●●●●
17 302212
Adjustable roof flashing. Roof
pitch 20° - 45° (**), with lead
flashing.
●●
18 302213 Roof flashing for existing
chimney or flat roof. ●●
19 302296
Horizontal (wall) termination
kit, L= 600 mm (adjustable),
including a set of wall spacer
plates.
●●●●
20 302293 Stainless steel locking band
Ø150 mm, quick-fastening. ●●
21 302210 Silicone seal Ø150 mm.
23 302215 Wall strap.
24 302214 Set of ceiling finishing plates /
Fire stops. ●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
23
F
Fig.
NO.
Bellfires
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
25 302189
Ceiling plate for transition
Ø100 mm / Ø150 mm rigid -
Ø100 mm (flex.).
●●
26 302278
Stainless steel adapter piece
(100) from fire to fl exible,
Ø100 mm external (rigid) x
Ø107 mm internal (flex.). [ap-
pliance - Ø100 mm flex.] and
[Ø100 mm rigid - Ø100 mm
flex.].
●●
27 302279
Stainless steel adapter piece
(150) fire to fl exible, Ø148
mm external (rigid) x Ø148
mm internal (flex.) [appliance
- Ø150 mm flex.].
●●
28 302217
Stainless steel locking band
Ø150 mm. For adapter 150
[appliance - Ø150 mm (flex.)],
Screw-fastening.
●●
29 303776
Stainless steel screws Ø3.5
mm x 9.5 mm. For securing
the flexible concentric flue.
(Minimum 3 screws per con-
nection).
●●
30 304041 Hose clamp Ø100 mm. (Mini-
mum 2 per connection). ●●
31 304042 Hose clamp Ø150 mm. (Mini-
mum 2 per connection) ●●
Available components for the concentric flue
system
24
Box Gas Panorama 73/52
F
Fig.
NO.
Bellfires
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
32 302307
Vertical (roof) termination kit,
L = 610 mm. Suitable for a
flexible flue system.
●●●●
33 302301 Concentric T-piece with
gauging orifice. ●●
34 302302 Concentric pipe with gauging
orifice, L = 165 mm. ●●
35 302303 90° concentric bend with in-
spection panel. ●●
36 321948 Universal wall / floor support
Ø150 mm ●●
(*)Color
rvs : Stainless steel self-color, polished
antr. : Anthacite color lacquer, matt
(**) Adjustable roof flashing for a slope > 45° can be supplied on request.
When installing a balanced-flue “closed” gas fire in an existing chimney, ensure stainless
steel flexible liners (Ø100 mm or Ø130 mm) conforming with BS 316 are used to conduct
the spent gases.
Available components for the concentric flue
system
Box Gas Panorama 73/52
25
6
6.3 Poujoulat - DUOGAS system Ø100 - Ø150
Fig.
NO.
Poujoulat
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
34100403
Twin-wall balanced flue pipe,
L= 250 mm.
10 34100404 Twin-wall balanced flue pipe.
L= 450 mm. ●●
11 34100405 Twin-wall balanced flue pipe.
L= 950 mm. ●●
12 34100429
Telescopic twin-wall balanced
flue pipe, L= min. 390 / max.
640 mm.
●●
14 34100441 Twin-wall balanced flue el-
bow 90°. ●●
15 34100421 Twin-wall balanced flue el-
bow 45°. ●●
34100411 Twin-wall balanced flue el-
bow 30°. ●●
34100401 Twin-wall balanced flue el-
bow 15°. ●●
Available components for the concentric flue
system
26
Box Gas Panorama 73/52
F
Fig.
NO.
Poujoulat
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
16 34100654 Vertical (roof) termination kit,
L= 140 mm . ●●
17 45150171
Roof flashing, suitable for a
brick roof, with a roof pitch of
15°- 30°.
●●
17 45150170
Roof flashing, suitable for a
tiled roof, with a roof pitch of
15°- 30°.
●●
17 45150172
Roof flashing, suitable for a
brick roof, with a roof pitch of
30°- 45°.
●●
17 45150173
Roof flashing, suitable for a
tiled roof, with a roof pitch of
30°- 45°.
●●
18 45150169 Roof flashing for existing
chimney or flat roof. ●●
19 34100610
Horizontal (wall) termination
kit, L= min. 365 mm / max.
585 mm.
●●
20 45150076 Stainless steel locking band
Ø150 mm, quick-fastening. ●●
23 45150072 Wall strap, Ø150 mm. ●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
27
F
Fig.
NO.
Poujoulat
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
24 37100442
Ceiling/wall plate with
spacers and ventilation
grooves.
●●
24 37100425
