DEHUMIDIFIER
LILIUM ART 11 - 13
OPERATING INSTRUCTIONS
Read the instructions carefully before operating or servicing the dehumidifier.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage.
Keep these instructions in a safe place for future reference.
EN
17
V 02/22
The Refrigerant R290
To realize the function of the air conditioner unit, a special refrigerant circulates in the
system. The refrigerant is the fluoride R290 = 3 GWP (Global warming potential). This
refrigerant is flammable and inodorous. It can lead to explosions under certain
conditions, however the flammability of this refrigerant is very low and it can be ignited
only by fire.
Compared to other common refrigerants, R290 is a non-polluting refrigerant with no
harm to the ozonosphere and a no effect upon the greenhouse effect. R290 has very
good thermodynamic features which lead to a really high energy efficiency. The units
therefore need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways other
than those recommended by the manufacturer. Should repair be necessary, contact your
nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be
dangerous. The appliance has to be stored in a room that doesn’t have any continuously
operating ignition sources. (for example: open flames, an operating gas appliance or an
operating electric heater.) Do not pierce or burn.
Appliance has to be installed, used and stored in a room with a floor area larger than 4 m2.
For repairs, strictly follow manufacturer’s instructions only for appliances filled with R290
flammable gas. Be aware that refrigerants do not have any odour.
Appliance is filled with flammable gas R290.
Before installing and using the appliance, read the
owner manual.
Before installing the appliance, read the installation
manual.
Any repairs you need, contact the nearest authorized
Service Centre and strictly follow manufacturer’s
Service Manual.
18
V 02/22
GENERAL OPERATING AND SAFETY INSTRUCTIONS
This appliance is a highly efficient dehumidifier, designed for
domestic use only!
Use this dehumidifier only as outlined in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock or malfunctions.
The unit contains refrigerant; keep it vertical at all times.
Once you have opened the unit, keep it vertical to allow the
refrigerant to stabilise and wait two hours before operating it.
Ensure that the required voltage and frequency
(220-240V/1/50Hz) match the available power source.
This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Make sure the plug is inserted fully. Do not use multiple adapters.
Do not touch the plug with wet hands. Make sure the plug is clean.
Children aged between 3 and 8 years must only be able to turn
the appliance on/off, provided that the appliance has been placed
in its normal operating position, that instructions have been given
on how to use the equipment safely, and that its risks have been
understood.
Children aged between 3 and 8 years must not be able to plug in,
adjust, clean or perform any maintenance on the appliance.
Disconnect the mains power when the appliance is not in use
or during cleaning operations. Keeping the appliance plugged
in may cause electric shocks or accidents.
19
V 02/22
To disconnect the appliance, set the switch to OFF and remove
the plug from the socket. Only pull on the plug. Do not pull the
cord.
Do not bend, drag or twist the cord, or apply force to remove it. Do
not operate the unit if its cable or plug are damaged; doing so
can cause fires or electric shock. If the power cord is damaged,
it must be replaced by a service centre.
Do not place heavy objects on top of the appliance.
To prevent water spills, empty the water tank before moving the
appliance.
Do not tilt the dehumidifier onto one side or turn it upside down, as
the water which runs out could damage the appliance.
Do not operate the unit on unstable or sloping surfaces:
water leaks can cause it to malfunction or cause excessive
vibration and running noise.
The dehumidifier must be positioned at least 50 cm away from the
wall or other obstacles, so that the heat can dissipate correctly.
Close all open windows to maximise dehumidification
efficiency.
Do not insert objects or sharp instruments into the air outlet
grille.
Do not cover the air intake and outlet grilles in any way.
WARNING!
In the event of an anomaly, switch the appliance off and
unplug it immediately. Do not dismantle, repair or modify this
product freely. In the event of a malfunction, contact the after-
sales service centre directly.
Do not immerse the power cord, plug or any other part of the
appliance in water or other liquids.
Do not expose the dehumidifier to direct sunlight.
Keep the appliance well away from sources of heat which could
cause plastic parts to become warped.
20
V 02/22
Do not spray insecticides, oils or paints near the appliance; doing
so may damage its plastic parts or start a fire.
Keep flammable gases and oils away from the appliance!
