719590
13
Verklein
Vergroot
Pagina terug
1/18
Pagina verder
USER INSTRUCTIONS
Reset/Diagnostics
When one of the malfunctions described above occurs, the appliance will enter its “fault status” and all LEDs on the
control panel will ash simultaneously.
Reset: to reset the appliance, switch the product o and on again using the
button (Ref. A). If the cause of the mal-
function disappears immediately following the reset process, the appliance will resume normal operation. If this is not
the case, all the LEDs will continue to ash; contact the Technical Assistance Centre.
Diagnostics: to enable the diagnostic function, hold the
button (Ref. A) for 5 seconds. The type of fault is indicated
by ve LEDs (Ref. 1 >5) according to the following scheme:
LED Ref. 1 – Internal P.C.B. malfunction;
LED Ref. 2 – Anode malfunction (in models tted with active anode);
LED Ref. 3 – NTC 1/NTC 2 temperature sensors broken (open or short-circuited);
LED Ref. 5 – Water overheating detected by an individual sensor;
LEDs Ref. 4 and 5 – General overheating (P.C.B. malfunction);
LEDs Ref. 3, 4 and 5 – Operation without water.
Exit the diagnostic function by pressing the
button (Ref. A) or wait for 25 seconds.
"Thermal disinfection cycle" function (anti-legionella)
The anti-legionella function is activated by default. It consists of a heating/maintenance cycle of the water at 60°C for 1h
so as to carry out thermal disinfection action against the relevant bacteria.
The cycle starts at the rst ignition of the product and after each re-ignition which follows a lack of mains power. If the
product always work at a temperature below 55°C, the cycle is repeated after 30 days. When the product is o, the anti-
legionella function is not active. If the appliance is switched o during the anti-legionella cycle, the product turns o
and the function is not completed. At the end of each cycle, the operating temperature returns to the value set previ
-
ously by the user. The activation of the "anti-legionella cycle" is displayed as a normal temperature setting at 60°C. (Led
Ref. 4). To permanently disable the anti-legionella function simultaneously hold down the "ECO" and "+" buttons for 3
sec.; conrming deactivation the led 40° will C ash rapidly for 4 sec. To reactivate the anti-legionella function, repeat
the operation described above; to conrm the reactivation of the led (Ref. 4) will ash rapidly for 4 sec.
Adjusting the temperature and activating the functions (Fig. 3)
Press the button (Ref. A) to switch on the appliance. Set the desired temperature by using the “+” and “-” buttons to
select a level between 40°C and 65°C. During the heating phase, the LEDs (Ref. 1> 5) corresponding to the temperature
reached by the water so far remain lit in a xed manner; all subsequent LEDs (up to the set temperature) ash progres-
sively. If the temperature drops, for example after hot water has been used, the heating is reactivated automatically and
the LEDs between the last xed light and the light corresponding to the set temperature will resume ashing progres-
sively. The rst time the product is switched on, it will be set to a temperature of 60°C (Led Ref. 4).
In the event of a power failure or if the product is switched o using the button (Ref. A), the most recently set tempera-
ture remains memorised. During the heating phase, a slight noise may be produced as a result of the water heating
process.
The LED remains ON during heating.
ECO FUNCTION
The Eco function is activated/deactivated by pressing the corresponding button. If the function is activated the led will
be switched on. The Eco function aims to produce hot water by learning the user habits. So, for the rst week ever the
product memorises the tappings and the periods in which those tappings take place. From the following weeks the wa
-
ter heating is performed regarding what was learned previously. If the user wants to reset the function and start a new
learning period, it is necessary to press the ECO button for 3 seconds (the eco led will appear blinking).
If during Eco function, PLUS or MINUS button are pressed the function will be deactivated.
SHOWER READY
The Shower Ready LED (B, Fig. 3) indicates whether there is hot water for at least one shower. The quantity of hot water
is determined by internal parameters and varies according to the model.
MAX FUNCTION
The Max function (C, Fig. 3) is activated/deactivated by pressing the corresponding button. If the function is active, the
LED will be lit. The Max function temporarily sets the set-point temperature to 65°C by bypassing the previous operat-
ing mode (if the Eco function is active, the self-learning function is temporarily interrupted and deactivates on its own
once the set-point is reached).
13

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Ariston Pro 1 Eco bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Ariston Pro 1 Eco in de taal/talen: Engels als bijlage per email.

De handleiding is 1,62 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Ariston Pro 1 Eco

Ariston Pro 1 Eco Gebruiksaanwijzing - Nederlands - 16 pagina's

Ariston Pro 1 Eco Gebruiksaanwijzing - Français - 24 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info