Set of ceiling finishing plates /
Fire stops, suitable for a roof
pitch of 0°- 10°.
●●
24 37100426
Set of ceiling finishing plates /
Fire stops, suitable for a roof
pitch of 10°- 30°.
●●
24 37100427
Set of ceiling finishing plates /
Fire stops, suitable for a roof
pitch of 30°- 40°.
●●
24 37100428
Set of ceiling finishing plates /
Fire stops, suitable for a roof
pitch of 40°- 50°.
●●
34 34100407 Concentric pipe with inspec-
tion opening, L= 250 mm. ●●
36 45150165 Roof support, (universal)
Ø150 mm. ●●
36 45150081 Floor support, (universal)
Ø150 mm. ●●
37 34100611
Adapter: Bellfires Ø100-150
mm → Poujoulat DUOGAS
Ø100-150 mm (Appliance
100/150 → Poujoulat DUO-
GAS 100/150)
●●
100 34100614
Adapter: Bellfi res Ø130-200
mm → Poujoulat DUOGAS
Ø100-150 mm (Appliance
130/200 → Poujoulat DUO-
GAS 100/150)
●●
101 34100613
Concentric reduction of Pou-
joulat DUOGAS Ø130-200
mm → Poujoulat DUOGAS
Ø100-150 mm
●●
Available components for the concentric flue
system
28
Box Gas Panorama 73/52
6
6.4 Ontop - Metaloterm US system Ø100 - Ø150
Fig.
NO.
Ontop Art./
ORDER
NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
USA 10
Adapter for Bellfires applian-
ces with Ø100-Ø150 mm
concentric connection.
●●
US 25 10 Twin-wall balanced flue pipe,
L = 250 mm. ●●
10 US 50 10 Twin-wall balanced flue pipe.
L= 500 mm. ●●
11 US 100 10 Twin-wall balanced flue pipe.
L= 1000 mm. ●●
12 USPP 10
Telescopic twin-wall balanced
flue pipe, L= min. 60 / max.
250 mm.
●●
14 USB 90 10 Twin-wall balanced flue el-
bow 90°. ●●
15 USB 45 10 Twin-wall balanced flue el-
bow 45°. ●●
15 USB 30 10 Twin-wall balanced flue el-
bow 30°. ●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
29
F
Fig.
NO.
Ontop Art./
ORDER
NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
15 USB 15 10 Twin-wall balanced flue el-
bow 15°. ●●
16 USDVC2 10 Vertical (roof) termination kit,
L= 375 mm. ●●
16 USSR 10 Storm collar Ø150 mm. ●●
17 USLS 10
Adjustable roof flashing. Roof
pitch 20° - 45°, with lead
flashing.
●●
17 USDH 10 Roof flashing plate for roof
pitch 5°- 30°. ●●
18 USDP 10 Roof flashing for existing
chimney or flat roof. ●●
18 USDPAL 10
Roof flashing - Aluminium -
For existing chimney or flat
roof.
●●
19 USDHC5 10 Horizontal (wall) termination
kit, L= 475 mm (adjustable). ●●
20 USKB 10 Locking band, quick-fasten-
ing. ●●
Available components for the concentric flue
system
30
Box Gas Panorama 73/52
F
Fig.
NO.
Ontop Art./
ORDER
NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
21 USAB 10 Cover band, screw-fastening. ●●
23 USMB 10 Wall strap, adjustable. ●●
23 USEB 10 Fitting bracket. ●●
24 USCP 10 Set of ceiling finishing plates /
Fire stops / Centring plates. ●●
24 USDQ 10 Roof support. ●●
25 USSAN 10 Renovation set. ●●
25 USSAN1 10 Top of renovation set. ●●
25 USSAN2 10 Bottom renovation set. ●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
31
F
Fig.
NO.
Ontop Art./
ORDER
NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
28 USKBS 10 Locking band, screw-fasten-
ing. ●●
USI 10 Concentric pipe with inspec-
tion panel, L= 250 mm. ●●
34 USEM 10 Concentric pipe with gauging
orifice, L= 150 mm. ●●
35 USBI 10 90° concentric bend with in-
spection panel. ●●
USR 10 Rosette smooth Ø150 mm. ●●
USMPG 10 Wall plate large Ø150 mm,
square 300 mm. ●●
USAH 10 Spacer bracket. ●●
USVG 10 13
Concentric reduction of
Ø100-Ø150 mm → Ø130-
Ø200 mm.
●●
Available components for the concentric flue
system
32
Box Gas Panorama 73/52
6
6.5 Jeremias/STB - H-Twin system Ø100 - Ø150
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
11 ATWINL 13
100-150
Twin-wall balanced flue pipe.
L= 1000 mm. ●●
10 ATWINL 14
100-150
Twin-wall balanced flue pipe.
L= 500 mm. ●●
10 ATWINL 15
100-150
Twin-wall balanced flue pipe.
L= 250 mm. ●●
12 H-TWIN 742
100-150
Telescopic twin-wall balanced
flue pipe, L= min. 1100 / max.
1400 mm.
●●
12 H-TWIN 467
100-150
Telescopic twin-wall balanced
flue pipe, L= min. 1100 / max.
1900 mm.
