3. Initial Operation, Using the Stove
First steps:
1. The stove must be connected to the flue. There must be a sufficient supply of combustion air.
2. Remove the accessories from the pellet hopper and the firebox. Fill the hopper with pellets and close
the hopper lid.
3. Plug in the power cable and set the toggle switch on the back of the stove to "I ".
4. The display will now show the Austroflamm logo. This is followed by the main operating menu with
temperature indicators and hopper level.
5. Before the initial start, the pellet worm conveyor must be filled. To do this, open and close the fire-
box door. (Confirm the subsequent question on the display: “Have you inserted firewood?” with
“YES”.) Next, start the manual filling process. For more detailed information, see the menu item: Man-
ual pellet feed. This process takes about 5 minutes.
6. To start the stove in pellet mode, press the rotary knob for longer than 2 seconds or press “START”
on the display.
3.1. Operating the stove via touch display
Display − Room temperature indicator, various functions
By pressing the appropriate symbol, it is possible to switch to the desired setting or function.
The desired temperature can be set by pressing the buttons at 0.2 °C intervals between 5 °C and
40 °C. The setting is accepted immediately. The current room temperature is measured Standard
necessary by the black, room- temperature sensor cable on the back of the appliance.
The warning or error icons appear only when a warning or error is detected. The error is displayed
in detail by touching the icon.
The icon "Heating time activated" is only displayed if heating times are programmed in the timer
menu.