Do not move the appliance while it is operating; doing so can
cause leaks and malfunction.
In the event of interference with other electrical appliances, place
the two products at a minimum distance of 70cm.
DESCRIPTION OF PARTS
1. Control panel 8. Side panel
2. Colored LED with humidity sensor 9. Air inlet and air filter
3. Front panel 10. Water tank
4. Casters 11. Water outlet
5. Side panel 12. Air outlet
6. Handle 13. Power cord
7. Rear panel
FRONT VIEW REAR VIEW
1
6
3
4
5
2
7 12
10
9
11
13
8
21
V 02/22
The following space must be maintained to ensure the operating efficiency of the dehumidifier.
OPERATING INSTRUCTIONS
APPLIANCE START-UP
Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive
materials and 50 cm away from walls or other obstructions.
Make sure the water tank is in the correct position
.
Connect the power cord to a suitable electric socket (220-240V/1/50Hz).
Turn the appliance on with POWER on the control panel. The unit emits a sound signal and is in standby, the colored
LED on the front panel lights up. The display shows the humidity% detected in the room, therefore set a humidity %
lower than at least 3% compared to that in the room to make the dehumidifier work.
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 35°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running.
The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification
function may intermit: please don’t turn off the switch or pull out the power plug of the dehumidifier.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
Do not remove the tank when the unit is in operation.
If you wish to make continuous draining of condensate, follow the instructions in the dedicated paragraph.
OPERATING PRECAUTIONS
The dehumidifier starts only if the humidity level in the room is higher than 3% the set one.
The dehumidifier will continue to operate until the set humidity level is reached, except for any interruptions due
to filling the tank.
When the water tank is full, the compressor stops running immediately and dehumidification stops; the fan stops after 3
minutes. Empty the tank and reposition it: after carrying out these operations, the unit will start operating again.
ATTENTION:
After each interruption of operation, at least 3 minutes must elapse before the dehumidifier restarts: this start-
up delay protects the compressor from damage.
If, on the other hand, the humidity% set is higher than that present in the room, the dehumidifier will not start.
If, after following the instructions for starting the dehumidifier, the dehumidifier does not start and the (POWER) symbol
does not light up, or the dehumidifier stops without reason, check that the condition of the plug and the power cord are
good. Once this is done, wait 10 minutes and then restart the dehumidifier.
If, even after 10 minutes, the dehumidifier does not start, or if the cable or the plug are damaged, switch off the
dehumidifier and contact a technical assistance center.
WARNING:
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the
room. The room temperature will therefore tend to increase. This is completely normal.
50 cm
50 cm
22
V 02/22
TURNING THE DEHUMIDIFIER OFF
To turn the dehumidifier off press the POWER button. This shuts off power to the unit.
Unplug the appliance if you do not intend to use it for some time.
HOW TO ELIMINATE CONDENSATE
The water extracted from the air can be collected in the provided front tank.
When the tank is full, not inserted or not correctly inserted, the FULL TANK led turns on and the unit beeps for about 10
seconds, at the end of which the unit turns off.
To switch off the appliance, press the POWER button and wait a few seconds.
1. Carefully pull out the tank, following the direction of the arrow.
2. Empty the tank and dry it thoroughly.
3. Reposition the tank
4. Press the POWER button again to turn on the unit.
NB: If the full tank LED remains lit even after emptying the tank, check that the float, which is inside the tank, is correctly
positioned.
Make sure not to damage the float and the locking rivet, which are inside the tank, otherwise the unit will not
automatically stop working when the water tank is full, and the water could leak out and risk wetting the tank. floor and
damage the appliance.
N.B. Do not use the drainage pipe when you want to collect the condensate in the tank, otherwise the water could come
out from the pipe.
CONTINUOUS CONDENSATE DRAINAGE
The water can be continuously drained when using a PVC hose with an inner diameter of 11 mm (supplied).
Turn off the appliance and remove the plug before connecting the hose.
Connect the tube to the condensate drain hole securely and prepare a container that can hold the water. The tube must
be connected without bends or bends, to facilitate an easy drainage of the condensate, and must be positioned at a
greater height than the drain hole.
When disconnecting the hose, prepare a container to collect any residual water that may leak out of the hose.