12 ATWIN 197
100-150
Telescopic twin-wall balanced
flue pipe, L= min. 600 / max.
900 mm.
15 ATWIN 16
100-150
Twin-wall balanced flue el-
bow 15°. ●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
33
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
15 ATWIN 17
100-150
Twin-wall balanced flue el-
bow 30°. ●●
15 ATWIN 18
100-150
Twin-wall balanced flue el-
bow 45°. ●●
14 ATWIN 60
100-150
Twin-wall balanced flue el-
bow 90°. ●●
14 ATWIN 60F
100-150
Twin-wall balanced flue el-
bow 90° - Short. Especially
for connection to a wall termi-
nation.
●●
16 A 463
100-150
Roof termination - long, with
pipe, L = 1080 mm, Vertical. ●●●
Available components for the concentric flue
system
34
Box Gas Panorama 73/52
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
16 ATWIN 92
100-150
Roof termination - short with
pipe, L = 300 mm, Vertical. ●●●
32
ATWIN
92pe
100-150
Roof termination, with pipe, L
= 495 mm, Vertical, with roof
flashing for existing chimney
or flat roof.
●●●
17
ATWIN
45DD
100-150
Roof flashing for roof pitch
30°, with lead flashing and
storm collar.
●●●
17
ATWIN
60DD
100-150
Roof flashing for roof pitch
45°, with lead flashing and
storm collar.
●●
ATWIN 307
100-150 Storm collar. ●●
24 ADBL-DW
100-150
Set of ceiling finishing plates /
Fire stops. ●●
20 ATWIN 45
100-150
Locking band, Screw-fasten-
ing (Standard on all compo-
nents).
●●
23 ATWIN 22
100-150 Wall strap, adjustable. ●●
23 ATWIN 23
100-150
Wall strap, distance adjusta-
ble 60-250 mm. ●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
35
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
19 A681
100-150
Horizontal (wall) termination
kit, L= 495 mm (horizontally
adjustable), including one set
of wall spacer plates.
●●
33 H-TWIN 752
100-150
Concentric T-piece with
gauging orifice. Inspection
panel with cover cap and
condensation-opening.
●●
ATWIN 465
100-150
Adapter: H-TWIN Ø100-150
→ Flex Stainless steel ; Ø100
mm Incl. Ceiling plate
300x300 mm.
●●
ATWIN 466
100-150
Adapter: Flex Stainless steel;
Ø100 mm → H-TWIN
Ø100-150 Incl. Chimney(ceil-
ing)plate 300x300 mm.
●●
36 ASDH2
100-150
Universal wall / floor support
Ø150 mm. ●●
100 A464 130
Concentric reduction of H-
TWIN Ø130 / Ø200 mm → H-
TWIN Ø100 / Ø150 mm.
●●
Available components for the concentric flue
system
36
Box Gas Panorama 73/52
6
6.6 Jeremias - TWIN-GAS system Ø100 - Ø150
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
TWG1634
100-150
Bellfires Appliance connec-
tion / Adapter Bellfires
Ø100/150 mm → Jeremias
TWIN-GAS Ø100/150 mm L
= 160 mm Including locking
band (2x).
●●
11 TWG13
100-150
Twin-wall balanced flue pipe,
L = 1000 mm Including lock-
ing band.
●●
10 TWG14
100-150
Twin-wall balanced flue pipe,
L = 500 mm Including locking
band.
●●
10 TWG15
100-150
Twin-wall balanced flue pipe,
L = 250 mm Including locking
band.
●●
TWG1801
100-150
Twin-wall balanced flue pipe,
L = 1000 mm with 4 spacer
brackets on the outside In-
cluding locking band.
●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
37
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
12 TWG50
100-150
Telescopic twin-wall balanced
flue pipe, L= min. 330 / max.
420 mm Including locking
band.
●●
15 TWG16
100-150
Twin-wall balanced flue el-
bow 15°. Including locking
band.
●●
15 TWG17
100-150
Twin-wall balanced flue el-
bow 30°. Including locking
band.
●●
15 TWG18
100-150
Twin-wall balanced flue el-
bow 45°. Including locking
band.
●●
14 TWG60
100-150
Twin-wall balanced flue el-
bow 90°. Including locking
band.
●●
14 TWG1786
100-150
Twin-wall balanced flue el-
bow 90° - with support leg In-
cluding locking band and
sealing cap under.
●●
14 TWG1676
100-150
Twin-wall balanced flue el-
bow 90° - short - eccentric.
Especially for connection to a
wall termination TWG1619 In-
cluding locking band.
●●
Available components for the concentric flue
system
38
Box Gas Panorama 73/52
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
