ENGLISH
Warning:
- The smokemachine must be placed at least 100 cm away from inflammable materials such as curtains, books,
etc. Make sure that the housing cannot be touched by accident.
- For indoor use only.
- During installation, nobody should stand beneath the mounting area.
- Prior to the first use, have the unit checked by a qualified person.
- The unit contains voltage carrying parts. DO NOT open the smokemachine
- Never plug or unplug the unit with wet hands.
- If the plug and/or mains lead are damaged, they need to be repaired by a qualified technician.
- If the unit is damaged to an extent that you can see internal parts, do not plug the unit into a mains outlet. It
needs to be repaired by a qualified technician.
- Only connect this unit to an earthed mains outlet of 230Vac/50Hz .
- Always unplug the unit during a thunderstorm or when it is not in use.
- If the unit has not been used for a longer period of time, condensation can occur inside the housing. Please let
the unit reach room temperature prior to use.
- When you unplug the unit from the mains always pull the plug, never the lead.
- In order to prevent dropping of the unit, a safety fastening needs to be installed. This can be a solid chain, a steel
cable, etc. which has to be fastened separately from the mounting bracket.
- The supplied bracket is the main fixing and must be used to solidly mount the light effect.
- In order to avoid accidents in public premises, the local legal requirements and safety regulations/warnings must
be fulfilled.
- Keep out of the reach of children.
Safety
Plug the smoke machine only in an earthed mains outlet or extension cord! ATTENTION: the powercord can only be
replaced by an original replacement, supplied by Tronios.
Be careful when filling the fluid tank. First of all, unplug the mains lead! Then unscrew the cap on the tank and fill it by
means of a funnel.
Only use the original Beamz smoke fluid which is environmental friendly and, if used correctly, leaves no residues.
Do not obstruct the openings on top of the case to guarantee a good ventilation. The heating element of the smoke
machine generates heat which needs to be removed. Don’t put any objects on the smoke machine.
Installation and Use
Unpack the fog machine. Do not connect yet the net cable. Connect the remote control to the connector on the back of
the fogger. Fill the fluid tank by means of a funnel. Plug the unit into a mains outlet. Thus the heating element is
automatically switched on. Depending on the room temperature, it takes about 8 minutes until the working temperature is
reached. Then the thermostat is clicking and the LED on the manual control lights up.
Push the switch once and the smoke machine will produce a nice thick fog. Once the smoke machine has reached its
working temperature (the LED is lit) the smoke machine can produce continuously fog during max 1 minute.
After this period of time, the fog generator is cooled so much down that the thermostat switches off. Wait a few minutes
until the working temperature is reached again. It is recommended to produce smoke with small pauses in between so that
the temperature is maintained and the thermostat doesn’t switch off.