23
V 02/22
CONTROL PANEL
DISPLAY ON CONTROL PANEL
BUTTONS and LEDs
1. POWER BUTTON: Press this button to turn the dehumidifier on and off. To turn on the dehumidifier, press this button,
the unit emits a beep and is in standby. It works in Auto mode and in high fan speed. The dehumidifier starts to operate
only if the humidity% is lower than that detected in the room (which is shown on the display), then set the desired
humidity level. During operation, the Power symbol on the display remains always on and the display shows the humidity
level detected in the room during operation of the dehumidifier. By pressing this button again, the unit stops working and
the ventilation stops.
2. MODE BUTTON: The unit works in the following circular sequence: Auto Mode -> Continuous Mode -> Sleep Mode,
the corresponding symbols light up on the display according to the selected mode
Auto Mode
Timer
Led Tank full
Child lock
Continuous
Mode Sleep
Mode
POWER
Low fan speed
High fan speed
6 5 4 3 2 1
Display
24
V 02/22
Auto mode: When the humidity in the room is 3% higher than the set one, the ventilation and the compressor start to
work after 3 minutes. On the other hand, when the humidity in the room is 3% lower than the set one, the compressor
stops while the ventilation continues for a short period of time.
In Auto mode it is possible to adjust the ventilation and humidity level.
Continuous mode: The unit works continuously, but it is not possible to adjust the humidity level and ventilation.
Sleep mode: Press the Mode button on the control panel to activate this function, the symbol lights up on the display. If
no selections are made on the control panel within 10 seconds, the display turns off and the fan speed changes from
high to low. To reactivate the lighting, press any button on the control panel. Press the Mode button again to deactivate
this function.
In sleep mode, the fan speed cannot be adjusted but the humidity level can be adjusted.
3. HUM BUTTON (HUMIDITY): press this button to adjust the desired humidity in the room (from 30 to 80%) in steps of
5% By keeping this button pressed for a long time, the humidity level in the room is shown on the display.
4. TIMER BUTTON: allows you to program switching on (if the unit is off) or switching off (if the unit is on) from 0 to 24
hours. Each time the button is pressed, the adjustment interval corresponds to 1 hour, and it is possible to view the time
set on the display, the symbol on the display remains lit during the set time interval. It is always possible to view the set
time by pressing the Timer button, then the display will return to showing the humidity level detected in the environment.
To deactivate the Timer, “00” must appear on the display (flashes 4 times), and the Timer symbol on the display will turn
off.
5. SPEED BUTTON (VENTILATION SPEED): It is possible to adjust the ventilation speed only in Auto mode. Press this
button to adjust the speed from high to low, the corresponding symbols will light up on the display according to the
selection made.
6. LOCK BUTTON: Long press of this button activates the control panel lock function, the corresponding symbol on the
display lights up, and it is no longer possible to make selections on the control panel. Long press this button again to
deactivate this function, the symbol goes off on the display.
When the appliance is switched off, the child lock function is automatically deactivated.
MEMORY FUNCTION: the dehumidifier starts up again after a power failure keeping last settings.
COLOR LED
On the front panel of the dehumidifier there is a LED that shows different colors based on the humidity level detected in the
room:
Blue = Ambient humidity below 45%
Green = Ambient humidity between 45% and 65%
Red = Ambient humidity above 65%
If E0, E2, CL, CH, LO, HI appear on the display on the control panel, the color of the LED will be red.
(for error codes refer to the troubleshooting section).
CLEANING AND MAINTENANCE
MAINTENANCE OF THE HUMIDIFIER’S EXTERIOR SURFACE
Warning
Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric
shock and malfunction.
Warning
Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.
Use a damp and soft cloth to clean the exterior surface of the dehumidifier.
Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage
the surface or colour of the casing.
25
V 02/22
CLEANING THE WATER TANK
We advise removing the tank once every two weeks to prevent mould and bacteria forming on it. Fill the tank with clean
water a small amount of detergent; swill the water around in it, then it out and rinse it thoroughly.
CLEANING THE AIR FILTER
1
The filter is designed to remove dust or dirt from the air.
If the filter is clogged by dust, electricity consumption will be
higher than normal.