16 TWG272
100-150
Roof termination (vertical) L=
615 mm. Including locking
band.
●●
17 TW53 150
Roof flashing with a roof pitch
of 5° - 15° With flex alu-flash-
ing and storm collar.
●●
17 TW59 150
Roof flashing with a roof pitch
of 16° - 25° With flex alu-
flashing and storm collar.
●●
17 TW38 150
Roof flashing with a roof pitch
of 26° - 35° With flex alu-
flashing and storm collar.
●●
17 TW54 150
Roof flashing with a roof pitch
of 36° - 45° With flex alu-
flashing and storm collar.
●●
18 TW52 150
Roof flashing for existing
chimney or flat roof With
storm collar.
●●
KL72 150 Storm collar (spare part). ●●
19 TWG1619
100-150
Wall termination kit, L= 600
mm (horizontal) Adjustable.
Incl. locking band and one set
of wall spacer plates.
●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
39
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
20 TW45 150 Locking band, screw-fasten-
ing (spare part). ●●
21 ALBI26 150 Silicone sealing ring for outer
pipe (spare part).
23 ZUWA704
150
Wall strap. Distance to the
wall: WA= 50 mm. ●●
ZU-
WA891130
Extension pieces for the wall
strap ZUWA704 L= 130 mm. ●●
ZU-
WA891200
Extension pieces for the wall
strap ZUWA704 L= 200 mm. ●●
ZU-
WA891250
Extension pieces for the wall
strap ZUWA704 L= 250 mm. ●●
ZUWA706
Extension pieces for the wall
strap ZUWA704 L= 400 mm,
WA = 50 - 360 mm.
●●
24 ZUDA074
150
Set of ceiling finishing plates /
Fire stops for a flat roof : 0°. ●●
24 ZUDA99V
150
Set of ceiling finishing plates /
Fire stops for a pitched roof :
0° - 30°.
●●
24 ZUDA98V
150
Set of ceiling finishing plates /
Fire stops for a pitched roof :
31° - 45°.
●●
Available components for the concentric flue
system
40
Box Gas Panorama 73/52
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
24
ZU-
DA99VHL
150
Set of ceiling finishing plates /
Fire stops with ventilation
openings for a pitched roof :
0° - 30°.
●●
24
ZU-
DA98VHL
150
Set of ceiling finishing plates /
Fire stops with ventilation
openings for a pitched roof :
31° - 45°.
●●
25 FD08 100
Adapter: TWIN-GAS to FLEX.
(only for the inner pipe Ø100
mm).
●●
25 TWG1276D
100-150
Chimney-/flat roof-/ceiling -
plate with adapter: FLEX to
TWIN-GAS.
●●
25 ZUWA1618
100
Adapter: TWIN-GAS to
‘Schaft’ (DE). ●●
25 TWG1732
100-150
Chimney-/flat roof-/ceiling -
plate with adapter: Ø100 rig-
id/flex to TWIN- GAS .
●●
33 TWG317
100-150
Concentric T-piece 90°. In-
cluding locking band. ●●
34 TWG51
100-150
Concentric pipe with gauging
orifice L= 200 mm. Including
locking band.
●●
35 TWG10
100-150
Concentric pipe, L= 300 mm
with cleaning opening/inspec-
tion panel. Including locking
band.
●●
35 TWG19
100-150
Concentric elbow 90° with
cleaning opening/inspection
panel. Including locking band.
●●
Available components for the concentric flue
system
Box Gas Panorama 73/52
41
F
Fig.
NO.
Jeremias
Art./ OR-
DER NO.
DESCRIPTION
Color (*) Application
rvs antr. rigid flex
36 TWG05
100-150
Base plate/Cover-under with
2x ½” gauging orifice, sealing
cap and condensate drain at
the bottom.
●●
36 TWG07
100-150 Base plate / floor support. ●●
DW391
Wall support with transverse
support Type I: 350 mm - Dis-
tance to wall: WA= max. 50
mm.
●●
DW392
Wall support with transverse
support Type II: 500 mm -
Distance to wall: WA= 50 -
150 mm.
●●
DW393
Wall support with transverse
support Type III: 750 mm -
Distance to wall: WA= 150 -
250 mm.
●●
DW407
Wall support with transverse
support Type IV: 1030 mm -
Distance to wall: WA= 250 -
360 mm.
●●
(17-
24)
LUX-ECO
150
Insulation roof flashing, L=
Max. 500 mm (adjustable).
Wall thickness LUX-ECO In-
sulation: min. 25 mm.
(19) LUX-ECO
150
Insulation wall flashing, L=
Max. 360 mm (adjustable).
Wall thickness LUX-ECO In-
sulation: min. 25 mm.
Available components for the concentric flue
system
42
Box Gas Panorama 73/52
Available components for the concentric flue
system
Box Gas Panorama 73/52 4
43
Y
Your Bellfires dealer
001 - 29.11.2018 - 348035
37

