7
Operation and Programming
Start / Stop / Tare
Press this button to start the grinder
(after selecting a preset button (1,2 or
3). The grinder will stop automatically
when the pre-programmed weight has
been ground. If you’d like to stop the
grinder sooner, press the button again.
To TARE (zero) the unit, rst make
sure the grounds bin is totally empty
and properly inserted on the weigh
platform. Press and hold the TARE
button for 3 seconds, then release.
The display will then read 00.0.
Up / Down Arrow
Press either of these buttons to set
the weight value (in grams), displayed
in the LCD window
Programmable Dosage
Buttons 1 - 2 - 3
Each of these buttons can store a
programmable weight value. Simply
press the up or down arrow to select
the number of grams you desire, then
press and hold the button (1,2 or 3)
you want the displayed weight stored
to. As soon as the display blinks,
release the selected button (the new
value is now stored in Non-volatile
memory. Repeat for each of the three
buttons. The programmed weights will
remain stored in memory even if the
ESATTO
TM
is unplugged. If you adjust
the desired weight for any button
(1,2 or 3) but do NOT press and hold
the button, the new weight will be
displayed and temporarily stored in
volatile memory, however, if the Esatto
is unplugged, the new value will be
“forgotten”.
Calibration
On occasion it may be helpful to
recalibrate your Esatto. To do so, you
will need a 200 gram weight. (If you
don’t have a 200 gr weight, you can
“create” your own if you have another
accurate gram scale as follows: Place
the Esatto grounds bin on your gram
scale and ll it with water until it totals
200 grams (bin +water)). You are now
ready to do the calibration routine:
Make sure the grounds bin is re-
moved. Press and hold the START/
stop button for 3 seconds, then
release. This causes a reboot of the
Esatto. During the reboot, press and
hold buttons 1&2. The display will
come up with a value (approx 310-
350). Release buttons 1 &2. Press
button 1 again, “CAL” will briey show
in the display, then “200”, GENTLY
set the 200 gr weight on the platform.
Display will show “pas” and then show
“200”. Calibration is now complete.
Prior to use, you will need to TARE
with the empty grounds bin in place on
the weigh platform to “zero” the bin.