water heating will be disabled. The individual “P1” or “P2” programmes are of equal importance and may be congured
independently by the user for greater exibility.
When one of the programming functions (“P1” or “P2” or “P1andP2”) is enabled, the “set” knob is disabled. If it is moved,
“Pr” will appear on the display for 3 seconds. If you wish to adjust the parameters, you will have to press the “set” knob.
ECO PLUS: If one of the programming functions (“P1” or “P2” or “P1andP2”) is used in conjunction with the “ECO EVO”
function (see “ECO EVO function” paragraph), the temperature is set automatically by the appliance. It is therefore only
possible to set the desired time band for hot water availability. If the “set” knob is moved, “PLUS” will appear on the
display for 3 seconds, indicating the simultaneous operation of these two functions.
This operating mode maximises the amount of energy saved.
NB: for any setting, if the user takes no action for 5 seconds, the system saves the last setting.
The LED remains ON during heating.
ECO EVO Function
The "ECO EVO" function consists of self-learning software of the user consumption, which allows heat loss to be mini-
mised and energy savings to be maximised. This function is active by default.
The "ECO EVO" software consists of an initial learning period of a week when the product begins to operate at the tem-
peratureindicatedintheproductdatasheet(AttachmentA)andlogstheuserenergydemand.Fromthesecondweek
onwards the learning process continues so as to learn the user requirements in more detail and changes temperature
every hour to adapt it to the actual demand in order to improve energy savings. The "ECO EVO" software activates the
heating of the water within the time and amounts determined automatically by the product itself according to user con-
sumption. During the day, when no water is drawn, the product still guarantees a reserve of hot water.
Activatethe"ECO"functionbypressingtherelevantkeythatlightsupgreen.
Two operating modes are possible:
1)Manualadjustmentofthetemperature(seethe"Adjustingthetemperatureandactivatingthefunctionsofthedevice"
paragraph): the manual mode is accessed with the ECO button off. In this mode, the product continues to note the user's
energy demand without adjusting the temperature selected by the user. Press the "ECO" key for it to light up and the
"ECO EVO" function to start, which is immediately effective in this case as the "learning process" has already been
implemented;
2) ECO EVO:
- Aftertherstweekofcontinuouslearning,thewaterheateralwayspreparestheamountofhotwateraccordingtoa
statistical prediction of demand which is supplied in time: to do so, the temperature will be automatically determined
which will always be between a Tminimum=40°C and a maximum temperature that is set by the user (by default, the
maximumtemperatureisequaltothevalueshowninthedatasheet[AttachmentA])
- Press the ECO key for long for the eco LED to ash for about 4 s and the learning process restarts (from the rst
week). This is used to delete the user demand from the memory and restart (hard reset).
- Caution: when the ECO key is on and the "+/-" keys (Fig.6) or the knob (Fig.6) or the "ECO" key itself are pressed,
the Eco soft mode described above is accessed (the ECO key goes off)
In order to guarantee proper ECO EVO operation, it is recommended not to disconnect the product from the mains.
EXTRA POWER function
(For models featuring a user interface as represented in gures 4 and 6)
The product usually operates at its basic power level.
TheEXTRAPOWERfunctionactivatesadditionalpowertospeeduptherateatwhichwaterisheated.
To activate it, press the
illuminated button (Ref. B), which will light up in yellow. To deactivate it, press the same
button again; the light will switch off.
Anti-limescale Function
If much limescale is detected, the product switches to limited mode, which is actually "manual" mode with the heating
temperature set to 65°C and the ECO EVO function disabled.
Indication with LED interfaces (Fig. 3): the rst 3 heating LEDs ash simultaneously (Fig. 31;2;3).
Indication with interfaces with display (Fig. 5): on the display the screen alternates between “E70” and “Product
temperature" every 3 seconds, and the heating LEDs ash.
USEFUL INFORMATION
If the water comes out cold, have the following checked:
- the thermostat is powered
- the heating parts of the heating element.
If the water comes out boiling hot (steam in the taps)
Disconnect the appliance from the electricity supply and have the following checked:
25

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Ariston-Blu-Eco-Evo

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Ariston Blu Eco Evo bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Ariston Blu Eco Evo in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools als bijlage per email.

De handleiding is 8,39 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info