Cleaning instructions:
1. Remove the water tank, then remove the filter by
pulling it out from below, following the direction of
the arrow.
Clean the filter by washing it with warm soapy water
DO NOT USE ALCOHOL, BENZENE OR OTHER
AGGRESSIVE PRODUCTS
Allow the filter to dry naturally, then insert it back
into its housing.
Do not use hair dryer or fire to dry the filter
Do not use sponges or brushes to clean the filter as
they can damage it
2. 2. Reposition the filter by inserting it as indicated by
the arrow and replace the water tank.
Do not use the dehumidifier without the filter as dust
may affect the efficiency of the evaporator, resulting
in higher energy consumption.
CONSERVATION AND STORAGE
If the unit is not used for a long period of time, it is necessary to carry out the following operations before storing it.
1. Turn off the device with the Power button and unplug the power cord from the power outlet.
2. Eliminate the water deposited in the water tank and dry it thoroughly
3. Clean the air filter and let it dry completely
4. Place the power cord in the water tank
5. Replace the filter
6. Store the device in an upright position and in a cool, dry and ventilated place.
2
26
V 02/22
TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
SOLUTION
The dehumidifier is not working.
The temperature is above 35 ° C or below
5 °C.
The internal tank is full.
The tank is not positioned correctly.
The humidity in the room is at least 3%
lower than that set
The appliance does not work at these
temperatures
Empty the tank and position the tank
correctly.
Connect the plug.
Set the humidity% lower than 3%
compared to that in the room
The noise suddenly increases
while running
The unit is placed on an uneven surface.
The air filter is clogged
Position the unit on an even and stable
surface.
Clean the filter
Reduced dehumidification effect The filter is full of dust.
The air inlet and outlet are blocked.
Clean the filter.
Remove objects that obstruct the inflow
and outflow of air.
E2 Humidity sensor problem Contact a service center
LO
HI
CL
CH
The humidity present in the environment is
less than 20%
The humidity in the environment is higher
than 90%
Low temperature protection in an
environment below 5 ° C
High temperature protection in the
environment above 38 ° C
The protection system is activated and
the dehumidifier stops
REGULATION (EU) N. 517/2014 - F-GAS
LILIUM ART 11
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0,045 = 0,000135
Tons CO2 equiv.
Do not release R290 into the atmosphere.
LILIUM ART 13
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0,050 = 0,000150
Tons CO2 equiv.
Do not release R290 into the atmosphere.
INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN
DIRECTIVE 2012/19/EU
This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the
crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is
levied for this service), when you purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and
human health resulting from improper scrapping, and also allows the materials from which it is made to be
recovered and recycled, with significant savings in terms of energy and resources.
The so
r
ted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.
27
V 02/22
Specialist’s Manual
Aptitude requirement for maintenance man (repairs. should be done only be specialists).
a) Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate
from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specifìcation.
b) Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring
the assistance of other skilled personnel shall be carried out under the supevision of the person competent in the use of
flammable refrigerants.
Safety preparation work
The maximum refrigerant charge amount is shown on the following table a
(Note: Please refer to the nameplate for the charging quantity of R290)
Room area (m2)
4
11 15
Maximum charge (kg) <0.152 0.225 0.304
table a - Maximum charge (kg)
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the
risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior
to conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being
present while the work is being performed.
General work area
AII maintenance staff and others working in the local area shall be instructed on the nature of work being carried out.
Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the
conditions within the area have been made safe by control of flammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is
aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for
use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
Presence of fire extinguisher
lf any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing
equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work shall use any
sources of ignition in such a manner that it may lead to the risk of fire or explosion. AII possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and
disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area
around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. "No
Smoking" signs shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any
hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should
safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all
times the manufacturer's maintenance and service guidelines shall be followed. lf in doubt, consult the manufacturer's
technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
---The actual refrigerant charge is in accordance with the room size within which the refrigerant containing parts are
installed;
---The ventilation machinery and outlets are operating adequately and are not obstructed;
---lf an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
---Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
---Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance
which may corrode refrigerant containing components, unless the components are constructed of materials which are
inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection
procedures. lf a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until
it is satisfactorily dealt with. lf the fault cannot be corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are
advised.
lnitial safety checks shall include:
---That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
28
V 02/22
---That no live electrical components and wiring are exposed while charging, recovering or purging the system;
---That there is continuity of earth bonding.