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bellfires Box Gas Panorama 73-52 MF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bellfires Box Gas Panorama 73-52 MF in de taal/talen: Engels als bijlage per email.

De handleiding is 1.42 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Bellfires Box Gas Panorama 73-52 MF

Bellfires Box Gas Panorama 73-52 MF Aanvulling / aanpassing - Nederlands - 44 pagina's

Bellfires Box Gas Panorama 73-52 MF Installatiehandleiding - Nederlands - 52 pagina's

Bellfires Box Gas Panorama 73-52 MF Gebruiksaanwijzing - Nederlands - 32 pagina's

Bellfires Box Gas Panorama 73-52 MF Aanvulling / aanpassing - Deutsch - 44 pagina's

Bellfires Box Gas Panorama 73-52 MF Installatiehandleiding - Deutsch - 56 pagina's

Bellfires Box Gas Panorama 73-52 MF Gebruiksaanwijzing - Deutsch - 32 pagina's

Bellfires Box Gas Panorama 73-52 MF Installatiehandleiding - English - 48 pagina's

Bellfires Box Gas Panorama 73-52 MF Gebruiksaanwijzing - English - 32 pagina's

Bellfires Box Gas Panorama 73-52 MF Aanvulling / aanpassing - Français - 44 pagina's

Bellfires Box Gas Panorama 73-52 MF Installatiehandleiding - Français - 52 pagina's

Bellfires Box Gas Panorama 73-52 MF Gebruiksaanwijzing - Français - 32 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info