Repairs to sealed components
During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked
upon prior to any removal of sealed covers, etc. lf it is absolutely necessary to have an electrical supply to equipment
during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of
a potentially hazardous situation.
Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not
altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of
connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that the apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of
preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's
specifications.
NOTE: The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment. lntrinsically
safe components do not have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the
permissible voltage and current permitted for the equipment in use.
lntrinsically safe components are the only types that can be worked on while live in the presence of a flammable
atmosphere. The test apparatus shall beat the correct rating.
Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in
the atmosphere from a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other
adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A
halide torch (or any other detector using a naked flame) shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for all refrigerant systems.
Electronic leak detectors may be used to detect refrigerant leaks but, in the case of flammable refrigerants, the sensitivity
may not be adequate, or may need re-calibration.
(Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of
ignition and is suitable for the refrigerant used.
Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the
refrigerant employed, and the appropriate percentage of gas (25 % maximum) is confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chiarine shall be
avoided as the chiarine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked
flames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or
isolated (by means of shut off valves) in a part of the system remote from the leak. For appliances containing flammable
refrigerants, oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing
process.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be
used. However, for flammable refrigerants it is important that best practice is followed since flammability is a
consideration. The following procedure shall be adhered to:
• remove refrigerant;
purge the circuit with inert gas; evacuate;
purge again with inert gas;
open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders.
For appliances containing flammable refrigerants, the system shall be flushed with OFN to render the unit safe. This
process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant
systems.
For appliances containing flammable refrigerants, flushing shall be achieved by breaking the vacuum in the system with
OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to
a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used,
the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital
if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and that ventilation is available.
Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed.
29
V 02/22
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or
lines shall be as short as possible to minimise the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete (if not already).
- Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas.
The system shall be leak-tested on completion of charging but prior to commissioning. A follow up leak test shall be
carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its
detail. lt is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil
and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. lt is essential
that electrical power is available before the task is commenced.
a. Become familiar with the equipment and its operation.
b. Isolate system electrically.
c. Before attempting the procedure, ensure that:
mechanical handling equipment is available, if required, for handling refrigerant cylinders;
all personal protective equipment is available and being used correctly;
the recovery process is supervised at all times by a competent person;
recovery equipment and cylinders conform to the appropriate standards.
d. Pump down refrigerant system, if possible.
e. lf a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the
system.
f. Make sure that cylinder is situated on the scales before recovery takes place.
g. Start the recovery machine and operate in accordance with manufacturer's instructions
h. Do not overfill cylinders. (No more than 80 % volume liquid charge).
i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
j. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the
equipment are removed from site promptly and all isolation valves on the equipment are closed off.
k. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be
dated and signed. For appliances containing flammable refrigerants, ensure that there are labels on the equipment
stating the equipment contains flammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that
all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
Ensure that the correct number of cylinders for holding the total system charge are available. AII cylinders to be used are
designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of
refrigerant). Cylinders shall be complete with pressure-relief valve and assodated shut-off valves in good working order.
Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at
hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable
refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be
complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is
in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to
prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant
waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
lf compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to
make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out
prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to
accelerate this process. When oil is drained from a system, it shall be carried out safely.
www.argoclima.com
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Argo LILIUM ART 11 - 13 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Argo LILIUM ART 11 - 13 in de taal/talen: Engels als bijlage per email.

De handleiding is 0.86 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Argo LILIUM ART 11 - 13

Argo LILIUM ART 11 - 13 Gebruiksaanwijzing - Deutsch - 15 pagina's

Argo LILIUM ART 11 - 13 Gebruiksaanwijzing - Français - 16 pagina's

Argo LILIUM ART 11 - 13 Gebruiksaanwijzing - Italiano - 15 pagina's

Argo LILIUM ART 11 - 13 Gebruiksaanwijzing - Português - 15 pagina's

Argo LILIUM ART 11 - 13 Gebruiksaanwijzing - Espanõl - 14 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info